Introduction to workflows

What are workflows?

Workflows in OMNIC Paradigm are automated sequences of software operations designed to standardize and streamline routine tasks. They are represented by tiles that you can drag and drop onto a workflow canvas, allowing you to automate data collection, processing, reporting, and archiving with a single click.

Benefits of workflows

Workflows are invaluable for ensuring consistency and efficiency in repetitive tasks. By using workflows, operators can perform complex procedures with precision, reducing the risk of human error and saving time. They simplify routine processes, ensuring that measurements are collected and processed consistently every time.

Creating a workflow

Create a workflow from scratch
 To create a workflow from scratch
  1. From the OMNIC Paradigm dashboard, go to File > workflow > Create.

    image2.png
  2. Name your workflow and click OK.

  3. In the workflow Editor, start by dragging a Measure tile to the canvas to automate data collection.

  4. Add the Processing tile to add a processing action, such as Baseline Correction, to correct or improve your data before analyzing it.

  5. Add an analysis tile, like Search, to analyze your spectrum.

  6. Finally, add a Template Report tile to generate and save a report.

Create a workflow from an existing measurement

Alternatively, you can create a workflow from an existing measurement. This choice automatically creates a workflow and adds steps based on the workflow history. For example, if you measured a sample, performed baseline correction, and then did a correlation search, the workflow will automatically include Measure, Processing, and Search tiles.

Note that this method does not automatically include the Report tile. You must add that after creating the workflow.

 To create a workflow from a measurement
  1. From the OMNIC Paradigm dashboard, right-click your measurement and select Open In > New Tab.

  2. Select the spectrum and navigate to History.

  3. Select Create Workflows.

  4. Enter a name for the workflow and choose either a standard workflow or a tab-ready workflow. For now, choose Create standard workflow.

  5. Your new workflow opens in the Workflow Editor. The workflow includes the measure tile with the settings used for this measurement and any needed processing or analysis tiles.

Edit an existing workflow

  1. From the Workflow Pane, right-click the workflow you wish to edit and select Edit.

    image5.png
  2. Modify the existing tiles or add new ones as needed.

  3. Save your changes.

Run a workflow
  1. From the Workflow Pane, right-click the workflow and select Run.

    image6.png
  2. Follow the prompts in the Run Workflow window to complete the tasks.

Workflow actions

Workflow tiles can be grouped into a few categories of actions. These categories align with the same general steps for working with spectra.

image7.png

In addition to these high-level groups, you can use tiles to communicate with the operator running the workflow, control the flow of the workflow, and use advanced techniques.

Refer to the Workflow Tiles Reference for a detailed description of all options for each tile.

Collect or import data

Most workflows require spectral data for processing or analysis. You can either measure new data as part of the workflow or import existing measurements.

Tile   Use to …

Measure

image8.png

Measure a sample and collect new data. This tile can be used to measure a background, a sample measurement, or both.

Load Spectrum

image9.png

Use this tile to load spectra into the workflow. These can be from your database or from a file.

Process

Workflows can process spectra using many of the same processing operations found throughout OMNIC Paradigm software.

Tile   Use to …

Spectral Metadata

image10.png

With this tile, you can read or change spectral metadata, such as the spectrum title, comments, and tags.

Advanced Spectral Math

image11.png

Use advanced spectral math with custom equations.

Processing

image12.png

This tile includes operations such as baseline correction, basic spectral math, data smoothing, and more.

Tag measurement

image13.png

Use this tile to add tags to your measurements.

ATR Correction

image14.png

Use this tile to correct data that was collected with an ATR accessory.

Analyze

Use analysis tiles to find out information about your measurements.

Tile   Use to …

Search

image15.png

Use the search tile to identify samples, sample components, and contaminants.

TQ Analyst

image16.png

Use the TQ Analyst tile to apply quant methods created in TQ Analyst software.

QCheck

image17.png

Use the QCheck tile to compare your sample spectrum to a known reference spectrum.

Peak Analysis

image18.png

With this tile, you can measure peak height or area or find the location of peaks within a region.

Report

Use these tiles to create reports and save or export data.

Tile   Use to …

Report

image19.png

Create a custom report.

Template Report

image20.png

Create a report using a template.

Export

image21.png

Export reports and spectral data to a file outside of the database. Measurements and reports created in the workflow are automatically saved to your database.

Save Results

image22.png

Save results, such as search results or peak values, to a CSV file.

