Overview of the OMNIC Paradigm software for microscopy
Run your microscope and analyze your samples using OMNIC™ Paradigm™ software, Thermo Scientific’s streamlined material analysis software. The user-friendly dashboard screen helps you view instrument status and recent work, process your spectra, conduct multi-component searching, and create new libraries. Designed with lab managers and science educators in mind, this software helps automate workflows using an intuitive drag-and-drop workflow creator. Work remotely and collaborate with colleagues around the globe when you upload OMNIC™ Paradigm™ data to the cloud using the Thermo Scientific™ OMNIC™ Anywhere application.
Interface
When working in microscopy, you will primarily work in the dashboard and the microscope tab.
Dashboard
Begin a new session, edit measurement settings, view recent measurements, reports, and sessions, and view workflows on the dashboard. The measurement settings change somewhat when the sample location is set to a microscope.

| Label | Feature | Description |
|---|---|---|
|
1 |
Command area |
This area features the main menus, toolbar, tabs, and the system status.
|
|
2 |
Dashboard tabs |
The dashboard has three sections:
|
|
3 |
Basic settings |
This area includes basic measurement settings and background settings for individual measurements. This is also where you can start a new microscope tab to begin your analysis. |
|
4 |
Mapping session settings |
These settings are specific to mapping sessions. They are used only when you begin a session. |
|
5 |
Advanced settings |
These more advanced settings control additional microscope components and less-commonly used data collection settings. |
The microscopy measurement and microscope tab
When your sample location is set to a microscope, select Start to open a new microscope tab.

| Label | Toolbar | Description |
|---|---|---|
|
1 |
Command area |
As on the dashboard, this area includes the main menus and an updated toolbar for microscopy tools. |
|
2 |
Settings pane |
The settings pane includes all the same settings available on the dashboard. You can edit your settings here or on the dashboard. |
|
3 |
Mosaic panel |
This is the main workspace when working in a microscope tab. It shows the currently collected mosaic image of your sample. If you are using a manual stage, this pane is hidden since mapping is not supported. |
|
4 |
Spectrum panel |
The spectrum pane displays your most recent measurement or the live spectrum. |
|
5 |
Camera view |
The camera view shows a live image of the sample and includes tools for adjusting the stage and camera. Tabs in the camera view include tools for adjusting the camera view and stage position. If you install the ATR attachment, this is where you will find the ATR sensor status and controls for the ATR attachment. Select the small spectrum icon to toggle the camera view and the spectrum pane. The spectrum pane shows your collected background and sample measurements. |