Basic IC Fittings and Tubings

This article contains images of commonly used IC parts.

Description: 

The table below is an illustrated parts list for Ion Chromatography products.

Environment:

Ion Chromatography

 

Part Description PN Common Uses Image
Bolt Blue double cone ferrule bolt, 10- 32 074449 High-pressure connections
to 1/16 in. tubing (columns, suppressors, etc.)
074449_Fitting_blue_HP.png
Ferrule Double cone ferrule, 10-32 074373   074373 blue ferrule.png
Bolt ¼-28 for 1/8 in. tubing Natural PEEKTM 052267 Connect eluent supply and waste lines 052267 1_8 fitting bolt.jpg
Bolt ¼-28 for 1/8 in. tubing Natural PEEKTM, short length 057934 Regen IN tubing connection
on CR-TC, AS-AP syringe valve connection
057934 short 1_8 fitting bolt.jpg
Ferrule 1/8 in. (yellow, reverse type) 048949   048949.png
Bolt (long) ¼-28 for flat fitting, 1/16 in. tubing 052230 Connect 1/16 in. tubing to regen circuit of CR-TC, suppressor (use green PEEK tubing only) 052230 1_16 fitting bolt.jpg
Ferrule Flat type reverse, 1/16 in. (for bolt above) 052231   052231 ferrule.png
Bolt (short) ¼-28 for flat fitting, 1/16 in. tubing 071358 Connect 1/16 in. tubing to AS-AP syringe valve 071358_short bolt.jpg
Ferrule Two-piece, clear cone and tan flat 062511 Connect 1/16 in. tubing to AS-AP syringe valve, pump mixing valve, pump degasser and primary pump head 062511_2 pc ferrule.jpg
Union ¼-28 to ¼-28, 0,06 in. through hole (female threaded for male connector) 039056 Connect 1/8 in. tubing pieces together 039056 tan coupler.jpg
Union ¼-28 to 10-32 (female threaded for male connector) 042806 Join 1/8 in. and 1/16 in.
tubing together
042806.png
Union 10-32 to 10-32 (female threaded for male connector) 042627 Join 1/16 in. and 1/16 in.
tubing together
042627 black union.jpg
Syringe Adapter Female Luer to male thread ¼-28 024305 Connect syringe to 1/8 in. tubing (with ¼-28 to ¼-28 union and male fittings) 024305 luer adapter.jpg
Syringe Adapter Female Luer to male thread 10- 32 046888 Connect syringe to 1/16 in. tubing 046888.jpg
Plug 10-32 042772 Plug columns, eluent connection on CR-TC and suppressors 042772 black plug.png
Plug ¼-28 037628 Plug regen side of suppressors and CR-TC 037628.jpg
Plug ¼-28 045597 Cap 1/8 in. tubing for eluent supply line and regen lines 045597 (2).png
Bolt   22000-98001 High-pressure connections to 1/16 in. tubing (columns, suppressors, etc.). 22000-98001 tan bolt.png
Ferrule each 043276 Tan double-cone ferrule 043276 tan double cone ferrule.jpg
Ferrule pack of 10 043225 Tan double-cone ferrule  
Yellow PEEK 20 ft (0.003 in. i.d.) 052300 Backpressure coils 052300 yellow peek.jpg
Red PEEK 20 ft (0.005 in. i.d.) 052311 Backpressure coils and microbore (2 mm column) plumbing 052311 red peek.png
Black PEEK 20 ft (0.010 in. i.d.) 052307 Standard (4 mm column) tubing 052307 black PEEK.png
Blue PEEK 20 ft (0.013 in. i.d.) 052302 AS-AP transfer line tubing 052302 blue peek.jpg
Orange PEEK 20 ft (0.020 in. i.d.) 052308 Waste lines, sample loops 052308 orange PEEK.png
Green PEEK 20 ft (0.030 in. i.d.) 052304 Waste lines, sample loops 052304 green peek.png
Tan PEEK 0.040 in. i.d. (per inch) 054410 Pump tubing 054410 tan PEEK.png
PTFE (low pressure tubing) 1 in (1/8 in. o.d.) 014157 Eluent supply and waste lines 014157.png
10 ppm Nitric Acid 50 mL 052820 Basic system functionality testing (CD) 052820 10ppm nitric acid.jpg
Seven Anion II 100 mL 057590 F (20), Cl (100), NO2 (100),
Br (100), NO3 (100), PO4
(200), SO4 (100)
057590 seven anion standard.jpg
Six Cation II 50 mL 046070 Li (50), Na (200), NH4 (250), K
(500), Mg (250), Ca (500)
Dionex™ Combined Six Cation Standard-II
Plasting Tubing Cutter   049584   049584 tubing cutter.png
J-Clip J-clip bracket 074976 AS-AP needle alignment 074976 J clip.png
Syringe, 1mL   016388   016388 1ml syringe.jpg
Syringe, 10mL   079803   079803_10ml syringe.jpg

 

 

 