Laboratory Preparation Checklist

This article provides a comprehensive checklist for laboratory preparation when using Trace Elemental Analysis instruments, ensuring accurate and reliable results, reducing contamination risks, and enhancing overall laboratory efficiency. It includes essential laboratory apparatus, bottles, flasks, storage containers, autosampler vials, pipettes, cleaning supplies, and acids/reagents. Key instruments include Mettler Toledo balance, Thermo Scientific bottles, Fisherbrand beakers, and Kimwipes™ fo

Originally submitted by craig.kerneklian@thermofisher.com on 3/25/2025 2:59:54 AM UTC

Issue

This article provides a comprehensive checklist for laboratory preparation when using Trace Elemental Analysis instruments. Proper preparation ensures accurate and reliable results, reduces contamination risks, and enhances overall laboratory efficiency.

Environment

  • iCAP RQ
  • iCAP Q
  • iCAP Pro

Resolution

Follow the checklist below to ensure the laboratory is adequately prepared for using Trace Elemental Analysis instruments:

  • Laboratory Apparatus:
    • Mettler Toledo NewClassic MS Semi-Micro Balance o Purpose: Sample Prep o Model No.: 11142056 o Catalog No.: 01-911-370 o Capacity: 120 g o Package: Each o Recommended Quantity: 1
  •  Bottles, Flasks, and Storage Containers:
    • Thermo Scientific Nalgene LLDPE Tank with Cover o Purpose: Acid Bath Container o Model No.: 141000020 o Catalog No.: 14-831-330K o Capacity: 50 L o Package: Each o Recommended Quantity: 1 (Optional)
    • Thermo Scientific Nalgene Large Narrow-Mouth LDPE Bottles with Closure o Purpose: Diluent Storage; Waste Container o Model No.: 22020010 o Catalog No.: 02-923J o Capacity: 4 L o Package: Each o Recommended Quantity: 4
    • Thermo Scientific Nalgene Narrow-Mouth LDPE Bottles with Closure (1L, 500 mL, 250 mL) o Purpose: Solution Storage; Autosampler Rinse o Model No.: 20030032, 20039016, 20030008 o Catalog No.: 02-924-6F, 02-923-11G, 02-924-6D o Capacity: 1 L, 500 mL, 250 mL o Package: Pack of 6, Pack of 12, Pack of 12 o Recommended Quantity: 1 each
    • Corning Class A Reusable PMP Volumetric Flasks with Tapered PP Stopper (1 L, 100 mL, 50 mL) o Purpose: Solution and Sample Prep o Model No.: 5640P1L, 5640P100, 5640P50 o Catalog No.: 10-210-643, 10-210-640, 10-210-639 o Capacity: 1 L, 100 mL, 50 mL o Package: Case of 3, Case of 6, Case of 6 o Recommended Quantity: 1 each
    • Fisherbrand™ Polypropylene Disposable Beakers - 15 mL o Purpose: Dispensing Standards and SRMs o Model No.: FB012918 o Catalog No.: FB012918 o Capacity: 15 mL o Package: Case of 1000 o Recommended Quantity: 1
    • Fisherbrand™ Polystyrene Antistatic Weighing Dishes o Purpose: Sample Prep o Model No.: 08-732-113 o Catalog No.: 08-732-113 o Size: 3.5 in x 3.5 in o Package: Case of 500 o Recommended Quantity: 1
  • Autosampler Vials and Bottles:
    • Fisherbrand™ Easy Reader™ Conical Polypropylene Centrifuge Tubes (15 mL, 50 mL) o Purpose: Autosampler vial (90 position racks, 21 position racks) o Model No.: 05-539-12, 05-539-6 o Catalog No.: 05-539-12, 05-539-6 o Capacity: 15 mL, 50 mL o Package: Case of 500 o Recommended Quantity: 1 (Optional)
    • VWR® Metal-Free Centrifuge Tubes, Polypropylene, Sterile (15 mL, 50 mL) o Purpose: Autosampler vial (90 position racks, 21 position racks) o Model No.: 89049-170, 89049-174 o Catalog No.: 89049-170, 89049-174 o Capacity: 15 mL, 50 mL o Package: Case of 500 o Recommended Quantity: 1 each
  •  Pipettes and Pipette Tips:
    • Thermo Scientific Finnpipette F2 Adjustable-Volume Pipette o Purpose: Solution and Sample Prep o Model No.: 4642080, 4642090, 4642110 o Catalog No.: 14-386-319, 14-386-320, 14-386-322 o Capacity: 20-200 μL, 100-1000 μL, 1-10 mL o Package: Each o Recommended Quantity: 1 each
    • Thermo Scientific™ Finntip™ Pipette Specific Extended Length Pipette Tips (200 μL, 1000 μL, 10 mL) o Purpose: Solution and Sample Prep o Model No.: 9400133, 9401423, 94060970 o Catalog No.: 21-377-44, 21-377-601, 14-487-90 o Capacity: 200 μL, 1000 μL, 1 mL o Package: Case of 960, Case of 480, Pack of 100 o Recommended Quantity: 1 each (5 packs for 10 mL)
  • Cleaning Supplies:
    • Kimberly-Clark Professional™ Kimwipes™ Delicate Task Wipers, 2-ply (16.6 x 14.7 in.) o Purpose: Cleaning o Model No.: 34721 o Catalog No.: 06-666-11 o Size: 16.6 in x 14.7 in o Package: Pack of 90 o Recommended Quantity: 5
    • Kimberly-Clark Professional™ Kimwipes™ Delicate Task Wipers, 1-ply (8.4 in x 4.4 in) o Purpose: Cleaning o Model No.: 34155 o Catalog No.: 06-666A o Size: 8.4 in x 4.4 in o Package: Pack of 280 o Recommended Quantity: 5
    • Thermo Scientific Nalgene Unitary LDPE Wash Bottle (500 mL) o Purpose: Cleaning and Rinsing o Model No.: 24020500 o Catalog No.: 03-409-10E o Capacity: 500 mL o Package: Pack of 4 o Recommended Quantity: 1 .
  • Acids and Reagents:
    • Hydrochloric Acid (TraceMetal™ Grade) - 2.5 L o Purpose: Solution and Sample Prep; Labware Cleaning o Model No.: A508-P212 o Catalog No.: A508-P212 o Capacity: 2.5 L o Package: Each o Recommended Quantity: 1
    • Hydrochloric Acid (Optima™ Grade) - 500 mL o Purpose: Solution and Sample Prep o Model No.: A466-500 o Catalog No.: A466-500 o Capacity: 500 mL o Package: Each o Recommended Quantity: 1 (Optional)
    • Nitric Acid (TraceMetal™ Grade) - 2.5 L o Purpose: Solution and Sample Prep; Labware Cleaning o Model No.: A509P212 o Catalog No.: A509P212 o Capacity: 2.5 L o Package: Each o Recommended Quantity: 1
    • Nitric Acid (Optima™ Grade) - 500 mL o Purpose: Solution and Sample Prep o Model No.: A467-500 o Catalog No.: A467-500 o Capacity: 500 mL