IC Parts Test - Anthony
Thermo Fisher Scientific
Parts Explorer
Browse service parts by product model and category. All existing functionality is preserved, with a more polished layout, clearer hierarchy, and easier-to-scan part details.
Inuvion
+
Category
Full System
+
Part
22185-60100 – Inuvion Core System, CD
+
|
Part Number
22185-60100
📋
Copied
Part Description Inuvion Core System, CD SAP Part Description PROD,INUVION,CORE SYSTEM,CD Who Can Order Service Only Status Active |
Part
22185-60104 – Inuvion System, DGS, CD
+
|
Part Number
22185-60104
📋
Copied
Part Description Inuvion System, DGS, CD SAP Part Description PROD,INUVION,SYSTEM,DGS,CD Who Can Order Service Only Status Active |
Part
22185-60108 – Inuvion System with RFIC, DGS, CD
+
|
Part Number
22185-60108
📋
Copied
Part Description Inuvion System with RFIC, DGS, CD SAP Part Description PROD,INUVION,SYSTEM,+RFIC,DGS,CD Who Can Order Service Only Status Active |
Category
Option Kit
+
Part
22185-62400 – Column Oven
+
|
Part Number
22185-62400
📋
Copied
Part Description Column Oven SAP Part Description KIT,OVEN,COLUMN,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
22185-62700 – Trap Column Clip
+
Part
22185-62701 – Seal Wash
+
|
Part Number
22185-62701
📋
Copied
Part Description Seal Wash SAP Part Description KIT,SEAL WASH,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-62702 – Regenerant Pump
+
|
Part Number
22185-62702
📋
Copied
Part Description Regenerant Pump SAP Part Description PROD,KIT,REGENERATION PUMP,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-62703 – 10-Port High Pressure Valve
+
|
Part Number
22185-62703
📋
Copied
Part Description 10-Port High Pressure Valve SAP Part Description KIT,HP VALVE,AUX,10 PORT,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
22185-62704 – 6-Port High Pressure Valve
+
Part
22185-62706 – Digital Pressure Regulator
+
|
Part Number
22185-62706
📋
Copied
Part Description Digital Pressure Regulator SAP Part Description KIT,DIGITAL REGULATOR,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
22185-62707 – Liquid Level Sensor, 2L
+
|
Part Number
22185-62707
📋
Copied
Part Description Liquid Level Sensor, 2L SAP Part Description KIT,ELUENT MONITOR,2L,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
22185-62708 – Liquid Level Sensor, 4L
+
|
Part Number
22185-62708
📋
Copied
Part Description Liquid Level Sensor, 4L SAP Part Description KIT,ELUENT MONITOR,4L,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
60-075318 – Manual Pressure Regulator
+
|
Part Number
60-075318
📋
Copied
Part Description Manual Pressure Regulator SAP Part Description ASSY,EO GAS RGLTR,ICS4,CAP Who Can Order Customer and Service Status Active |
Part
B51000232 – Viper Tubing Kit
+
Category
Upgrade Kit
+
Part
22185-62001 – Upgrade Kit: Core to Inuvion
+
|
Part Number
22185-62001
📋
Copied
Part Description Upgrade Kit: Core to Inuvion SAP Part Description KIT,UPGRADE,CORE TO INUVION Who Can Order Service Only Status Active |
Part
22185-62002 – Upgrade Kit: Inuvion to RFIC
+
|
Part Number
22185-62002
📋
Copied
Part Description Upgrade Kit: Inuvion to RFIC SAP Part Description KIT,UPGRADE,INUVION TO INUVION RFIC Who Can Order Service Only Status Active Service Manual |
Category
System
+
Part
B51001031 – Main DC power cable assembly
+
|
Part Number
B51001031
📋
Copied
Part Description Main DC power cable assembly SAP Part Description ASSY,CBL,DC PWR,MEZ-MAIN, INUVION Who Can Order Service Status Active |
Part
00006-03-00013 – Power Fuses
+
|
Part Number
00006-03-00013
📋
Copied
Part Description Power Fuses SAP Part Description FUSE,8A,250V,5X20MM,TL,RoHS,UL VDE Who Can Order Service Only Status Active Service Manual |
Part
00202-99-00137 – Power entry model
+
|
Part Number
00202-99-00137
📋
Copied
Part Description Power entry model SAP Part Description POWER ENTRY MODULE/FLTR,250Vac,10A,RoHS Who Can Order Service Status Active |
Part
00202-99-00138 – Fuse Holder
+
|
Part Number
00202-99-00138
📋
Copied
Part Description Fuse Holder SAP Part Description FUSEDRAWER,5X20mm,2POLE,RoHS Who Can Order Service Only Status Active Service Manual |
Part
22153-40025 – Column holder clip
+
|
Part Number
22153-40025
📋
Copied
Part Description Column holder clip SAP Part Description CLIP, 3/8OD COL HOLDER, ITGN Who Can Order Customer and Service Status Active |
Part
22183-61205R – EPS board
+
Part
22185-40001 – Tubing routing clip
+
|
Part Number
22185-40001
📋
Copied
Part Description Tubing routing clip SAP Part Description CLIP,TUBING,ROUTING,MOLDED,INUVION Who Can Order Service Status Active |
Part
22185-60201 – Optical Leak Detector
+
|
Part Number
22185-60201
📋
Copied
Part Description Optical Leak Detector SAP Part Description ASSY,DET,OPT LEAK, INUVION Who Can Order Service Only Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-61001R – Front LED Display PCB
+
|
Part Number
22185-61001R
📋
Copied
Part Description Front LED Display PCB SAP Part Description ASSY,PCB,LED,INUVION Who Can Order Service Only Status Active Service Manual |
Part
22185-61002R – Main CPU Board
+
|
Part Number
22185-61002R
📋
Copied
Part Description Main CPU Board SAP Part Description ASSY,PCB,CPU,INUVION Who Can Order Service Only Status Active Service Manual Relevant Factory Communications Notes New revision of mainboard "F" will be in production in late September 2025. Please order the revision F mainboard via the regional L2 support team and the local service buyer. |
Part
22185-61003R – Mezzanine PCB
+
|
Part Number
22185-61003R
📋
Copied
Part Description Mezzanine PCB SAP Part Description ASSY,PCB,MEZZANINE,INUVION Who Can Order Service Only Status Active Service Manual |
Part
22185-61011R – CD patch board assembly
+
|
Part Number
22185-61011R
📋
Copied
Part Description CD patch board assembly SAP Part Description ASSY,PCB,CD,PATCH,INUVION Who Can Order Service Status Active |
Part
22185-62000 – Shipping packaging kit
+
|
Part Number
22185-62000
📋
Copied
Part Description Shipping packaging kit SAP Part Description KIT,PACKAGING,SHIPPING,INUVION Who Can Order Service Status Active |
Part
22185-62200 – Low pressure vacuum degas kit (with cartridge)
+
|
Part Number
22185-62200
📋
Copied
Part Description Low pressure vacuum degas kit (with cartridge) SAP Part Description KIT,DEGAS,LP VACUUM,W/CRTRG,INVN Who Can Order Service Status Active |
Part
22185-63003 – Eluent valve seal wash leak sensor assembly
+
|
Part Number
22185-63003
📋
Copied
Part Description Eluent valve seal wash leak sensor assembly SAP Part Description ASSY,CBL,ELUVLV,SL WSH,LK SNSR,INUVION Who Can Order Service Status Active |
Part
22185-63004 – LED display cable assembly
+
|
Part Number
22185-63004
📋
Copied
Part Description LED display cable assembly SAP Part Description ASSY,CBL,LED,DISPLAY,INUVION Who Can Order Service Status Active |
Part
22185-63005 – Column heater cable assembly
+
|
Part Number
22185-63005
📋
Copied
Part Description Column heater cable assembly SAP Part Description ASSY,CBL,COLUMN-HTR,INUVION Who Can Order Service Status Active |
Part
22185-63006 – Injection valve cable assembly
+
|
Part Number
22185-63006
📋
Copied
Part Description Injection valve cable assembly SAP Part Description ASSY,CBL,VLV,INJ,INUVION Who Can Order Service Status Active |
Part
22185-63007 – RFIC stand cable assembly
+
|
Part Number
22185-63007
📋
Copied
Part Description RFIC stand cable assembly SAP Part Description ASSY,CBL,RFIC STAND,INUVION Who Can Order Service Status Active |
Part
22185-63008 – Degas pump cable assembly
+
|
Part Number
22185-63008
📋
Copied
Part Description Degas pump cable assembly SAP Part Description ASSY,CBL,PUMP,DEGAS,IDEX,INUVION Who Can Order Service Status Active |
Part
22185-63011 – CD detector patch cable assembly
+
|
Part Number
22185-63011
📋
Copied
Part Description CD detector patch cable assembly SAP Part Description ASSY,CBL,DET,CD PATCH,INUVION Who Can Order Service Status Active |
Part
22185-63013 – Suppressor cable assembly
+
|
Part Number
22185-63013
📋
Copied
Part Description Suppressor cable assembly SAP Part Description ASSY,CBL,BLKHD,SUPPR, INUVION Who Can Order Service Status Active |
Part
22185-63014 – System Exhaust Rear Fan
+
|
Part Number
22185-63014
📋
Copied
Part Description System Exhaust Rear Fan SAP Part Description ASSY,CBL,FAN,ENTRY, INUVION Who Can Order Service Only Status Active Service Manual |
Part
22185-63015 – Pump patch cable assembly
+
|
Part Number
22185-63015
📋
Copied
Part Description Pump patch cable assembly SAP Part Description ASSY,CBL,PATCH,PUMP,INUVION Who Can Order Service Status Active |
Part
22185-63017 – RFIC drain cable assembly
+
|
Part Number
22185-63017
📋
Copied
Part Description RFIC drain cable assembly SAP Part Description ASSY,CBL,GND DRAIN,RFIC STAND,INUVION Who Can Order Service Status Active |
Part
22185-63018 – Seal wash cable assembly
+
|
Part Number
22185-63018
📋
Copied
Part Description Seal wash cable assembly SAP Part Description ASSY,CBL,SEAL WASH,INUVION Who Can Order Service Status Active |
Part
22185-63020 – Auxilliary valve cable assembly
+
|
Part Number
22185-63020
📋
Copied
Part Description Auxilliary valve cable assembly SAP Part Description
ASSY, CBL, VLV, AUX,INUVION Who Can Order Service Status Active |
Part
22185-63022 – Gas regulator cable assembly
+
|
Part Number
22185-63022
📋
Copied
Part Description Gas regulator cable assembly SAP Part Description ASSY, CBL, GAS REGULATOR, MEZZ,INUVION Who Can Order Service Status Active |
Part
22185-63028 – Peristaltic pump REGEN cable assembly
+
|
Part Number
22185-63028
📋
Copied
Part Description Peristaltic pump REGEN cable assembly SAP Part Description ASSY,CBL,PERI PUMP REGEN TO MEZZ,INUVION Who Can Order Service Status Active |
Part
22185-63030 – Blu ring LED cable assembly
+
|
Part Number
22185-63030
📋
Copied
Part Description Blu ring LED cable assembly SAP Part Description
ASSY,CBL,SPST, BLU RING LED, INUVION Who Can Order Service Status Active |
Part
B51000344 – Pressure transducer cable assembly
+
|
Part Number
B51000344
📋
Copied
Part Description Pressure transducer cable assembly SAP Part Description
ASSY,CBL,PRESS XDUCER,INUVION Who Can Order Service Status Active |
Part
B51000682 – Door Assembly
+
|
Part Number
B51000682
📋
Copied
Part Description Door Assembly SAP Part Description KIT,PREMIUM DOOR UPGRADE,INUVION Who Can Order Service Only Status Active Service Manual |
Part
B51000716 – DC Filter PCB
+
|
Part Number
B51000716
📋
Copied
Part Description DC Filter PCB SAP Part Description ASSY,PCB,DC,FILTER,INUVION Who Can Order Service Only Status Active Service Manual |
Part
B51000719 – AC Surge PCB
+
|
Part Number
B51000719
📋
Copied
Part Description AC Surge PCB SAP Part Description ASSY,PCB,AC,FILTER,INUVION Who Can Order Service Only Status Active Service Manual |
Part
B51001027 – AC surge-in power cable assembly
+
|
Part Number
B51001027
📋
Copied
Part Description AC surge-in power cable assembly SAP Part Description ASSY,CBL,PWR,AC SURGE-IN,INUVION Who Can Order Service Status Active |
Part
B51001028 – AC surge-out power cable assembly
+
|
Part Number
B51001028
📋
Copied
Part Description AC surge-out power cable assembly SAP Part Description ASSY,CBL,PWR,AC SURGE-OUT, INUVION Who Can Order Service Status Active |
Part
B51001029 – Main board DC power cable assembly
+
|
Part Number
B51001029
📋
Copied
Part Description Main board DC power cable assembly SAP Part Description ASSY,CBL,DC PWR,MAIN BRD, INUVION Who Can Order Service Status Active |
Part
B51001030 – CD DC power cable assembly
+
|
Part Number
B51001030
📋
Copied
Part Description CD DC power cable assembly SAP Part Description
ASSY,CBL,DC PWR, MEZ-CD, INUVION Who Can Order Service Status Active |
Part
B51001032 – System DC power cable assembly
+
|
Part Number
B51001032
📋
Copied
Part Description System DC power cable assembly SAP Part Description ASSY,CBL,DC PWR,SYSTEM, INUVION Who Can Order Service Status Active |
Part
B51001360 – Power supply cable
+
|
Part Number
B51001360
📋
Copied
Part Description Power supply cable SAP Part Description
ASSY,CBL,PWR SUPPLY,GND, INUVION Who Can Order Service Status Active |
Part
B51001471 – Suppressor Cable
+
|
Part Number
B51001471
📋
Copied
Part Description Suppressor Cable SAP Part Description KIT,SUPPRESSOR DOOR,INUVION Who Can Order Service Only Status Active Service Manual |
Part
B51001768 – Shipping containter (box and foam)
+
|
Part Number
B51001768
📋
Copied
Part Description Shipping containter (box and foam) SAP Part Description CONTAINER,BOX AND FOAM,SHIP,INUVION Who Can Order Service Status Active |
Part
B51002428 – Column Heater Heat
Exchanger, 1/16" OD tubing _x000D_
+
|
Part Number
B51002428
📋
Copied
Part Description Column Heater Heat