Other types of workflow actions

Other tiles are used for controlling the flow of your workflow or communicating with the operator who is running the workflow.

Conditions and flow

With these tiles, you can control which steps are carried out in the workflow. For example, use a Decision tile to choose one path if a TQ check fails and another if the check passes.

Tile   Use to …

Decision

image23.png

Create branches in the workflow based on conditions. For example, use this tile to check if a QCheck test passed, then continue to the finish if the check passed or return to the start to measure and analyze again before continuing.

Repeat

image24.png

Repeat a section of the workflow a pre-set number of times.

Delay

image25.png

Enforce a wait period. For example, this may be useful to force the operator to wait for the instrument to stabilize before allowing the next steps.

Start and End

image26.png

image27.png

Set the beginning and end of the workflow.

Communicate with the operator
Tile   Use to …

Instruction

image28.png

Communicate with the operator. Enter custom instructions and attached images and PDFs. For example, use this tile to provide information on how to prepare the sample for measurement.

Selection

image29.png

Create branches in the workflow based on the operator’s choice.

Advanced options

These tiles can add significant control and complexity to your workflow and are likely to be used only in advanced applications.

Tile   Use to …

Variable

image30.png

Create or change variables in the workflow.

For more information, review Variable tile on the knowledge base.

List

image31.png

Create or use lists of items, such as a list of spectra. This tile is often used with the Repeat tile to loop through a section of the workflow.

For more information on using this tile, review Working with Lists in Workflows on the knowledge base.

Equation

image32.png

Create custom equations using many built-in functions. Read

Create an equation for an explanation of the available functions.

Workflow Table

image33.png

With the Workflow Table tile, you import a table of options and corresponding values from a CSV file. Then, use the values throughout the workflow.

With a Workflow table tile, you can …

  • import many files and variables at once.

  • allow the operator to select from a list of options or automate the choice.

  • import custom variables or reference external files, such as images or QNT files.

For instructions on using this tile to create a template workflow, review Create a Template Workflow on the knowledge base.

Embedded Workflow and Sub Workflow

image34.png

image35.png

With the Sub Workflow and Embedded Workflow tiles, you can run another workflow as a part of a larger workflow. Sub and embedded workflows are regular workflows run as a step during another workflow. This is useful for keeping your workflows organized and easy to manage. For example, you might create a small workflow to perform a few processing or analysis steps, then reuse it in several other workflows. When you need to update the workflow, you can make any desired changes in one place only and then update all the workflows where it is used.

With the Sub Workflow tile, you can send data from the main workflow to the sub workflow, and you can choose which data you get back.

On the other hand, when using the Embedded Workflow tile, data is only sent in a single direction: from the embedded workflow to the main workflow. You cannot choose which data to get back with an embedded workflow; you will get every variable created for it.

Read Using Sub Workflow and Embedded Workflow Tiles on the knowledge base for more information on when and how to use these tiles.

Run Program

image36.png

Use the Run Program tile to have your workflow run an executable file. For example, use this tile to create a step in your workflow that runs a third-party automated sampling accessory.

Combine this tile with the Variable tile or other tiles to create powerful workflows. For example, use the count variable from the Repeat tile to automatically increment an argument passed to the executable.

The Run Program tile can run only executable files that do not require any user interaction and that do not have a user interface.

 

For a description of this tile’s settings and options, read Run Program on the knowledge base.

Tips for effective workflow management

  • The options in the Measure tile reflect the instrument you are currently connected to when creating a workflow. For example, if you are connected to a Nicolet Summit PRO spectrometer, the Measure tile shows settings that are available on that spectrometer. If you are in Workstation mode, it uses the instrument you were most recently connected to.

To design a workflow for an instrument that you are not connected to (for example, you are using an iS50 but designing a workflow to be run on a Summit), you can use the data simulator. Go to Configure > Connectivity and choose Simulator. Choose the instrument you are designing for and select Connect. Remember to update your connection when you are done working in the workflow Editor.

  • Keep workflows simple: Avoid unnecessary complexity to make workflows easier to manage and update.

  • Organize files: Keep a well-organized folder structure for resources used in workflows, including any imported spectra, QNT files, image resources, and other external resources.

  • Update dependencies: Regularly update any dependencies such as quant methods and embedded workflows to ensure all workflows function correctly.

By following these guidelines, you can effectively use workflows in OMNIC Paradigm software to streamline your processes and ensure consistent, high-quality results.

 