Exchanger, 1/16" OD tubing _x000D_ SAP Part Description ASSY,COL HTR,HEAT EXCHANGER,.007"
ID TBG Who Can Order Customer and Service Status Active |
Part
B51002429 – Column Heater Heat
Exchanger, 1/32" OD tubing
+
|
Part Number
B51002429
📋
Copied
Part Description Column Heater Heat
Exchanger, 1/32" OD tubing SAP Part Description KIT,CH,HEAT XCHGR,INUVION Who Can Order Customer and Service Status Active |
Part
C0012-01-00085 – Power Supply
+
|
Part Number
C0012-01-00085
📋
Copied
Part Description Power Supply SAP Part Description PWR SPY,85-264VAC,350W,24V,8.3A,RoHS Who Can Order Service Only Status Active Service Manual |
Part
C0201-99-00740 – 180 degree invisible hinges (black)
+
|
Part Number
C0201-99-00740
📋
Copied
Part Description 180 degree invisible hinges (black) SAP Part Description HINGES,INVISIBLE,180DEG,BLACK,RoHS Who Can Order Service Status Active |
Category
Pump
+
Part
045994 – Check Valve Cartridge SB
+
|
Part Number
045994
📋
Copied
Part Description Check Valve Cartridge SB SAP Part Description ASSY,CRTG,2-SB BALL,GP40 Who Can Order Customer and Service Status Active Service Manual |
Part
048722 – Piston rinse seal
+
|
Part Number
048722
📋
Copied
Part Description Piston rinse seal SAP Part Description SEAL,PISTON RINSE,SB, RoHS Who Can Order Customer and Service Status Active |
Part
055752 – O-ring for waste valve or priming valve
+
|
Part Number
055752
📋
Copied
Part Description O-ring for waste valve or priming valve SAP Part Description
O-RING,-008,0.176X .070,WHT PRF Who Can Order Customer and Service Status Active |
Part
22185-20206 – Check Valve Outlet Holder (No Cartridge)
+
|
Part Number
22185-20206
📋
Copied
Part Description Check Valve Outlet Holder (No Cartridge) SAP Part Description HOLDER,CK VLV,OT,PUMP,PEEK,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual Notes This part is the holder only, it does not include the cartridge (045994) |
Part
22185-20207 – Check Valve Inlet Holder (No Cartridge)
+
|
Part Number
22185-20207
📋
Copied
Part Description Check Valve Inlet Holder (No Cartridge) SAP Part Description HOLDER,CK VLV,IN,PUMP,PEEK,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual Notes This part is the holder only, it does not include the cartridge (045994) |
Part
22185-20210 – Pump Head Seal Install Tool
+
|
Part Number
22185-20210
📋
Copied
Part Description Pump Head Seal Install Tool SAP Part Description TOOL,PUMP HEAD,SEAL INSTALL,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-60147 – Pump Pulse Damper
+
|
Part Number
22185-60147
📋
Copied
Part Description Pump Pulse Damper SAP Part Description ASSY,DAMPER,PRESSURE RIPPLE,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-61008R – Pump Patch Board
+
|
Part Number
22185-61008R
📋
Copied
Part Description Pump Patch Board SAP Part Description ASSY,PCB,PUMP,PATCH,INUVION Who Can Order Service Only Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-63027 – Shutoff Valve
+
|
Part Number
22185-63027
📋
Copied
Part Description Shutoff Valve SAP Part Description ASSY,CBL,VLV,SHUTOFF, INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-98201 – Seal Wash Seal
+
|
Part Number
22185-98201
📋
Copied
Part Description Seal Wash Seal SAP Part Description SEAL,PISTON,1/8",PUMP,REAR,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
22185-98202 – Piston, 1/8", Pump, Inuvion
+
|
Part Number
22185-98202
📋
Copied
Part Description Piston, 1/8", Pump, Inuvion SAP Part Description PISTON,1/8",PUMP,INUVION Who Can Order Customer and Service Status Active Service Manual |
Part
B51000563 – Piston Seal
+
|
Part Number
B51000563
📋
Copied
Part Description Piston Seal SAP Part Description SEAL,ENERGIZER,FLANGLESS,1/8ID,GOLD Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51001284 – Regen Pump Tubing (Pharmed)
+
|
Part Number
B51001284
📋
Copied
Part Description Regen Pump Tubing (Pharmed) SAP Part Description ASSY,TUBE,REGEN PUMP,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Relevant Factory Communications |
Part
B51002323 – Pump Motor Assembly
+
|
Part Number
B51002323
📋
Copied
Part Description Pump Motor Assembly SAP Part Description KIT,PUMP,COMPLETE,INUVION Who Can Order Service Only Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51002398 – Pump Head
+
|
Part Number
B51002398
📋
Copied
Part Description Pump Head SAP Part Description KIT,PUMP HEAD,FLANGLESS,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51002664 – Pressure Transducer
+
|
Part Number
B51002664
📋
Copied
Part Description Pressure Transducer SAP Part Description KIT,TRANSDUCER,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51002818 – O-Ring 1.264IDX0.063THK
+
|
Part Number
B51002818
📋
Copied
Part Description O-Ring 1.264IDX0.063THK SAP Part Description O-RING,1.264IDX0.063THK,FKM,RoHS Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51002819 – O-Ring 0.433IDX0.063THK
+
|
Part Number
B51002819
📋
Copied
Part Description O-Ring 0.433IDX0.063THK SAP Part Description O-RING,0.433IDX0.063THK,FKM,RoHS Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51004740 – Pump Waste Tubing Kit
+
|
Part Number
B51004740
📋
Copied
Part Description Pump Waste Tubing Kit SAP Part Description KIT,TUBING,WASTE,PUMP,INUVION Who Can Order Customer and Service Status Active Service Manual Relevant Factory Communications |
Category
Injection
+
Part
030391 – Sample Loop, 100 µL
+
Part
042857 – Sample Loop, 25 µL
+
Part
042949 – Sample Loop, 10 µL
+
Part
075917 – Injection Valve, 6-Port
+
|
Part Number
075917
📋
Copied
Part Description Injection Valve, 6-Port SAP Part Description VALVE,6PORT,PK,RHEO,TITAN,6K,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
075971 – Valve Pod for 6-Port
+
|
Part Number
075971
📋
Copied
Part Description Valve Pod for 6-Port SAP Part Description VLV POD ASSY,6 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual |
Part
075972 – Valve Pod for 10-Port
+
|
Part Number
075972
📋
Copied
Part Description Valve Pod for 10-Port SAP Part Description VLV POD ASSY,10 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual Relevant Knowledge Articles |
Part
075973 – 6-Port Valve Rebuild Kit
+
Part
079054 – High-Pressure Valve
Rebuild Kit, 10-Port
+
|
Part Number
079054
📋
Copied
Part Description High-Pressure Valve
Rebuild Kit, 10-Port SAP Part Description KIT,REBUILD,VLV,10-PORT,6K Who Can Order Customer and Service Status Active |
Category
Detection
+
Part
B51002403 – Conductivity Detector Cell
+
|
Part Number
B51002403
📋
Copied
Part Description Conductivity Detector Cell SAP Part Description KIT,CD CELL,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Category
Eluent
+
Part
045987 – End-Line Filter
+
|
Part Number
045987
📋
Copied
Part Description End-Line Filter SAP Part Description FLTR,END-LINE,ELU,1/4-28 UHMW PE Who Can Order Customer and Service Status Active |
Part
062510 – Eluent Reservoir, 2L
+
Part
063292 – Eluent Reservoir, 4L
+
Part
074505 – High-Pressure Inline Filter
+
Part
075778 – EGC 500 KOH
+
|
Part Number
075778
📋
Copied
Part Description EGC 500 KOH SAP Part Description Dionex EGC 500 KOH Cartridge Who Can Order Customer and Service Status Active |
Part
075779 – EGC 500 MSA
+
|
Part Number
075779
📋
Copied
Part Description EGC 500 MSA SAP Part Description Dionex EGC 500 MSA Cartridge Who Can Order Customer and Service Status Active |
Part
078520 – Regulator Kit
+
|
Part Number
078520
📋
Copied
Part Description Regulator Kit SAP Part Description PROD,REGULATOR,GAS,ICS4 Who Can Order Customer and Service Status Active |
Part
088453 – EGC 500 K2CO3
+
|
Part Number
088453
📋
Copied
Part Description EGC 500 K2CO3 SAP Part Description Dionex EGC 500 K2CO3 Cartridge Who Can Order Customer and Service Status Active |
Part
088467 – Carbonate Mixer, 2mm
+
Part
088468 – Carbonate Mixer, 4mm
+
|
Part Number
088468
📋
Copied
Part Description Carbonate Mixer, 4mm SAP Part Description PROD,MIXER,EGC500,K2CO3,4MM,HP Who Can Order Customer and Service Status Active |
Part
088471 – Dionex EPM 500 Electrolytic pH Modifier
+
Part
088662 – Dionex CR-ATC 600
+
Part
088663 – Dionex CR-CTC 600
+
|
Part Number
088663
📋
Copied
Part Description Dionex CR-CTC 600 SAP Part Description PROD,COL,CR-CTC600,TRACKING ENABLED Who Can Order Customer and Service Status Active |
Part
106-60001 – RFIC Degasser
+
Part
C0108-01-00085 – Degas Vacuum Pump
+
|
Part Number
C0108-01-00085
📋
Copied
Part Description Degas Vacuum Pump SAP Part Description PUMP,VACUUM,LP,IDEX,9000-1920,15V-24V Who Can Order Service Only Status Active Service Manual |
Part
C0950-01-01206 – Eluent Vacuum Degas Chamber
+
|
Part Number
C0950-01-01206
📋
Copied
Part Description Eluent Vacuum Degas Chamber SAP Part Description DEGASSER,IDEX H&S,9000-2071,RoHS Who Can Order Service Only Status Active Service Manual |
Category
Accessory
+
Category
PM Parts
+
Part
045987 – End-Line Filter
+
Part
045994 – Check Valve Cartridge SB
+
|
Part Number
045994
📋
Copied
Part Description Check Valve Cartridge SB SAP Part Description ASSY,CRTG,2-SB BALL,GP40 Who Can Order Customer and Service Status Active Service Manual Notes Quantity 2 for PM |
Part
062823 – Next Due Date Label
+
|
Part Number
062823
📋
Copied
Part Description Next Due Date Label SAP Part Description LABEL,PM KIT,NEXT DUE DATE Who Can Order Customer and Service Status Active |
Part
075973 – 6-Port Valve Rebuild Kit
+
|
Part Number
075973
📋
Copied
Part Description 6-Port Valve Rebuild Kit SAP Part Description KIT,REBUILD, VLV, 6-PORT,6K Who Can Order Customer and Service Status Active |
Part
22185-98201 – Seal Wash Seal
+
|
Part Number
22185-98201
📋
Copied
Part Description Seal Wash Seal SAP Part Description SEAL,PISTON,1/8",PUMP,REAR,INUVION Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual Notes Quantity 2 for PM |
Part
B51000563 – Piston Seal
+
|
Part Number
B51000563
📋
Copied
Part Description Piston Seal SAP Part Description SEAL,ENERGIZER,FLANGLESS,1/8ID,GOLD Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual Notes Quantity 2 for PM |
Part
B51001547 – Inuvion PM Kit
+
|
Part Number
B51001547
📋
Copied
Part Description Inuvion PM Kit SAP Part Description ASSY,KIT,PM,INUVION Who Can Order Customer and Service Status Active Relevant Knowledge Articles |
Part
B51002818 – O-Ring 1.264IDX0.063THK
+
|
Part Number
B51002818
📋
Copied
Part Description O-Ring 1.264IDX0.063THK SAP Part Description O-RING,1.264IDX0.063THK,FKM,RoHS Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Part
B51002819 – O-Ring 0.433IDX0.063THK
+
|
Part Number
B51002819
📋
Copied
Part Description O-Ring 0.433IDX0.063THK SAP Part Description O-RING,0.433IDX0.063THK,FKM,RoHS Who Can Order Customer and Service Status Active Calibration Needed Calibration May Be Required Service Manual |
Category
Spares
+
Part
042772 – 10-32 fitting plug
+
|
Part Number
042772
📋
Copied
Part Description 10-32 fitting plug SAP Part Description FTG,PLUG,10-32 BLK,P1 Who Can Order Customer and Service Status Active Service Manual |
Category
Tools
+
Part
046175 – High-Pressure Calibration Gauge
+
|
Part Number
046175
📋
Copied
Part Description High-Pressure Calibration Gauge SAP Part Description ASSY,GAUGE,5000 PSI,ELECTR,SVC Who Can Order Service Only Status Active Service Manual |
Part
062336 – 1/2-in Wrench
+
|
Part Number
062336
📋
Copied
Part Description 1/2-in Wrench SAP Part Description TOOL,WRENCH,1/2in,OPEN/BOX END Who Can Order Customer and Service Status Active Service Manual |
Category
Misc Part
+
Part
22185-40701 – CRD Cradle
+
|
Part Number
22185-40701
📋
Copied
Part Description CRD Cradle SAP Part Description CRADLE,CRD,MOLDED,INVN Who Can Order Customer and Service Status Active |
Part
960777 – USB Cable (6ft; 1.8m)
+
|
Part Number
960777
📋
Copied
Part Description USB Cable (6ft; 1.8m) SAP Part Description CBL,USB A/M TO B/M,6FT,RoHS Who Can Order Customer and Service Status Active |
Part
B51001953 – Digital Regulator Display
+
|
Part Number
B51001953
📋
Copied
Part Description Digital Regulator Display SAP Part Description KIT,DISPLAY,DIGITAL REGULATOR,INUVION Who Can Order Customer and Service Status Active |
Part
B51001954 – Digital Regulator, Regulator
Only
+
|
Part Number
B51001954
📋
Copied
Part Description Digital Regulator, Regulator
Only SAP Part Description
KIT,REGULATOR,DIGITAL REGULATOR,INUVION Who Can Order Customer and Service Status Active |
Tools
+
Fittings
+
Category
Bolt
+
Part
052230 – ¼-28 for flat fitting, 1/16 in. tubing
+
Part
052267 – ¼-28 for 1/8 in. tubing Natural PEEKTM
+
Part
057934 – ¼-28 for 1/8 in. tubing Natural PEEKTM, short length
+
Part
071358 – ¼-28 for flat fitting, 1/16 in. tubing
+
Part
074449 – Blue double cone ferrule bolt, 10- 32
+
Part
22000-98001 – High-pressure connections to 1/16 in. tubing (columns, suppressors, etc.).
+
|
Part Number
22000-98001
📋
Copied
Part Description High-pressure connections to 1/16 in. tubing (columns, suppressors, etc.). SAP Part Description FTG,BOLT,10-32,1/4 HEX,PEEK,NAT,RoHS Who Can Order Customer and Service Status Active Notes High-pressure connections to 1/16 in. tubing (columns, suppressors, etc.). |
Category
Ferrule
+
Part
043225 – Pack of 10 Tan double-cone ferrules
+
Part
043276 – Tan double-cone ferrule
+
Part
048949 – 1/8 in. (yellow, reverse type)
+
Part
052231 – Flat type reverse, 1/16 in. (for bolt above)
+
Part
062511 – Two-piece, clear cone and tan flat
+
Category
Plug
+
Part
037628 – ¼-28 Black Plug
+
Part
042772 – 10-32 Black Plug
+
Category
Syringe Adaptor
+
Part
024305 – Female Luer to male thread ¼-28
+
Category
Union
+
Part
039056 – ¼-28 to ¼-28, 0,06 in. through hole (female threaded for male connector)
+
Part
042627 – 10-32 to 10-32 (female threaded for male connector)
+
Tubing
+
Category
IC Viper Tubing
+
Part
B51000230 – Viper assembly, 0.18 mm
(0.007 in) ID, 140 mm (5.5
in)_x000D_
+
|
Part Number
B51000230
📋
Copied
Part Description Viper assembly, 0.18 mm
(0.007 in) ID, 140 mm (5.5
in)_x000D_ SAP Part Description PROD,VIPER ASSY,.007 ID,5.5 IN[140MM] Who Can Order Customer and Service Status Active |
Part
B51000233 – Viper assembly, 0.18 mm
(0.007 in) ID, 76 mm (3 in)_x000D_
+
|
Part Number
B51000233
📋
Copied
Part Description Viper assembly, 0.18 mm
(0.007 in) ID, 76 mm (3 in)_x000D_ SAP Part Description PROD,VIPER ASSY,.007 ID,3.0"[76MM] Who Can Order Customer and Service Status Active |
Part
B51000237 – Viper assembly, 0.18 mm
(0.007 in) ID, 203 mm (8 in)_x000D_
+
|
Part Number
B51000237
📋
Copied
Part Description Viper assembly, 0.18 mm
(0.007 in) ID, 203 mm (8 in)_x000D_ SAP Part Description PROD,VIPER ASSY,.007 ID,8.0"[203MM] Who Can Order Customer and Service Status Active |
Category
PEEK Tubing
+
Part
052300 – 20 ft (0.003 in. i.d.)
+
Part
052302 – 20 ft (0.013 in. i.d.)
+
Part
052304 – 20 ft (0.030 in. i.d.)
+
Part
052307 – 20 ft (0.010 in. i.d.)
+
Part
052308 – 20 ft (0.020 in. i.d.)
+
Part
052311 – 20 ft (0.005 in. i.d.)
+
Syringe
+
Category
Syringe
+
Part
016388 – 1-mL syringe
+
Standards
+
Category
Anion Standard
+
Category
Cation Standard
+
AS-AP
+
Category
System
+
Part
058053 – Leak Sensor
+
|
Part Number
058053
📋
Copied
Part Description Leak Sensor SAP Part Description ASSY,LK DET,OPT Who Can Order Status Service Manual |
Part
069820 – AS-AP DVC Assembly PCB
+
|
Part Number
069820
📋
Copied
Part Description AS-AP DVC Assembly PCB SAP Part Description PCB ASSY,DVC,AS-AP,NPB Who Can Order Status |
Part
069907 – Syringe Plunger Mounting Bolt
+
|
Part Number
069907
📋
Copied
Part Description Syringe Plunger Mounting Bolt SAP Part Description BOLT,SYRINGE MNT,AS-AP Who Can Order Status Service Manual |
Part
070208 – 10-port valve with cables (no mounting bracket)
+
|
Part Number
070208
📋
Copied
Part Description 10-port valve with cables (no mounting bracket) SAP Part Description PROD,VLV,RHEO,2/10,TITAN-HP,PK Who Can Order Status Service Manual |
Part
070209 – 6-port valve with cables (no mounting bracket)
+
|
Part Number
070209
📋
Copied
Part Description 6-port valve with cables (no mounting bracket) SAP Part Description PROD,VLV,RHEO,2/6,TITAN-HP,PK Who Can Order Status Service Manual |
Part
074360 – Syringe Drive Assembly
+
|
Part Number
074360
📋
Copied
Part Description Syringe Drive Assembly SAP Part Description ASSY, SYRINGE PMP, AS-AP Who Can Order Status Service Manual |
Part
074362 – XZ Drive Assembly
+
|
Part Number
074362
📋
Copied
Part Description XZ Drive Assembly SAP Part Description ASSY, XZ DRVE,AS-AP Who Can Order Status Service Manual |
Part
074363 – TE Assembly
+
|
Part Number
074363
📋
Copied
Part Description TE Assembly SAP Part Description ASSY,TE,AS-AP Who Can Order Status Service Manual |
Part
074683 – Drain Pump Motor
+
|
Part Number
074683
📋
Copied
Part Description Drain Pump Motor SAP Part Description PUMP ASSY,PERISTALTIC,AS-AP Who Can Order Status Service Manual |
Part
074685 – Condensation Fan
+
|
Part Number
074685
📋
Copied
Part Description Condensation Fan SAP Part Description FAN ASSY,CONDENSATION,AS-AP Who Can Order Status Service Manual |
Part
074686 – Heat Exchanger Fan
+
|
Part Number
074686
📋
Copied
Part Description Heat Exchanger Fan SAP Part Description FAN ASSY,HEAT EXCHANGER,AS-AP Who Can Order Status Service Manual |
Part
074936 – Tray for 0.3mL or 1.5mL vials, 40-vial capacity
Tray for micro well plates, 96-well capacity
+
|
Part Number
074936
📋
Copied
Part Description Tray for 0.3mL or 1.5mL vials, 40-vial capacity
Tray for micro well plates, 96-well capacity SAP Part Description PROD,ASSY,RACK,40 VIAL,AS-AP Who Can Order Status Service Manual |
Part
074938 – Tray for 10mL vials, 19-vial capacity
+
|
Part Number
074938
📋
Copied
Part Description Tray for 10mL vials, 19-vial capacity SAP Part Description PROD,ASSY,RACK,19 VIAL,AS-AP Who Can Order Status Service Manual |
Part
074939 – Tray for deep well plates, 96-well capacity
+
|
Part Number
074939
📋
Copied
Part Description Tray for deep well plates, 96-well capacity SAP Part Description RACK,DEEP WELL PLATE,AS-AP Who Can Order Status Service Manual |
Part
074976 – J-clip bracket (for needle alignment)
+
|
Part Number
074976
📋
Copied
Part Description J-clip bracket (for needle alignment) SAP Part Description BRKT, J-CLIP, AS-AP Who Can Order Status Service Manual |
Part
074989 – Buffer line, 500μL
+
|
Part Number
074989
📋
Copied
Part Description Buffer line, 500μL SAP Part Description TUBING, 1200uL BUFFER LOOP, AS-AP Who Can Order Status Service Manual Notes Syringe valve to needle |
Part
074990 – Sample Transfer Line
+
|
Part Number
074990
📋
Copied
Part Description Sample Transfer Line SAP Part Description TUBING, TRANSFER LINE, AS-AP Who Can Order Status Service Manual |
Part
074998 – Buffer Loop (1200 uL)
+
|
Part Number
074998
📋
Copied
Part Description Buffer Loop (1200 uL) SAP Part Description ASSY,BUFFER LOOP,1200 uL,AS-AP Who Can Order Status Service Manual |
Part
074999 – Needle and fitting assembly
+
|
Part Number
074999
📋
Copied
Part Description Needle and fitting assembly SAP Part Description ASSY, NEEDLE AND FGT, AS-AP Who Can Order Status |
Part
075001 – AUX motor controller PSB
+
|
Part Number
075001
📋
Copied
Part Description AUX motor controller PSB SAP Part Description KIT,PCB,MTR CNTRL/AUX,AS-AP Who Can Order Status Service Manual |
Part
075002 – AS-AP Front Door with Badge
+
|
Part Number
075002
📋
Copied
Part Description AS-AP Front Door with Badge SAP Part Description KIT, FRONT DOOR W BADGE, AS-AP Who Can Order Status Service Manual |
Part
075003 – AS-AP Front Panel
+
|
Part Number
075003
📋
Copied
Part Description AS-AP Front Panel SAP Part Description KIT, FRONT PANEL, AS-AP Who Can Order Status Service Manual |
Part
075004 – Heat Exchanger Assembly
+
|
Part Number
075004
📋
Copied
Part Description Heat Exchanger Assembly SAP Part Description ASSY,HEAT EXCHANGER,AS-AP Who Can Order Status |
Part
075005 – TE Pump Assembly
+
|
Part Number
075005
📋
Copied
Part Description TE Pump Assembly SAP Part Description ASSY,TE PUMP,AS-AP Who Can Order Status |
Part
075013 – Peristaltic Pump Cartridge
+
|
Part Number
075013
📋
Copied
Part Description Peristaltic Pump Cartridge SAP Part Description CARTRIDGE, PERI PUMP, AS-AP Who Can Order Status Service Manual |
Part
075496 – Diverter Valve Cable (J8)
+
|
Part Number
075496
📋
Copied
Part Description Diverter Valve Cable (J8) SAP Part Description CBL ASSY,DVC J8,AS-AP Who Can Order Status Service Manual |
Part
075497 – Diverter Valve Cable (J6)
+
|
Part Number
075497
📋
Copied
Part Description Diverter Valve Cable (J6) SAP Part Description CBL ASSY,DVC J6,AS-AP Who Can Order Status Service Manual |
Part
075520 – Buffer line, tubing assembly, 8500μL
+
|
Part Number
075520
📋
Copied
Part Description Buffer line, tubing assembly, 8500μL SAP Part Description PROD,ASSY,TBG,LOOP, 8.5ML AS-AP Who Can Order Status Service Manual Notes Syringe valve to needle |
Part
075613 – Syringe Pump/Drive Motor
+
|
Part Number
075613
📋
Copied
Part Description Syringe Pump/Drive Motor SAP Part Description ASSY,MTR/PLY,PUMP,AS-AP Who Can Order Status Service Manual |
Part
22150-61001R – Needle Drive (Z Drive)
+
|
Part Number
22150-61001R
📋
Copied
Part Description Needle Drive (Z Drive) SAP Part Description PCB ASSY,MTR CNTLR,AS-AP,NPB Who Can Order Status Service Manual Notes The needle drive (Z drive) is also referred to as the motor controller PCB. |
Part
940063 – Power Supply
+
|
Part Number
940063
📋
Copied
Part Description Power Supply SAP Part Description PWR SPY,320W,+24V,UNIV IN Who Can Order Status Service Manual |
Part
954763 – Fuse, 4 A IEC 60127-2 fast-blow
+
|
Part Number
954763
📋
Copied
Part Description Fuse, 4 A IEC 60127-2 fast-blow SAP Part Description FUSE,04.000 AMP FAST IEC127 T1 Who Can Order Status Service Manual |
Part
AAA-069800 – Main Board PCB
+
|
Part Number
AAA-069800
📋
Copied
Part Description Main Board PCB SAP Part Description PCB ASSY,CPU,AS-AP,NPB Who Can Order Status Service Manual |
Part
AAA-069806 – Front Control Panel Assembly
+
|
Part Number
AAA-069806
📋
Copied
Part Description Front Control Panel Assembly SAP Part Description PCB ASSY,FRNT PNL,AS-AP,NPB Who Can Order Status Service Manual |
Category
Injection
+
Part
069872 – Injection Port
+
|
Part Number
069872
📋
Copied
Part Description Injection Port SAP Part Description SEAL,NEEDLE,AS-AP Who Can Order Status Service Manual |
Part
069914 – Sampling needle
+
|
Part Number
069914
📋
Copied
Part Description Sampling needle SAP Part Description NEEDLE,PEEK-COATED,AS-AP Who Can Order Status Service Manual |
Part
074122 – 10-port valve with mounting bracket
+
|
Part Number
074122
📋
Copied
Part Description 10-port valve with mounting bracket SAP Part Description PROD,ASSY,VLV,RHEO,2/10,TITAN-HP,PK Who Can Order Status Service Manual |
Part
074123 – 6-port valve with mounting bracket
+
|
Part Number
074123
📋
Copied
Part Description 6-port valve with mounting bracket SAP Part Description PROD,ASSY,VLV,RHEO,2/6,TITAN-HP,PK Who Can Order Status Service Manual |
Part
074304 – AS-AP 3-Way Syringe Valve
+
|
Part Number
074304
📋
Copied
Part Description AS-AP 3-Way Syringe Valve SAP Part Description VLV,3 WAY,KLOEHN,AS-AP Who Can Order Status Service Manual |
Part
074305 – Syringe, 100 µL
+
|
Part Number
074305
📋
Copied
Part Description Syringe, 100 µL SAP Part Description SYRINGE,100 uL,AS-AP Who Can Order Status Service Manual |
Part
074306 – Syringe, 250 µL
+
|
Part Number
074306
📋
Copied
Part Description Syringe, 250 µL SAP Part Description SYRINGE,250 uL,AS-AP Who Can Order Status Service Manual |
Part
074307 – Syringe, 1000 µL
+
|
Part Number
074307
📋
Copied
Part Description Syringe, 1000 µL SAP Part Description SYRINGE,1 mL,AS-AP Who Can Order Status Service Manual |
Part
074308 – Syringe, 5000 µL
+
|
Part Number
074308
📋
Copied
Part Description Syringe, 5000 µL SAP Part Description SYRINGE,5 mL,AS-AP Who Can Order Status Service Manual |
Category
Accessory
+
Category
Cable
+
Part
043598 – Twisted pair of wires (for relay and TLL connections)
+
|
Part Number
043598
📋
Copied
Part Description Twisted pair of wires (for relay and TLL connections) SAP Part Description ASSY,WIRE,TWPR,96IN+BAG Who Can Order Status |
Part
923686 – 12-position connector plug (for relay connections)
+
|
Part Number
923686
📋
Copied
Part Description 12-position connector plug (for relay connections) SAP Part Description CONN,1X12POS,PLUG,MINI-COMB Who Can Order Status |
Part
924133 – 8-position connector plug (for TTL connections)
+
Part
960777 – USB cable, 6 ft
+
|
Part Number
960777
📋
Copied
Part Description USB cable, 6 ft SAP Part Description CBL,USB A/M TO B/M,6FT,RoHS Who Can Order Status Service Manual |
Category
Fittings
+
Part
043275 – Fitting bolt, 10-32, black
+
|
Part Number
043275
📋
Copied
Part Description Fitting bolt, 10-32, black SAP Part Description FTG,BOLT,10-32,DBL CONE Who Can Order Status Service Manual |
Part
043276 – Ferrule, 10-32 double-cone, tan
+
|
Part Number
043276
📋
Copied
Part Description Ferrule, 10-32 double-cone, tan SAP Part Description FTG,FER,DBL CONE,P-1 Who Can Order Status Service Manual |
Part
048949 – Ferrule, 1/8 in flangeless, yellow
+
|
Part Number
048949
📋
Copied
Part Description Ferrule, 1/8 in flangeless, yellow SAP Part Description FTG,FER,FLNGLS,1/8 TFZL,RoHS Who Can Order Status Service Manual Notes Wash reservoir line to syringe valve |
Part
052230 – Fitting nut, 1/16 in flangeless, tan
+
|
Part Number
052230
📋
Copied
Part Description Fitting nut, 1/16 in flangeless, tan SAP Part Description FTG,NUT,FLNGLS,1/4-28X1/16,PK,RoHS Who Can Order Status Service Manual Notes Buffer line to needle (push modes) |
Part
057934 – Fitting nut, 1/8 in flangeless (short), tan
+
|
Part Number
057934
📋
Copied
Part Description Fitting nut, 1/8 in flangeless (short), tan SAP Part Description FTG,NUT,FLGLS,SHORT,1/4-28X1/8 PK Who Can Order Status Service Manual Notes Wash reservoir line to syringe valve |
Part
062511 – Ferrule, two-piece (clear cone and tan flat)
+
|
Part Number
062511
📋
Copied
Part Description Ferrule, two-piece (clear cone and tan flat) SAP Part Description FTG,FER,TFZ,+PK LK RNG,2PC,RoHS Who Can Order Status Service Manual Notes • Waste line to syringe valv • Buffer line to syringe valve • Buffer line to needle (push modes) |
Part
062978 – Ferrule, split cone, black
+
|
Part Number
062978
📋
Copied
Part Description Ferrule, split cone, black SAP Part Description FTG,FER,SPLT CONE,PK,RoHS Who Can Order Status Service Manual Notes Sample transfer line to injection port (push modes • Needle to needle holder |
Part
062980 – Fitting bolt, 10-32, black
+
|
Part Number
062980
📋
Copied
Part Description Fitting bolt, 10-32, black SAP Part Description FTG,BOLT,10-32,1/4"HEX,SPLT FER,PK Who Can Order Status Service Manual Notes Sample transfer line to injection port (push modes |
Part
071358 – Fitting nut, 1/16 in flangeless (short), tan
+
|
Part Number
071358
📋
Copied
Part Description Fitting nut, 1/16 in flangeless (short), tan SAP Part Description FTG,NUT,FLGLS,SHORT,1/4-28X1/16,PK,RoHS Who Can Order Status Service Manual Notes • Waste line to syringe valv • Buffer line to syringe valve |
Part
074322 – Fitting bolt, 10-32, short thumb head, black
+
|
Part Number
074322
📋
Copied
Part Description Fitting bolt, 10-32, short thumb head, black SAP Part Description FTG,SHORT THUMB HEAD,10-32,PK,RoHS Who Can Order Status Service Manual Notes Needle to needle holder |
Part
074373 – Ferrule, high-pressure, 10-32 double-cone, blue
+
|
Part Number
074373
📋
Copied
Part Description Ferrule, high-pressure, 10-32 double-cone, blue SAP Part Description FTG,FERRULE,DBL CONE,HP Who Can Order Status Service Manual Notes Sample transfer line to injection valve, diverter valve, or Y_x0002_connecto |
Part
074449 – Fitting bolt, high-pressure, 10-32, blue
+
|
Part Number
074449
📋
Copied
Part Description Fitting bolt, high-pressure, 10-32, blue SAP Part Description FTG, BOLT, 10-32, DBL CONE, HP Who Can Order Status Service Manual Notes Sample transfer line to injection valve, diverter valve, or Y_x0002_connecto |
Category
Option
+
Part
075008 – AS-AP Simultaneous Injection Kit
+
|
Part Number
075008
📋
Copied
Part Description AS-AP Simultaneous Injection Kit SAP Part Description ASSY, KIT, PLUMB, SIM, AS-AP Who Can Order Status Service Manual |
Part
075010 – Degas tee kit (for online degassing of wash liquid)
+
|
Part Number
075010
📋
Copied
Part Description Degas tee kit (for online degassing of wash liquid) SAP Part Description KIT, 1/8' DEGAS LINE, AS-AP Who Can Order Status |
Category
Plates
+
Part
066330 – Well plate covers for 2mL well plates (package of 10)
+
|
Part Number
066330
📋
Copied
Part Description Well plate covers for 2mL well plates (package of 10) SAP Part Description WELL-CAPS,96-SQUARE,2.0ML,SILICONE,10 PK Who Can Order Status |
Part
066332 – Well plates, 96 micro-well, 0.5 mL round (U-shaped)
wells (package of 10) (not suitable for IC applications)
+
|
Part Number
066332
📋
Copied
Part Description Well plates, 96 micro-well, 0.5 mL round (U-shaped)
wells (package of 10) (not suitable for IC applications) SAP Part Description WELL-PLATE,96-WELL,0.5ML,PP,10 PK Who Can Order Status |
Part
066333 – Well plates, 96 micro-well, 0.45 mL conical (V-shaped)
wells (package of 20) (not suitable for IC applications)
+
|
Part Number
066333
📋
Copied
Part Description Well plates, 96 micro-well, 0.45 mL conical (V-shaped)
wells (package of 20) (not suitable for IC applications) SAP Part Description WELL-PLATE,96 WELLS V,0.45ML,PP,20PK Who Can Order Status |
Part
066334 – Well plates, 96 deep-well, 2mL wells (package of 5)
(suitable for IC applications, where concentration of
ions is above 1ppm)
+
|
Part Number
066334
📋
Copied
Part Description Well plates, 96 deep-well, 2mL wells (package of 5)
(suitable for IC applications, where concentration of
ions is above 1ppm) SAP Part Description WELL-PLATE,96-WELLSINUIN,2.0ML,PP,5 PACK Who Can Order Status |
Part
066335 – Well plate covers for 0.45mL and 0.5mL well plates
(package of 10)
+
|
Part Number
066335
📋
Copied
Part Description Well plate covers for 0.45mL and 0.5mL well plates
(package of 10) SAP Part Description WELL-CAPS,96-ROUND,2.0ML,SILICONE,10 PK Who Can Order Status |
Category
PM Kit
+
Part
075000 – AS-AP Preventive Maintenance Kit
+
|
Part Number
075000
📋
Copied
Part Description AS-AP Preventive Maintenance Kit SAP Part Description KIT, PM, AS-AP Who Can Order Status Service Manual |
Category
Sampler parts
+
Part
014067 – Syringe Valve Gasket
+
|
Part Number
014067
📋
Copied
Part Description Syringe Valve Gasket SAP Part Description O-RING,-012,0.364X.070 EPR Who Can Order Status Service Manual Notes White O-Ring for Syringe and Syringe Valve |
Category
Syringe
+
Part
055058 – Vials, 10mL polystyrene, with caps and septa (package
of 100)
+
|
Part Number
055058
📋
Copied
Part Description Vials, 10mL polystyrene, with caps and septa (package
of 100) SAP Part Description Vial Kt 10mL Polystyrene-CapsSepta 100ea Who Can Order Status Service Manual |
Category
System Module
+
Part
074921 – AS-AP Autosampler (excludes trays and vials)
+
|
Part Number
074921
📋
Copied
Part Description AS-AP Autosampler (excludes trays and vials) SAP Part Description AS-AP Autosampler, Base Configuration Who Can Order Status |
Part
074926 – AS-AP Autosampler (Tray Temperature Control)
+
|
Part Number
074926
📋
Copied
Part Description AS-AP Autosampler (Tray Temperature Control) SAP Part Description PROD,AS-AP AUTOSAMPLER,TEMP Who Can Order Status |
Part
079656 – AS-AP Autosampler (includes 3 10mL trays and vials)
+
|
Part Number
079656
📋
Copied
Part Description AS-AP Autosampler (includes 3 10mL trays and vials) SAP Part Description PROD,AS-AP,+10ML RACKS,VIALS Who Can Order Status |
Category
Tray
+
Part
069877 – Tray (wedge-shaped), for 10mL vials, 8-vial capacity
+
|
Part Number
069877
📋
Copied
Part Description Tray (wedge-shaped), for 10mL vials, 8-vial capacity SAP Part Description RACK,8 VIAL,AS-AP Who Can Order Status Service Manual |
Category
Tubing
+
Part
042690 – Tubing, 0.25-mm (0.010-in) ID PEEK, black
+
|
Part Number
042690
📋
Copied
Part Description Tubing, 0.25-mm (0.010-in) ID PEEK, black SAP Part Description TUBING,0.010IDx0.062OD,PK,BLK,RoHS Who Can Order Status |
Part
044777 – Tubing, 0.75 mm (0.030 in) ID PEEK, green
+
|
Part Number
044777
📋
Copied
Part Description Tubing, 0.75 mm (0.030 in) ID PEEK, green SAP Part Description TUBING,.030X.062 PK,GRN Who Can Order Status Service Manual Notes Sold in 1 inch units •Syringe valve to waste port: 75 mm (30 in) • 500 μL buffer line: 109 cm (43 in) • 1200 μL buffer line: 264 cm (104 in) • Injection valve to waste port (push modes): length depends on system |
Part
049714 – Tubing, 0.33 mm (0.013 in) ID PEEK, blue
+
|
Part Number
049714
📋
Copied
Part Description Tubing, 0.33 mm (0.013 in) ID PEEK, blue SAP Part Description TUBING,.013X.062 PK,BLU Who Can Order Status Service Manual Notes Sold in 1 inch units • Sample transfer lines (length varies depending on system) • Fraction collection valve to needle • Bridge line (fraction collection valve to injection valve) |
Part
052112 – Tubing, 1.55 mm (0.062 in) ID PFA, colorless
+
|
Part Number
052112
📋
Copied
Part Description Tubing, 1.55 mm (0.062 in) ID PFA, colorless SAP Part Description TUBING,.062X.125 PFA Who Can Order Status Service Manual Notes Wash reservoir to syringe valve: 75 mm (30 in) |
Part
055075 – Drain tube, 122 cm (48 in)
+
|
Part Number
055075
📋
Copied
Part Description Drain tube, 122 cm (48 in) SAP Part Description HOSE,CONVOLUTED,10MM IDX4FT PE Who Can Order Status |
Part
074982 – Drain tube extension, 20 cm (8 in) (for sample
temperature control)
+
|
Part Number
074982
📋
Copied
Part Description Drain tube extension, 20 cm (8 in) (for sample
temperature control) SAP Part Description T-PIECE,UPPER, 0.25MM,DUAL GRAD,ULT Who Can Order Status |
Part
074994 – Buffer line, 500μL
+
|
Part Number
074994
📋
Copied
Part Description Buffer line, 500μL SAP Part Description TUBING, 500UL BUFFER LOOP, AS-AP Who Can Order Status Service Manual Notes Syringe valve to needle |
Category
Valve
+
Part
AAA-061759 – Valve Rebuild Kit (for 10-port high-pressure valves)
+
|
Part Number
AAA-061759
📋
Copied
Part Description Valve Rebuild Kit (for 10-port high-pressure valves) SAP Part Description KIT,REBUILD,VLV,10 PORT,RHEO Who Can Order Status Service Manual |
Category
Vials
+
Part
055428 – Vials, 0.3mL polypropylene, with caps and septa
(package of 100)
+
|
Part Number
055428
📋
Copied
Part Description Vials, 0.3mL polypropylene, with caps and septa
(package of 100) SAP Part Description PROD,VIAL+CAP+SLIT SEPTA,0.3ML X 100 Who Can Order Status Service Manual |
Part
074228 – Vials, 10 mL polystyrene, with caps and septa for
capillary systems or trace analysis applications
(package of 100)
+
|
Part Number
074228
📋
Copied
Part Description Vials, 10 mL polystyrene, with caps and septa for
capillary systems or trace analysis applications
(package of 100) SAP Part Description PROD,ASSY,VIAL,KIT,10ML,PLAS,CAP,PK/100 Who Can Order Status Service Manual |
Part
074927 – Sealing disks, Teflon, for 10 mL vials
+
|
Part Number
074927
📋
Copied
Part Description Sealing disks, Teflon, for 10 mL vials SAP Part Description PROD,SEALING DISKS,TFE,10ML,PK/100 Who Can Order Status Service Manual |
Part
AAA-061696 – Vials, 1.5mL polypropylene, with caps and septa
(package of 100)
+
|
Part Number
AAA-061696
📋
Copied
Part Description Vials, 1.5mL polypropylene, with caps and septa
(package of 100) SAP Part Description VIAL,KIT,1.5ML,PPE,+CAPS +SEPTA,PKG/100 Who Can Order Status Service Manual |
AS-DV
+
Category
System
+
Part
037513 – Plunger Tip
+
|
Part Number
037513
📋
Copied
Part Description Plunger Tip SAP Part Description TIP,PLUNGER,AS40/ASM Who Can Order Service Status Active |
Part
037750 – Lead Nut
+
|
Part Number
037750
📋
Copied
Part Description Lead Nut SAP Part Description NUT,LEAD,1/4-20 VEE PLS Who Can Order Service Status Active |
Part
043598 – Twisted Wire Pair
+
Part
045683 – SST Phillips Pan Screw (M3-0.50x6mm)
+
|
Part Number
045683
📋
Copied
Part Description SST Phillips Pan Screw (M3-0.50x6mm) SAP Part Description SCR,M03X0.50X006,PAN,PHL,SST,RoHS Who Can Order Service Status Active |
Part
045689 – SST Washer, FL 3.2X7.0X 0.5 M3
+
|
Part Number
045689
📋
Copied
Part Description SST Washer, FL 3.2X7.0X 0.5 M3 SAP Part Description WSHR,FL? 3.2X7.0X 0.5 M3?? SST Who Can Order Service Status Active |
Part
049649 – SCR, M03 X0.50X0
+
|
Part Number
049649
📋
Copied
Part Description SCR, M03 X0.50X0 SAP Part Description SCW,FLT,PH,M3x8mm,SS,RoHS Who Can Order Service Status Active |
Part
050481 – SCR, M04 X0.70X0
+
|
Part Number
050481
📋
Copied
Part Description SCR, M04 X0.70X0 SAP Part Description SCR,M04 X0.70X008,CAP,SOC,SST Who Can Order Service Status Active |
Part
053913 – BELT, TMNG..08P,2
+
|
Part Number
053913
📋
Copied
Part Description BELT, TMNG..08P,2 SAP Part Description BELT,TMNG,.08P,23.6L,295G,1/4W Who Can Order Service Status Active |
Part
055075 – 10 mm Convoluted Hose
+
|
Part Number
055075
📋
Copied
Part Description 10 mm Convoluted Hose SAP Part Description HOSE,CONVOLUTED,10MM IDX4FT PE Who Can Order Customer and Service Status Active Service Manual |
Part
068396 – AS-DV Guide Rod
+
|
Part Number
068396
📋
Copied
Part Description AS-DV Guide Rod SAP Part Description ROD,GUIDE,AS-DV Who Can Order Service Status Active |
Part
068397 – AS-DV Plunger Head
+
|
Part Number
068397
📋
Copied
Part Description AS-DV Plunger Head SAP Part Description HEAD,PLUNGER,AS-DV Who Can Order Service Status Active |
Part
068404 – AS-DV Lead Screw
+
|
Part Number
068404
📋
Copied
Part Description AS-DV Lead Screw SAP Part Description SCR,LEAD,AS-DV Who Can Order Service Status Active |
Part
068859 – AS-DV Motor Arm Assembly
+
|
Part Number
068859
📋
Copied
Part Description AS-DV Motor Arm Assembly SAP Part Description MOTOR ASSY,ARM,AS-DV Who Can Order Service Status Active |
Part
068864 – AS-DV Cable Kit
+
|
Part Number
068864
📋
Copied
Part Description AS-DV Cable Kit SAP Part Description KIT,CBL,AS-DV Who Can Order Service Status Active |
Part
068871 – Top Cover
+
Part
068874 – Receiver Sensor Bracket
+
|
Part Number
068874
📋
Copied
Part Description Receiver Sensor Bracket SAP Part Description BRKT,SNSR,RX,TX,AS-DV Who Can Order Service Status Active |
Part
068875 – AS-DV Mounting Block
+
|
Part Number
068875
📋
Copied
Part Description AS-DV Mounting Block SAP Part Description BLOCK,MOUNTING,AS-DV Who Can Order Service Status Active |
Part
068925 – Cap Removal Tool
+
Part
068927 – AS-DV Carousel Plate
+
|
Part Number
068927
📋
Copied
Part Description AS-DV Carousel Plate SAP Part Description PLATE,CAROUSEL,SPNDL+PLNGR,AS-DV Who Can Order Service Status Active Service Manual Notes Includes Spindle and Plunger |
Part
068944 – AS-DV Timing Belt
+
|
Part Number
068944
📋
Copied
Part Description AS-DV Timing Belt SAP Part Description BELT,TIMING.080P,122G,1/4W Who Can Order Service Status Active |
Part
068944 – Motor Belt
+
Part
069204 – Main Board
+
|
Part Number
069204
📋
Copied
Part Description Main Board SAP Part Description PCB ASSY,CPU,AS-DV,NPB Who Can Order Service Status Active Service Manual |
Part
069315 – Receiver Sensor Board Assembly
+
|
Part Number
069315
📋
Copied
Part Description Receiver Sensor Board Assembly SAP Part Description PCB ASSY,RX,AS-DV,NPB Who Can Order Service Status Active Service Manual |
Part
069317 – Transmitter Sensor Board
+
|
Part Number
069317
📋
Copied
Part Description Transmitter Sensor Board SAP Part Description PCB ASSY,TX,AS-DV,NPB Who Can Order Service Status Active Service Manual |
Part
071568 – AS-DV Door Assembly
+
|
Part Number
071568
📋
Copied
Part Description AS-DV Door Assembly SAP Part Description ASSY,DOOR,AS-DV Who Can Order Service Status Active |
Part
071570 – Carousel Assembly (includes Motor and Pulley)
+
|
Part Number
071570
📋
Copied
Part Description Carousel Assembly (includes Motor and Pulley) SAP Part Description ASSY,CAROUSEL MTR+PULLEY,AS-DV Who Can Order Service Status Active Service Manual |
Part
071571 – AS-DV Needle Assembly
+
|
Part Number
071571
📋
Copied
Part Description AS-DV Needle Assembly SAP Part Description ASSY,NEEDLE,AS-DV Who Can Order Service Status Active Service Manual |
Part
071572 – AS-DV Arm Motor + Pulley Assembly
+
|
Part Number
071572
📋
Copied
Part Description AS-DV Arm Motor + Pulley Assembly SAP Part Description ASSY,ARM MOTOR+PULLEY,AS-DV Who Can Order Service Status Active |
Part
071573 – AS-DV Carousel Spindle + Plate Assembly
+
|
Part Number
071573
📋
Copied
Part Description AS-DV Carousel Spindle + Plate Assembly SAP Part Description ASSY,CAROUSEL SPINDL+PLT,AS-DV Who Can Order Service Status Active |
Part
071575 – Sample tip assembly
+
|
Part Number
071575
📋
Copied
Part Description Sample tip assembly SAP Part Description ASSY,TIP,SAMPLE,AS-DV Who Can Order Customer and Service Status Active Service Manual |
Part
60-046253 – SCR, M04 X0.70X0
+
|
Part Number
60-046253
📋
Copied
Part Description SCR, M04 X0.70X0 SAP Part Description SCR,M04 X0.70X014,CAP,SOC,SST Who Can Order Service Status Active |
Part
60-069313 – Display Board Assembly
+
Part
60-076861 – Carousel Assembly
+
|
Part Number
60-076861
📋
Copied
Part Description Carousel Assembly SAP Part Description CAROUSEL,ASSY,AS-DV Who Can Order Service Status Active Service Manual |
Part
940072 – Power Supply Assembly
+
|
Part Number
940072
📋
Copied
Part Description Power Supply Assembly SAP Part Description PWR SPY,45W,+5V,+24V,UNIV IN,RoHS Who Can Order Service Status Active Service Manual |
Part
954745 – Fuse
+
|
Part Number
954745
📋
Copied
Part Description Fuse SAP Part Description FUSE,3.15A,IEC,FAST,HIBRK,5X20,RoHS Who Can Order Customer and Service Status Active Service Manual |
Category
Tools
+
Part
037987 – PolyVial Cap Insertion Tool
+
|
Part Number
037987
📋
Copied
Part Description PolyVial Cap Insertion Tool SAP Part Description TOOL,AID,AS40/ASM Who Can Order Customer and Service Status Active Service Manual |
Category
Caps, Vials and Trays
+
Part
038008 – 5.0 ML PolyVials
+
|
Part Number
038008
📋
Copied
Part Description 5.0 ML PolyVials SAP Part Description PROD,D3,VIAL,5.0ML,250/BX Who Can Order Customer and Service Status Active Notes Vials Only |
Part
038009 – 5.0 ML Polyvial Filtered Caps
+
|
Part Number
038009
📋
Copied
Part Description 5.0 ML Polyvial Filtered Caps SAP Part Description PROD,D3,FLTRCAP,5.0ML,250/BX Who Can Order Customer and Service Status Active Notes Filtered Caps Only |
Part
038010 – 0.5 ML PolyVials
+
|
Part Number
038010
📋
Copied
Part Description 0.5 ML PolyVials SAP Part Description PROD,D3,VIAL,0.5ML,250/BX Who Can Order Customer and Service Status Active Notes Vials Only |
Part
038011 – 0.5 ML Polyvial Filtered Caps
+
|
Part Number
038011
📋
Copied
Part Description 0.5 ML Polyvial Filtered Caps SAP Part Description PROD,D3,FLTRCAP,0.5ML,250/BOX Who Can Order Customer and Service Status Active Notes Filtered Caps Only |
Part
038141 – 5.0 ML PolyVials + Caps (w/Filters)
+
|
Part Number
038141
📋
Copied
Part Description 5.0 ML PolyVials + Caps (w/Filters) SAP Part Description PolyVials+Filter Caps, 250 each, 5mL Who Can Order Customer and Service Status Active |
Part
038142 – 0.5 ML PolyVials + Caps (w/Filters)
+
|
Part Number
038142
📋
Copied
Part Description 0.5 ML PolyVials + Caps (w/Filters) SAP Part Description PolyVials+Filter Caps, 250 each, 0,5mL Who Can Order Customer and Service Status Active |
Part
039528 – 5.0 ML Polyvial Caps (no filter)
+
|
Part Number
039528
📋
Copied
Part Description 5.0 ML Polyvial Caps (no filter) SAP Part Description PROD,D3,CAP ,5ML,250/BX Who Can Order Customer and Service Status Active Notes Caps Without Filters Only |
Part
039532 – 5.0 ML PolyVials + Caps (No Filters)
+
|
Part Number
039532
📋
Copied
Part Description 5.0 ML PolyVials + Caps (No Filters) SAP Part Description PolyVials + Plain Caps, 5 mL, 250each Who Can Order Customer and Service Status Active |
Part
042014 – 0.5 ML PolyVials + Caps (No Filters)
+
|
Part Number
042014
📋
Copied
Part Description 0.5 ML PolyVials + Caps (No Filters) SAP Part Description PolyVials + Plain Caps, 0,5 mL, 250each Who Can Order Customer and Service Status Active |
Part
068947 – 5.0 ML Vial Sample Tray
+
|
Part Number
068947
📋
Copied
Part Description 5.0 ML Vial Sample Tray SAP Part Description TRAY,SAMPLE,5.0ML VIAL,AS-DV Who Can Order Customer and Service Status Active Service Manual |
Part
068948 – 0.5 ML Vial Sample Tray
+
|
Part Number
068948
📋
Copied
Part Description 0.5 ML Vial Sample Tray SAP Part Description TRAY,SAMPLE,0.5ML VIAL,AS-DV Who Can Order Customer and Service Status Active Service Manual |
Part
071901 – 0.5 ML Vial Adapter Kit
+
|
Part Number
071901
📋
Copied
Part Description 0.5 ML Vial Adapter Kit SAP Part Description KIT,VIAL ADP,0.5 ML (50 PC) Who Can Order Customer and Service Status Active Service Manual |
Part
079797 – 0.5 ML Polyvial Caps (no filter)
+
|
Part Number
079797
📋
Copied
Part Description 0.5 ML Polyvial Caps (no filter) SAP Part Description PROD,D3,CAP,- FLT,0.5ML,250 Who Can Order Customer and Service Status Active Notes Caps Without Filters Only |
Category
Option
+
Part
060258 – Simultaneous injection kit
+
|
Part Number
060258
📋
Copied
Part Description Simultaneous injection kit SAP Part Description PROD,KIT,SIMULTANEOUS INJ,AS-DV/AS40 Who Can Order Customer and Service Status Active Service Manual |
Category
PM Kit
+
Part
072678 – AS-DV PM Kit
+
|
Part Number
072678
📋
Copied
Part Description AS-DV PM Kit SAP Part Description ASSY,KIT,PM,AS/DV Who Can Order Customer and Service Status Active Service Manual |
Category
Ship Kit
+
Category
System Module
+
Part
B51004313 – AS-DV Autosampler
+
|
Part Number
B51004313
📋
Copied
Part Description AS-DV Autosampler SAP Part Description PROD,AS-DV,CH Who Can Order Status |
Part
B51004314 – AS-DV Autosampler w/0.5mL Adapaters
+
|
Part Number
B51004314
📋
Copied
Part Description AS-DV Autosampler w/0.5mL Adapaters SAP Part Description PROD,AS-DV W/ 0.5 ML VIAL ADAPTORS,CH Who Can Order Status |
ICS-6000 DC
+
Category
System
+
Part
00012-01-00052 –
+
|
Part Number
00012-01-00052
📋
Copied
Part Description SAP Part Description PWR SPY,90-264VAC,750W,24V,31.3A,RoHS Who Can Order Service Status Active |
Part
058053 – Leak sensor
+
Part
061811 – Analog Out I/O Relay PCB Board (excludes faceplate)
+
|
Part Number
061811
📋
Copied
Part Description Analog Out I/O Relay PCB Board (excludes faceplate) SAP Part Description ASSY,PCB,I/O,DCC,ICS3 (PCB without faceplate) Who Can Order Service Status Active Service Manual |
Part
061815 – Temperature Sensor PCB (Lower and Upper Compartment)
+
|
Part Number
061815
📋
Copied
Part Description Temperature Sensor PCB (Lower and Upper Compartment) SAP Part Description ASSY,PCB,DGTL SNSR,TEMP,ICS3/5 Who Can Order Service Status Active Service Manual |
Part
061823 –
+
|
Part Number
061823
📋
Copied
Part Description SAP Part Description ASSY,PCB,PREP,ICS3/5 Who Can Order Service Status Active |
Part
061855 – Rear Fan
+
|
Part Number
061855
📋
Copied
Part Description Rear Fan SAP Part Description ASSY,CBL,FAN,RR,DC,ICS3/5 Who Can Order Service Status Active Service Manual |
Part
061862 – Temperature cable assembly
+
|
Part Number
061862
📋
Copied
Part Description Temperature cable assembly SAP Part Description CBL,ASSY,BOT TEMP,DCC,ICS3/5 Who Can Order Service Status Active |
Part
061973 – Remote ON/OFF PCB
+
|
Part Number
061973
📋
Copied
Part Description Remote ON/OFF PCB SAP Part Description ASSY,PCB,ICS3000-REMOTE ON/OFF Who Can Order Service Status Active Service Manual |
Part
061988 – Bottom Door Sensor
+
|
Part Number
061988
📋
Copied
Part Description Bottom Door Sensor SAP Part Description ASSY,S/W,DOOR,BT,DCG,ICS3/5 (bottom door sensor) Who Can Order Service Status Active Service Manual |
Part
061989 – Top Door Sensor
+
|
Part Number
061989
📋
Copied
Part Description Top Door Sensor SAP Part Description ASSY,S/W,DOOR,TP,DCG,ICS3/5 (top door sensor) Who Can Order Service Status Active Service Manual |
Part
062181 – Compartment Door Hinge
+
|
Part Number
062181
📋
Copied
Part Description Compartment Door Hinge SAP Part Description HINGE,FRICTION,DC,REEL,RIGHT,ICS3/5 Who Can Order Service Status Active |
Part
062201 – Analog Out I/O Relay PCB Board (includes faceplate)
+
|
Part Number
062201
📋
Copied
Part Description Analog Out I/O Relay PCB Board (includes faceplate) SAP Part Description ASSY,PCB/FPLT,ANALOG,DC,ICS3/5 (PCB with faceplate) Who Can Order Service Status Active Service Manual |
Part
062226 –
+
Part
062227 – Upper Compartment Air Flow Fan
+
Part
062561 – Heat Exchanger Assembly (Standard Bore)
+
Part
062562 – Heat Exchanger (Microbore)
+
|
Part Number
062562
📋
Copied
Part Description Heat Exchanger (Microbore) SAP Part Description ASSY, HT EXCHGR, MB, ICS3/5 Who Can Order Customer and Service Status Active Service Manual |
Part
071414 – Cube Interconnect PCB
+
|
Part Number
071414
📋
Copied
Part Description Cube Interconnect PCB SAP Part Description PCB ASSY, CUBE INTERCONNECT, ICS5, NPB Who Can Order Service Status Active Service Manual |
Part
071416 – TEC PCB
+
|
Part Number
071416
📋
Copied
Part Description TEC PCB SAP Part Description PCB ASSY,TEC,ICS-5000,NPB Who Can Order Service Status Active |
Part
071641 – Upper Heat Exchanger
+
|
Part Number
071641
📋
Copied
Part Description Upper Heat Exchanger SAP Part Description THERM ELEC ASSY, AIR-TO-AIR, 95W, ICS5, DC5000 (upper TEC) Who Can Order Service Status Active Service Manual |
Part
072001 – IC Cube Assembly
+
|
Part Number
072001
📋
Copied
Part Description IC Cube Assembly SAP Part Description ASSY,IC-CUBE,ICS5000 Who Can Order Customer and Service Status Active Service Manual |
Part
072041 – Conductivity Detector Cell (Capillary)
+
|
Part Number
072041
📋
Copied
Part Description Conductivity Detector Cell (Capillary) SAP Part Description ASSY, CD DET/CELL, CAPILLARY, ICS5 Who Can Order Customer and Service Status Active Service Manual |
Part
072043 – Electrochemical Detector Assembly
+
|
Part Number
072043
📋
Copied
Part Description Electrochemical Detector Assembly SAP Part Description ASSY,EC DETECTOR,ICS5000 Who Can Order Customer and Service Status Active Service Manual |
Part
072044 – Electrochemical Detector Cell Body
+
Part
072056 –
+
|
Part Number
072056
📋
Copied
Part Description SAP Part Description PROD,CRD,BYPASS,ICS5000 Who Can Order Service Status Active |
Part
072160 – Electrochemical Cell Body
+
|
Part Number
072160
📋
Copied
Part Description Electrochemical Cell Body SAP Part Description BODY, EC CELL, ICS5 Who Can Order Customer and Service Status Active Service Manual |
Part
074079 – IC Cube Fan Assembly
+
|
Part Number
074079
📋
Copied
Part Description IC Cube Fan Assembly SAP Part Description FAN ASSY,IC CUBE,ICS4/5 Who Can Order Service Status Active Service Manual |
Part
074432 – Low pressure valve bracket
+
|
Part Number
074432
📋
Copied
Part Description Low pressure valve bracket SAP Part Description BRKT,LO PRESS,VLV,ICS5000 Who Can Order Service Status Active |
Part
075947 –
+
|
Part Number
075947
📋
Copied
Part Description SAP Part Description ASSY,VLV PNL,2VLV,DC,SB,ICS5+ Who Can Order Service Status Active |
Part
075948 –
+
|
Part Number
075948
📋
Copied
Part Description SAP Part Description ASSY,VLV PNL,1VLV,DC,MB,ICS5+ Who Can Order Service Status Active |
Part
075949 –
+
|
Part Number
075949
📋
Copied
Part Description SAP Part Description ASSY,VLV PNL,2VLV,DC,MB,ICS5+ Who Can Order Service Status Active |
Part
076038 – DC Front Plate PCB
+
|
Part Number
076038
📋
Copied
Part Description DC Front Plate PCB SAP Part Description ASSY, FRONT PANEL, DC, ICS5000 Who Can Order Service Status Active Service Manual |
Part
079829 – Conductivity Detector Cell (Analytical)
+
|
Part Number
079829
📋
Copied
Part Description Conductivity Detector Cell (Analytical) SAP Part Description ASSY,CD DET/CELL,ANALYTICAL,ICS3/5 Who Can Order Customer and Service Status Active Service Manual |
Part
079858 – Lower Heat Exchanger
+
|
Part Number
079858
📋
Copied
Part Description Lower Heat Exchanger SAP Part Description THERMAL ELECTRIC ASSY,DC (lower TEC) Who Can Order Service Status Active Service Manual |
Part
079912 – Column Tray Assembly
+
|
Part Number
079912
📋
Copied
Part Description Column Tray Assembly SAP Part Description ASSY,TRAY,COLUMN CAP,ICS5000 Who Can Order Service Status Active |
Part
22181-60031 – DC Consumable Device Monitor
+
|
Part Number
22181-60031
📋
Copied
Part Description DC Consumable Device Monitor SAP Part Description PROD,CONSUMABLE DEVICE MONITOR,DC (PN 22181-60030 with USB cable) Who Can Order Service Status Active Service Manual |
Part
22181-60520 – DC Power Supply Assembly (LT Version)
+
Part
22181-60521 – DC Power Supply Assembly (Standard Version)
+
|
Part Number
22181-60521
📋
Copied
Part Description DC Power Supply Assembly (Standard Version) SAP Part Description ASSY,PWR SPLY,DC STD Who Can Order Service Status Active Service Manual |
Part
22181-61002R – DC Suppressor PCB
+
|
Part Number
22181-61002R
📋
Copied
Part Description DC Suppressor PCB SAP Part Description ASSY,PCB,SUPPR-DCC Who Can Order Service Status Active Service Manual |
Part
22181-61004R – TEC Backplane Board
+
|
Part Number
22181-61004R
📋
Copied
Part Description TEC Backplane Board SAP Part Description ASSY,PCB,BACKPLANE,TEC Who Can Order Service Status Active Service Manual |
Part
22181-61005R – TEC Backplane PCB (LT Version)
+
|
Part Number
22181-61005R
📋
Copied
Part Description TEC Backplane PCB (LT Version) SAP Part Description ASSY,PCB,BACKPLANE,TEC,LT Who Can Order Service Status Active Service Manual |
Part
22181-61009R – DC CPU PCB (Main Board)
+
|
Part Number
22181-61009R
📋
Copied
Part Description DC CPU PCB (Main Board) SAP Part Description ASSY,PCB,CPU,DC Who Can Order Service Status Active Service Manual |
Part
22181-62016 – Tablet Arm/Holder Kit
+
|
Part Number
22181-62016
📋
Copied
Part Description Tablet Arm/Holder Kit SAP Part Description KIT,TABLET ARM/HOLDER,ICS-6000 Who Can Order Service Status Active |
Part
22181-62017 – Tablet Connectivity Cable Kit
+
|
Part Number
22181-62017
📋
Copied
Part Description Tablet Connectivity Cable Kit SAP Part Description KIT,CABLE,CONNECTIVITY,TABLET,ICS-6000 Who Can Order Service Status Active |
Part
940063 – Power Supply (320W, +24V)
+
|
Part Number
940063
📋
Copied
Part Description Power Supply (320W, +24V) SAP Part Description PWR SPY, 320W, +24V, UNIV IN Who Can Order Service Status Active |
Part
954772 – Slow Blow Fuse (10.00 AMP,250V)
+
|
Part Number
954772
📋
Copied
Part Description Slow Blow Fuse (10.00 AMP,250V) SAP Part Description FUSE,10.00 AMP,250V,SLOBLO,5X20 Who Can Order Customer and Service Status Active Service Manual |
Part
AAA-061803 –
+
|
Part Number
AAA-061803
📋
Copied
Part Description SAP Part Description ASSY,PCB,SRS-DCC,ICS-3/5000 Who Can Order Service Status Active |
Part
AAA-062225 – Safety Support Plate
+
|
Part Number
AAA-062225
📋
Copied
Part Description Safety Support Plate SAP Part Description SAFETY SUPPORT PLATE Who Can Order Service Status Active |
Category
Injection
+
Part
00110-03-00041 – 2 Position 4-Port Valve Pod (1 uL)
+
|
Part Number
00110-03-00041
📋
Copied
Part Description 2 Position 4-Port Valve Pod (1 uL) SAP Part Description VALVE,2-4,TITANHP,POD,PK,.1uL,RoHS Who Can Order Customer and Service Status Active |
Part
00110-03-00043 – 2 Position 4-Port Valve Rebuild Kit (1 uL)
+
|
Part Number
00110-03-00043
📋
Copied
Part Description 2 Position 4-Port Valve Rebuild Kit (1 uL) SAP Part Description VALVE,KIT,RHEBUILD,.1uL,INTLOOP,MHP,RoHS Who Can Order Customer and Service Status Active |
Part
00110-03-00044 – 2 Position 4-Port Valve Rebuild Kit (2 uL)
+
|
Part Number
00110-03-00044
📋
Copied
Part Description 2 Position 4-Port Valve Rebuild Kit (2 uL) SAP Part Description VALVE,KIT,RHEBUILD,.2uL,INTLOOP,MHP,RoHS Who Can Order Customer and Service Status Active |
Part
072050 – 4-port Valve (Internal loop 400nL)
+
|
Part Number
072050
📋
Copied
Part Description 4-port Valve (Internal loop 400nL) SAP Part Description VLV, 4PORT, 400 NL INT, PK, RHEO, TITAN Who Can Order Customer and Service Status Active Service Manual |
Part
074699 – 4-Port Valve Pod Assembly (Internal loop 400nL)
+
|
Part Number
074699
📋
Copied
Part Description 4-Port Valve Pod Assembly (Internal loop 400nL) SAP Part Description VLV POD ASSY,400nL, INT LOOP,RHEO,PK Who Can Order Customer and Service Status Active Service Manual |
Part
075917 – 6K 6-Port Valve
+
|
Part Number
075917
📋
Copied
Part Description 6K 6-Port Valve SAP Part Description VALVE,6PORT,PK,RHEO,TITAN,6K Who Can Order Customer and Service Status Active Service Manual |
Part
075971 – 6-Port Valve Pod Assembly
+
|
Part Number
075971
📋
Copied
Part Description 6-Port Valve Pod Assembly SAP Part Description VLV POD ASSY,6 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual |
Part
075972 – 10-Port Valve Pod Assembly
+
|
Part Number
075972
📋
Copied
Part Description 10-Port Valve Pod Assembly SAP Part Description VLV POD ASSY,10 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual |
Category
Eluent
+
Part
062510 – 2L Eluent Bottle
+
|
Part Number
062510
📋
Copied
Part Description 2L Eluent Bottle SAP Part Description ASSY, BTL, 2L, ELUENT, ICS3/5 Who Can Order Customer and Service Status Active Service Manual |
Category
Tools
+
Part
70-1844 – Tweezers (Anti-Static)
+
|
Part Number
70-1844
📋
Copied
Part Description Tweezers (Anti-Static) SAP Part Description TWEEZER 4-9/16IN X 1/8IN,ANTI-STATIC Who Can Order Service Status Active |
Category
Accessories
+
Part
061879 – Reference Electrode (AGCL)
+
|
Part Number
061879
📋
Copied
Part Description Reference Electrode (AGCL) SAP Part Description ELECTRODE ASSY, REF, AGCL Who Can Order Customer and Service Status Active Service Manual |
Part
072059 – Eluent Organizer Bottle Holder
+
|
Part Number
072059
📋
Copied
Part Description Eluent Organizer Bottle Holder SAP Part Description ASSY,HLDR,BTL,EO,ICS5000 Who Can Order Customer and Service Status Active |
Part
072161 – Capillary ED Working Electrode Gasket (PTFE; 1mil)
+
|
Part Number
072161
📋
Copied
Part Description Capillary ED Working Electrode Gasket (PTFE; 1mil) SAP Part Description GSKT, WE, PTFE, 1 MIL THK, CAP Who Can Order Customer and Service Status Active Service Manual |
Part
072162 – Capillary ED AG/AGCL Refrence Electrode Gasket
+
|
Part Number
072162
📋
Copied
Part Description Capillary ED AG/AGCL Refrence Electrode Gasket SAP Part Description GSKT, REF ELEC, AG/AGCL, CAP Who Can Order Customer and Service Status Active Service Manual |
Category
Fittings
+
Part
00101-01-00049 – Push-In Union Fitting
+
|
Part Number
00101-01-00049
📋
Copied
Part Description Push-In Union Fitting SAP Part Description FTG, UNION, PUSH-IN, 1/2", RoHS Who Can Order Customer and Service Status Active |
Part
00101-06-00010 – Push-In Union Tee Fitting
+
|
Part Number
00101-06-00010
📋
Copied
Part Description Push-In Union Tee Fitting SAP Part Description FTG, TEE, PUSH-IN, 1/2", RoHS Who Can Order Customer and Service Status Active |
Part
024305 – Luer Adapter Fitting
+
Part
043276 – Double Cone Ferrule Fitting
+
|
Part Number
043276
📋
Copied
Part Description Double Cone Ferrule Fitting SAP Part Description FTG, FERRULE, DBL CONE, HP Who Can Order Customer and Service Status Active |
Part
062623 – Bulkhead Union
+
|
Part Number
062623
📋
Copied
Part Description Bulkhead Union SAP Part Description UNION, BULKHD, MNL INJ, DC Who Can Order Customer and Service Status Active |
Part
071871 – Union Fitting 10-32 x 10-32
+
|
Part Number
071871
📋
Copied
Part Description Union Fitting 10-32 x 10-32 SAP Part Description FTG, UNION, 10-32 X 10-32,.007 THRU Who Can Order Customer and Service Status Active |
Part
074449 – Double Cone Bolt Fitting (10-32)
+
|
Part Number
074449
📋
Copied
Part Description Double Cone Bolt Fitting (10-32) SAP Part Description FTG, BOLT, 10-32, DBL CONE, HP Who Can Order Customer and Service Status Active |
Part
22000-98001 – PEEK Hex Bolt Fitting (10-32, 1/4)
+
|
Part Number
22000-98001
📋
Copied
Part Description PEEK Hex Bolt Fitting (10-32, 1/4) SAP Part Description FTG,BOLT,10-32,1/4 HEX,PEEK,NAT,RoHS Who Can Order Customer and Service Status Active |
Category
Kits
+
Part
064760 – Microbore DC/TC Spares Kit
+
|
Part Number
064760
📋
Copied
Part Description Microbore DC/TC Spares Kit SAP Part Description PROD, KIT, SPARES, MB, DC/TC Who Can Order Customer and Service Status Active |
Part
064761 – Standard Bore DC/TC Spares Kit
+
|
Part Number
064761
📋
Copied
Part Description Standard Bore DC/TC Spares Kit SAP Part Description PROD, KIT, SPARES, SB, DC/TC Who Can Order Customer and Service Status Active |
Part
072003 – IC Cube Ship Kit
+
|
Part Number
072003
📋
Copied
Part Description IC Cube Ship Kit SAP Part Description ASSY SHIPKIT, IC-CUBE, ICS5 Who Can Order Customer and Service Status Active |
Part
072011 – DC Ship Kit
+
|
Part Number
072011
📋
Copied
Part Description DC Ship Kit SAP Part Description ASSY, SHIPKIT, DC, ICS5 Who Can Order Customer and Service Status Active Service Manual |
Part
072186 – IC-Cube Tubing Kit
+
|
Part Number
072186
📋
Copied
Part Description IC-Cube Tubing Kit SAP Part Description KIT, TUBING, IC-CUBE, ICS5 Who Can Order Customer and Service Status Active Service Manual |
Part
074698 – 4-Port Valve Rebuild Kit
+
|
Part Number
074698
📋
Copied
Part Description 4-Port Valve Rebuild Kit SAP Part Description KIT,REBUILD,400nL, INT LOOP,RHEO,PK Who Can Order Customer and Service Status Active Service Manual |
Part
075973 – 6-Port Valve Rebuild Kit
+
|
Part Number
075973
📋
Copied
Part Description 6-Port Valve Rebuild Kit SAP Part Description KIT,REBUILD,VLV,6-PORT,6K Who Can Order Customer and Service Status Active Service Manual |
Part
079054 – 10-Port Valve Rebuild Kit
+
|
Part Number
079054
📋
Copied
Part Description 10-Port Valve Rebuild Kit SAP Part Description KIT,REBUILD,VLV,10-PORT,6K Who Can Order Customer and Service Status Active Service Manual |
Part
22181-62002 – DC Cable Kit
+
|
Part Number
22181-62002
📋
Copied
Part Description DC Cable Kit SAP Part Description KIT,CBL,DC,STD Who Can Order Service Status Active |
Part
AAA-061759 – 10-Port Valve Rebuild Assembly
+
|
Part Number
AAA-061759
📋
Copied
Part Description 10-Port Valve Rebuild Assembly SAP Part Description ASSY, REBUILD, VLV, 10 PORT, RHEO Who Can Order Customer and Service Status Active Service Manual |
Category
Misc Part
+
Part
062354 – DC Upper Latch Assembly
+
|
Part Number
062354
📋
Copied
Part Description DC Upper Latch Assembly SAP Part Description LATCH ASSY,DC,UPR,ICS3/5 Who Can Order Service Status Active |
Part
22181-60030 – DC Consumable Device Monitor PCB
+
|
Part Number
22181-60030
📋
Copied
Part Description DC Consumable Device Monitor PCB SAP Part Description ASSY,MON,DEVICE,CONSUMABLE,DC Who Can Order Service Status Active Service Manual |
Part
22181-60501 – Door/Frame Assembly
+
|
Part Number
22181-60501
📋
Copied
Part Description Door/Frame Assembly SAP Part Description ASSY,FRAME/DOORS, ICS6 Who Can Order Service Status Active |
Part
60-062501 – Adjustable Ball-Catch Latch Mechanism
+
|
Part Number
60-062501
📋
Copied
Part Description Adjustable Ball-Catch Latch Mechanism SAP Part Description CATCH,BALL,ADJ Who Can Order Service Status Active Service Manual |
Part
AAA-062225 – Safety Support Plate
+
|
Part Number
AAA-062225
📋
Copied
Part Description Safety Support Plate SAP Part Description SAFETY SUPPORT PLATE Who Can Order Service Status Active |
Category
PM Kit
+
Part
075040 – 4-Port Valve Preventative Maintenance Kit
+
|
Part Number
075040
📋
Copied
Part Description 4-Port Valve Preventative Maintenance Kit SAP Part Description ASSY,KIT,PM,.4uL INT LOOP VALVE Who Can Order Customer and Service Status Active Service Manual |
Part
075974 – 6-Port Valve Preventative Maintenance Kit
+
|
Part Number
075974
📋
Copied
Part Description 6-Port Valve Preventative Maintenance Kit SAP Part Description ASSY,KIT,PM,6-P0RT VALVE 6K Who Can Order Customer and Service Status Active Service Manual |
Part
079053 – 10-Port Valve Preventative Maintenance Kit
+
|
Part Number
079053
📋
Copied
Part Description 10-Port Valve Preventative Maintenance Kit SAP Part Description ASSY,KIT,PM,10-PORT VALVE 6K Who Can Order Customer and Service Status Active Service Manual |
Category
System Module
+
Part
22181-60041 – ICS-6000 DC (Dual Temperature Zones; 0 Injection Valves)
+
|
Part Number
22181-60041
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 0 Injection Valves) SAP Part Description PROD,DC-6000 STD TEMP,0 VALVE Who Can Order Customer and Service Status Active Notes Temp range: 18°C to 40°C Upper,10°C to 70°C Lower |
Part
22181-60043 – ICS-6000 DC (Dual Temperature Zones; 1 injection valve; Standard Bore)
+
|
Part Number
22181-60043
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 1 injection valve; Standard Bore) SAP Part Description PROD,DC-6000 STD TEMP,1 VALVE,STD-BORE Who Can Order Customer and Service Status Active Notes Temp range: 18°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60045 – ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Standard Bore)
+
|
Part Number
22181-60045
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Standard Bore) SAP Part Description PROD,DC-6000 STD TEMP,2 VALVE,STD-BORE Who Can Order Customer and Service Status Active Notes Temp range: 18°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60047 – ICS-6000 DC (Dual Temperature Zones; 1 Injection Valves; Microbore)
+
|
Part Number
22181-60047
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 1 Injection Valves; Microbore) SAP Part Description PROD,DC-6000 STD TEMP,1 VALVE,MICROBORE Who Can Order Customer and Service Status Active Notes Temp range: 18°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60049 – ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Microbore)
+
|
Part Number
22181-60049
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Microbore) SAP Part Description PROD,DC-6000 STD TEMP,2 VALVE,MICROBORE Who Can Order Customer and Service Status Active Notes Temp range: 18°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60051 – ICS-6000 DC (Dual Temperature Zones; 0 Injection Valves)
+
|
Part Number
22181-60051
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 0 Injection Valves) SAP Part Description PROD,DC-6000 LOW TEMP,0 VALVE Who Can Order Customer and Service Status Active Notes Temp range: 10°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60053 – ICS-6000 DC (Dual Temperature Zones; 1 Injection Valve; Standard Bore)
+
|
Part Number
22181-60053
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 1 Injection Valve; Standard Bore) SAP Part Description PROD,DC-6000 LOW TEMP,1 VALVE,STD-BORE Who Can Order Customer and Service Status Active Notes Temp range: 10°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60055 – ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Standard Bore)
+
|
Part Number
22181-60055
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Standard Bore) SAP Part Description PROD,DC-6000 LOW TEMP,2 VALVE,STD-BORE Who Can Order Customer and Service Status Active Notes Temp range: 10°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60057 – ICS-6000 DC (Dual Temperature Zones; 1 Injection Valve; Microbore)
+
|
Part Number
22181-60057
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 1 Injection Valve; Microbore) SAP Part Description PROD,DC-6000 LOW TEMP,1 VALVE,MICROBORE Who Can Order Customer and Service Status Active Notes Temp range: 10°C to 40°C Upper, 10°C to 70°C Lower |
Part
22181-60059 – ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Microbore)
+
|
Part Number
22181-60059
📋
Copied
Part Description ICS-6000 DC (Dual Temperature Zones; 2 Injection Valves; Microbore) SAP Part Description PROD,DC-6000 LOW TEMP,2 VALVE,MICROBORE Who Can Order Customer and Service Status Active Notes Temp range: 10°C to 40°C Upper, 10°C to 70°C Lower |
Category
Tubing
+
Part
055075 – Convoluted Hose (10mm ID x 4 FT)
+
|
Part Number
055075
📋
Copied
Part Description Convoluted Hose (10mm ID x 4 FT) SAP Part Description HOSE,CONVOLUTED,10MM IDX4FT PE Who Can Order Customer and Service Status Active Service Manual |
Part
062035 – Microbore tubing assembly (System 1)
+
|
Part Number
062035
📋
Copied
Part Description Microbore tubing assembly (System 1) SAP Part Description ASSY,TBG,MCR BORE,SYS1(WHT),DC Who Can Order Customer and Service Status Active |
Part
062036 – Microbore tubing assembly (System 2)
+
|
Part Number
062036
📋
Copied
Part Description Microbore tubing assembly (System 2) SAP Part Description ASSY, TBG, MCR BORE, SYS2 (BLU), DC Who Can Order Customer and Service Status Active |
Part
068658 – Damper-Out/EGC-IN Tubing Assembly
+
|
Part Number
068658
📋
Copied
Part Description Damper-Out/EGC-IN Tubing Assembly SAP Part Description TUBING ASSY, DAMPER-OUT/EGC-IN Who Can Order Customer and Service Status Active |
Part
072187 – 210mm precision cut tubing
+
Part
072188 – 65mm cut tubing for 250mm separator column
+
Part
072189 – 115mm cut tubing for 150mm separator column
+
Part
072203 – Precut Tubing assembly (24 inches; 0.0625 x 0.0025)
+
|
Part Number
072203
📋
Copied
Part Description Precut Tubing assembly (24 inches; 0.0625 x 0.0025) SAP Part Description ASSY, TUBING, 0.0625 X 0.0025, 24", PCUT Who Can Order Customer and Service Status Active |
Part
072204 – Precut Tubing assembly (6.75 inches; 0.0625 x 0.0025)
+
|
Part Number
072204
📋
Copied
Part Description Precut Tubing assembly (6.75 inches; 0.0625 x 0.0025) SAP Part Description ASSY,TUBING,0.0625X0.0025,6.75IN,PCUT Who Can Order Customer and Service Status Active |
Part
072224 – CRTC "Regen In" to "Degas Out"Tubing
+
|
Part Number
072224
📋
Copied
Part Description CRTC "Regen In" to "Degas Out"Tubing SAP Part Description TUBING ASSY, CRTC REG IN TO DEGAS OUT, 25"L, CAP Who Can Order Customer and Service Status Active |
Part
072225 – CRTC "Regen Out" to "Waste"Tubing
+
|
Part Number
072225
📋
Copied
Part Description CRTC "Regen Out" to "Waste"Tubing SAP Part Description TUBING ASSY, CRTC REG OUT TO WASTE, 7 FT, CAP Who Can Order Customer and Service Status Active |
Part
074221 –
+
|
Part Number
074221
📋
Copied
Part Description SAP Part Description ASSY, TUBING, PCUT,.0025X.062X6.75, +FTG, PK Who Can Order Customer and Service Status Active |
Part
074603 – Peek Tubing Assembly (0.0625 x 0.0025)
+
Part
22171-30002 –
+
|
Part Number
22171-30002
📋
Copied
Part Description SAP Part Description TUBING, 7/16"ID X 1/2"OD, PTFE, 13.0" LG Who Can Order Customer and Service Status Active |
Part
AAA-062031 – System 1 Tubing Assembly (Standard Bore)
+
|
Part Number
AAA-062031
📋
Copied
Part Description System 1 Tubing Assembly (Standard Bore) SAP Part Description ASSY,TBG,STD BORE,SYS1(WHT),DC Who Can Order Customer and Service Status Active |
ICS-6000 DP/SP
+
Category
Option Kit
+
Part
063518 – Dual-Serial External Seal Wash Kit
+
|
Part Number
063518
📋
Copied
Part Description Dual-Serial External Seal Wash Kit SAP Part Description PROD,SEAL,WASH,EXT'L,DUAL,SERIAL,KIT Who Can Order Service Status Active Service Manual |
Category
System
+
Part
00108-01-00046 – Vacuum Degas Pump (without bleed)
+
|
Part Number
00108-01-00046
📋
Copied
Part Description Vacuum Degas Pump (without bleed) SAP Part Description PUMP,VACUUM,DEGAS,WO BLEED,RoHS Who Can Order Service Status Active Service Manual |
Part
052719 – Eluent Tubing Assembly, Gradient Pump (4-Channel)
+
|
Part Number
052719
📋
Copied
Part Description Eluent Tubing Assembly, Gradient Pump (4-Channel) SAP Part Description ASSY, TBG, EL, 4 CHAN,GP40 Who Can Order Service Status Active |
Part
055075 – Convoluted Drain Hose
+
Part
058053 – Optical leak detector
+
|
Part Number
058053
📋
Copied
Part Description Optical leak detector SAP Part Description ASSY,LK DET,OPT Who Can Order Service Status Active |
Part
061868 – Leak Sensor
+
|
Part Number
061868
📋
Copied
Part Description Leak Sensor SAP Part Description CBL ASSY, EXT, LEAK SNSR, PMP,ICS-3/5 Who Can Order Service Status Active Service Manual |
Part
061869 – PS to CPU Cable Asssembly
+
|
Part Number
061869
📋
Copied
Part Description PS to CPU Cable Asssembly SAP Part Description CBL ASSY, DC, PS TOCPU, PMP,ICS-3000 Who Can Order Service Status Active |
Part
061901 – PS to CPU Controller Assembly
+
|
Part Number
061901
📋
Copied
Part Description PS to CPU Controller Assembly SAP Part Description CBL ASSY, CNTL, PS-CPU, PMP,ICS-3000 Who Can Order Service Status Active |
Part
061956 – Degas Assembly
+
|
Part Number
061956
📋
Copied
Part Description Degas Assembly SAP Part Description CBL ASSY, DGAS, PMP,ICS-3000 Who Can Order Service Status Active |
Part
061973 – Remote "On/Off" PCB
+
Part
062058 – Seal Wash Peristaltic Pump
+
|
Part Number
062058
📋
Copied
Part Description Seal Wash Peristaltic Pump SAP Part Description ASSY, SEAL WASH,PMP,ICS3/5 Who Can Order Service Status Active Service Manual |
Part
062060 – Pump Mechanism, Capillary
+
|
Part Number
062060
📋
Copied
Part Description Pump Mechanism, Capillary SAP Part Description PUMP DRIVE ASSY,SVC,ICS3/5 Who Can Order Service Status Active Service Manual |
Part
062463 – Pump Ship Kit
+
|
Part Number
062463
📋
Copied
Part Description Pump Ship Kit SAP Part Description ASSY, SHIPKIT, DP,ICS3/5 Who Can Order Customer and Service Status Active Service Manual |
Part
068668 – Pulse Damper
+
|
Part Number
068668
📋
Copied
Part Description Pulse Damper SAP Part Description ASSY, COIL, DAMPER,PUMP,ICS5000 Who Can Order Customer and Service Status Active Service Manual |
Part
069824 – CPU Board
+
|
Part Number
069824
📋
Copied
Part Description CPU Board SAP Part Description PCB ASSY,CPU,AUTOP680, NPB Who Can Order Service Status Active Service Manual |
Part
071254 – Power Supply PCB
+
|
Part Number
071254
📋
Copied
Part Description Power Supply PCB SAP Part Description PCB ASSY,PWRSPY,ICS3,NPB Who Can Order Service Status Active Service Manual |
Part
072111 – Dual Pump Ship Kit (Analytical)
+
|
Part Number
072111
📋
Copied
Part Description Dual Pump Ship Kit (Analytical) SAP Part Description ASSY, SHIPKIT, DP,STD-QUAT &CAP-ISO,+DGAS Who Can Order Customer and Service Status Active Service Manual |
Part
072112 – Dual Pump Ship Kit (Capillary)
+
|
Part Number
072112
📋
Copied
Part Description Dual Pump Ship Kit (Capillary) SAP Part Description ASSY, SHIPKIT, DP,CAP-ISO &CAP-ISO,+DGAS Who Can Order Customer and Service Status Active Service Manual |
Part
072907 – Damper Heater
+
|
Part Number
072907
📋
Copied
Part Description Damper Heater SAP Part Description ASSY, HEATED DAMPER Who Can Order Service Status Active |
Part
074438 – Front Panel PCB
+
|
Part Number
074438
📋
Copied
Part Description Front Panel PCB SAP Part Description PCB ASSY, FRNT PNL, EG, ICS5, NPB Who Can Order Service Status Active |
Part
074447 – Primary Pump Head (Capillary)
+
|
Part Number
074447
📋
Copied
Part Description Primary Pump Head (Capillary) SAP Part Description HEAD, PRIMARY, PUMP,CAP,HP(capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
074531 – Display Assembly, DP
+
|
Part Number
074531
📋
Copied
Part Description Display Assembly, DP SAP Part Description ASSY, DISPLAY, DP,PMP,ICS-5000 Who Can Order Service Status Active Service Manual |
Part
075372 – Proportioning Valve (Gradient only)
+
|
Part Number
075372
📋
Copied
Part Description Proportioning Valve (Gradient only) SAP Part Description VLV ASSY,PROP,TAKASAGO,DP-5000 Who Can Order Service Status Active Service Manual |
Part
075458 – Secondary pump head (capillary)
+
|
Part Number
075458
📋
Copied
Part Description Secondary pump head (capillary) SAP Part Description ASSY, HEAD, SEC, HI PRES, UPGRD, TESTED (capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
075956 – Isocratic pump replacement kit (ICS-5000 Plus)
+
|
Part Number
075956
📋
Copied
Part Description Isocratic pump replacement kit (ICS-5000 Plus) SAP Part Description ASSY,KIT,REPLACE,STD,ISO,PMP,ICS5+ Who Can Order Service Status Active |
Part
076806 – Degas Chamber, 4-channel (Gradient Pump)
+
|
Part Number
076806
📋
Copied
Part Description Degas Chamber, 4-channel (Gradient Pump) SAP Part Description CHAMBER, DEGAS, 4CH, PMP,ICS3/5 Who Can Order Service Status Active Service Manual |
Part
076849 – Pump Spares Kit (Gradient)
+
|
Part Number
076849
📋
Copied
Part Description Pump Spares Kit (Gradient) SAP Part Description PROD,KIT,SPARES,PMP,GRAD,ICS5+ Who Can Order Customer and Service Status Active |
Part
079649 – Pump Mechanism, Analytical
+
|
Part Number
079649
📋
Copied
Part Description Pump Mechanism, Analytical SAP Part Description ASSY,PUMP DRIVE,SVC,HPA,ICS5+ Who Can Order Service Status Active Service Manual |
Part
079911 – Pulse damper coil heater PCB
+
|
Part Number
079911
📋
Copied
Part Description Pulse damper coil heater PCB SAP Part Description PCB ASSY, PMPDMPRCOIL HTR, ICS5, NPB Who Can Order Service Status Active |
Part
079980 – Pump Spares Kit (Isocratic)
+
|
Part Number
079980
📋
Copied
Part Description Pump Spares Kit (Isocratic) SAP Part Description PROD,KIT,SPARES,PMP,ISO,ICS5+ Who Can Order Service Status Active |
Part
083477 – Primary Pump Head Assembly (Analytical)
+
|
Part Number
083477
📋
Copied
Part Description Primary Pump Head Assembly (Analytical) SAP Part Description HEADASSY,PRIMARY,PMP,ICS5+ Who Can Order Customer and Service Status Active Service Manual |
Part
083482 – Secondary pump head (analytical)
+
|
Part Number
083482
📋
Copied
Part Description Secondary pump head (analytical) SAP Part Description HEAD ASSY,SECONDARY,PMP,DP,SP Who Can Order Customer and Service Status Active Service Manual |
Part
60-061951 – Grounding Cable (4 inches)
+
|
Part Number
60-061951
📋
Copied
Part Description Grounding Cable (4 inches) SAP Part Description ASSY, CBL, GND, 4", 14AWG Who Can Order Service Status Active |
Part
940074 – Power Supply (45W,+24V)
+
|
Part Number
940074
📋
Copied
Part Description Power Supply (45W,+24V) SAP Part Description PWRSPY,45W,+24V,UNIV IN Who Can Order Service Status Active Service Manual |
Part
940076 – Power Supply (150W,+36V)
+
|
Part Number
940076
📋
Copied
Part Description Power Supply (150W,+36V) SAP Part Description PWRSPY,150W,+36V,UNIV IN Who Can Order Service Status Active Service Manual |
Part
954773 – Fuse, IEC 60127-2 slow-blow; rated at 2A, 250V
+
|
Part Number
954773
📋
Copied
Part Description Fuse, IEC 60127-2 slow-blow; rated at 2A, 250V SAP Part Description FUSE,2A,250V,SLOBLO,HI BRK,5X20,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
954776 – Main Fuses (2A, 250V, slow-blow)
+
|
Part Number
954776
📋
Copied
Part Description Main Fuses (2A, 250V, slow-blow) SAP Part Description FUSE,2.00 AMP,250V,SLOBLO,5X20,RoHS Who Can Order Service Status Active Service Manual |
Category
Eluent
+
Part
044105 – Filter, High-Pressure Inline (10-32)
+
|
Part Number
044105
📋
Copied
Part Description Filter, High-Pressure Inline (10-32) SAP Part Description PROD,FLTR,INLINE,10-32,HI PRES Who Can Order Customer and Service Status Active Service Manual |
Part
045987 – Filter, End-Line (1/4-28)
+
|
Part Number
045987
📋
Copied
Part Description Filter, End-Line (1/4-28) SAP Part Description FLTR,END-LINE,ELU,1/4-28 UHMW PE Who Can Order Customer and Service Status Active |
Part
049135 – GM-4 Static Mixer
+
|
Part Number
049135
📋
Copied
Part Description GM-4 Static Mixer SAP Part Description PROD,COL,IC,GM-4B,MB MIXER Who Can Order Customer and Service Status Active Service Manual |
Part
062510 – Eluent reservoir (plastic), 2-liter
+
|
Part Number
062510
📋
Copied
Part Description Eluent reservoir (plastic), 2-liter SAP Part Description ASSY,BTL,2L,ELUENT Who Can Order Customer and Service Status Active Service Manual |
Part
063291 – Eluent reservoir (plastic), 1-liter
+
|
Part Number
063291
📋
Copied
Part Description Eluent reservoir (plastic), 1-liter SAP Part Description ASSY,BTL,1L,ELUENT Who Can Order Customer and Service Status Active Service Manual |
Part
063292 – Eluent reservoir (plastic), 4-liter
+
|
Part Number
063292
📋
Copied
Part Description Eluent reservoir (plastic), 4-liter SAP Part Description ASSY,BTL,4L,2PORT,HDPE Who Can Order Customer and Service Status Active Service Manual |
Part
072057 – Eluent Organizer (Includes two 2-liter reservoirs)
+
|
Part Number
072057
📋
Copied
Part Description Eluent Organizer (Includes two 2-liter reservoirs) SAP Part Description PROD,EO+2 ELUENT BTLS Who Can Order Customer and Service Status Active Service Manual |
Part
072058 – Eluent Organizer (Includes four 2-liter reservoirs)
+
|
Part Number
072058
📋
Copied
Part Description Eluent Organizer (Includes four 2-liter reservoirs) SAP Part Description PROD,EO+4 ELUENT BTLS Who Can Order Customer and Service Status Active Service Manual |
Part
072059 – Eluent Organizer (EO) Bottle Holder
+
|
Part Number
072059
📋
Copied
Part Description Eluent Organizer (EO) Bottle Holder SAP Part Description ASSY,HLDR,BTL,EO Who Can Order Customer and Service Status Active Service Manual |
Part
074422 – EO Regulator
+
|
Part Number
074422
📋
Copied
Part Description EO Regulator SAP Part Description PROD, REG,EO ACCESSORY Who Can Order Customer and Service Status Active Service Manual |
Part
AAA-074423 – EO Regulator Accessory and Stand
+
|
Part Number
AAA-074423
📋
Copied
Part Description EO Regulator Accessory and Stand SAP Part Description PROD, REG,EO Who Can Order Customer and Service Status Active Service Manual |
Category
Accessory
+
Part
074424 – TC/VWD/PDA Regulator Bracket Kit
+
|
Part Number
074424
📋
Copied
Part Description TC/VWD/PDA Regulator Bracket Kit SAP Part Description PROD,BRKT,REG, TC/VWD/PDA, ICS5 Who Can Order Customer and Service Status Active Service Manual |
Part
079803 – Syringe, 10 cc
+
|
Part Number
079803
📋
Copied
Part Description Syringe, 10 cc SAP Part Description SYRINGE, 10CC, NON-STERILE, SLPTP Who Can Order Customer and Service Status Active |
Category
Tools
+
Part
063675 – Seal Insertion Tool
+
|
Part Number
063675
📋
Copied
Part Description Seal Insertion Tool SAP Part Description TOOL, INSERT, SEALHEAD, ICS3/5 Who Can Order Service Status Active Service Manual |
Category
Fittings
+
Part
042772 – Plug Fitting (10-32)
+
|
Part Number
042772
📋
Copied
Part Description Plug Fitting (10-32) SAP Part Description FTG,PLUG,10-32 BLK,P1 Who Can Order Customer and Service Status Active |
Part
043276 – Ferrule fitting, 10-32 double-cone
+
|
Part Number
043276
📋
Copied
Part Description Ferrule fitting, 10-32 double-cone SAP Part Description FTG, FERRULE, DBL CONE, HP Who Can Order Customer and Service Status Active |
Part
052230 – Fitting bolt, 1/16 in
+
|
Part Number
052230
📋
Copied
Part Description Fitting bolt, 1/16 in SAP Part Description FTG,NUT,FLNGLS,1/4-28X1/16,PK,RoHS Who Can Order Customer and Service Status Active |
Part
22000-98001 – Fitting bolt, 10-32 (for double-cone ferrule fitting)
+
|
Part Number
22000-98001
📋
Copied
Part Description Fitting bolt, 10-32 (for double-cone ferrule fitting) SAP Part Description FTG,BOLT,10-32,1/4 HEX,PEEK,NAT,RoHS Who Can Order Customer and Service Status Active |
Category
PM Kit
+
Part
075970 – DP/SP (Analytical) Annual Preventive Maintenance Kit
+
|
Part Number
075970
📋
Copied
Part Description DP/SP (Analytical) Annual Preventive Maintenance Kit SAP Part Description ASSY,KIT,PM,ANALYTICAL PUMP,ICS5+ Who Can Order Customer and Service Status Active Service Manual |
Category
Pump Parts
+
Part
040695 – O-ring (for capillary or analytical pump)
+
|
Part Number
040695
📋
Copied
Part Description O-ring (for capillary or analytical pump) SAP Part Description O-RING,-015,.551X.070,EM163-80,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
044540 – Outlet check valve assembly (for primary pump head - capillary); includes outlet nut and 1/8 in cartridge
+
|
Part Number
044540
📋
Copied
Part Description Outlet check valve assembly (for primary pump head - capillary); includes outlet nut and 1/8 in cartridge SAP Part Description ASSY,CK VLV,OT,MB,2B,PK (capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
044541 – Inlet check valve assembly (for primary pump head -capillary); includes inlet nut and 1/8 in cartridge
+
|
Part Number
044541
📋
Copied
Part Description Inlet check valve assembly (for primary pump head -capillary); includes inlet nut and 1/8 in cartridge SAP Part Description ASSY,CKVLV,IN,MB,2B,PK(capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
045721 – Outlet check valve assembly (for primary pump head - analytical); includes outlet nut and 1/8 in cartridge
+
|
Part Number
045721
📋
Copied
Part Description Outlet check valve assembly (for primary pump head - analytical); includes outlet nut and 1/8 in cartridge SAP Part Description ASSY,CK VLV,OT,SB,2B,GP/GS,PK Who Can Order Customer and Service Status Active Service Manual |
Part
045722 – Inlet check valve assembly (for primary pump head - analytical); includes inlet nut and 1/8 in cartridge
+
|
Part Number
045722
📋
Copied
Part Description Inlet check valve assembly (for primary pump head - analytical); includes inlet nut and 1/8 in cartridge SAP Part Description ASSY,CK VLV,IN,SB,2B,GP/GS,PK Who Can Order Customer and Service Status Active Service Manual |
Part
062087 – Priming ValveKnob, Secondary Pump Head (capillary or analytical pump)
+
|
Part Number
062087
📋
Copied
Part Description Priming ValveKnob, Secondary Pump Head (capillary or analytical pump) SAP Part Description BODY,VLV,PURGE,PMP,ICS-3000 Who Can Order Customer and Service Status Active Service Manual |
Part
062092 – Retainer for piston seal wash seal (analytical)
+
|
Part Number
062092
📋
Copied
Part Description Retainer for piston seal wash seal (analytical) SAP Part Description KEEPER,SEAL WASH,PMP Who Can Order Customer and Service Status Active Service Manual |
Part
063382 – Piston seal wash seal (analytical)
+
|
Part Number
063382
📋
Copied
Part Description Piston seal wash seal (analytical) SAP Part Description SEAL, WASH,DURON14 GOLD, 50809 (analytical) Who Can Order Customer and Service Status Active Service Manual Notes Seal is also used for the priming valve seal. |
Part
064155 – Piston Seal Wash Reservoir
+
|
Part Number
064155
📋
Copied
Part Description Piston Seal Wash Reservoir SAP Part Description BOTTLE,SEAL WASH,PMP Who Can Order Customer and Service Status Active Service Manual |
Part
068627 – Retainer for piston seal wash seal (capillary)
+
|
Part Number
068627
📋
Copied
Part Description Retainer for piston seal wash seal (capillary) SAP Part Description KEEPER, SEAL, 2MM (capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
068628 – Piston seal wash seal (capillary)
+
|
Part Number
068628
📋
Copied
Part Description Piston seal wash seal (capillary) SAP Part Description SEAL, RINSE, 2MM (capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
068646 – Sapphire Piston (capillary)
+
|
Part Number
068646
📋
Copied
Part Description Sapphire Piston (capillary) SAP Part Description PISTON, 2MM (capillary) Who Can Order Customer and Service Status Active Service Manual |
Part
074370 – Backup ring (analytical)
+
|
Part Number
074370
📋
Copied
Part Description Backup ring (analytical) SAP Part Description RING,BACKUP,SEAL,PUMP,HPA Who Can Order Customer and Service Status Active Service Manual |
Part
074371 – Backup ring (capillary)
+
|
Part Number
074371
📋
Copied
Part Description Backup ring (capillary) SAP Part Description RING,BACKUP,SEAL,PUMP,CAP HP Who Can Order Customer and Service Status Active Service Manual |
Part
074446 – Seal wash body (capillary)
+
|
Part Number
074446
📋
Copied
Part Description Seal wash body (capillary) SAP Part Description ASSY,SEAL WASH,PUMP,CAP,HP Who Can Order Customer and Service Status Active Service Manual |
Part
075493 – Main piston seal (capillary)
+
|
Part Number
075493
📋
Copied
Part Description Main piston seal (capillary) SAP Part Description SEAL,2MM,PUMP,HPC2,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
075767 – Seal wash body (analytical)
+
|
Part Number
075767
📋
Copied
Part Description Seal wash body (analytical) SAP Part Description ASSY,SEAL WASH, HPA Who Can Order Customer and Service Status Active Service Manual |
Part
075768 – Main piston seal (analytical)
+
|
Part Number
075768
📋
Copied
Part Description Main piston seal (analytical) SAP Part Description SEAL,.125 PISTON,PUMP,HPA,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
079857 – Sapphire Piston (analytical)
+
|
Part Number
079857
📋
Copied
Part Description Sapphire Piston (analytical) SAP Part Description PISTON,PMP,.1250,ICS3/5,SAPHIR (analytical) Who Can Order Customer and Service Status Active Service Manual |
Category
Sstem
+
Part
60-076807 – Degas Chamber, 1-channel (Isocratic Pump)
+
|
Part Number
60-076807
📋
Copied
Part Description Degas Chamber, 1-channel (Isocratic Pump) SAP Part Description CHAMBER,DEGAS,1CH,PMP,ICS5 Who Can Order Service Status Active Service Manual |
Category
System Module
+
Part
22181-60001 – ICS-6000 SP Single Pump (Analytical - Gradient + Degas)
+
|
Part Number
22181-60001
📋
Copied
Part Description ICS-6000 SP Single Pump (Analytical - Gradient + Degas) SAP Part Description PROD,SP,STD,QUAT,+DGAS,ICS6 Who Can Order Customer and Service Status Active |
Part
22181-60003 – ICS-6000 SP Single Pump (Analytical - Isocratic + Degas)
+
|
Part Number
22181-60003
📋
Copied
Part Description ICS-6000 SP Single Pump (Analytical - Isocratic + Degas) SAP Part Description PROD,SP,STD,ISO,+DGAS,ICS6 Who Can Order Customer and Service Status Active |
Part
22181-60007 – ICS-6000 DP Dual Pumps (Analytical - Gradient/Gradient + Degas)
+
|
Part Number
22181-60007
📋
Copied
Part Description ICS-6000 DP Dual Pumps (Analytical - Gradient/Gradient + Degas) SAP Part Description PROD,DP,STD,QUAT-QUAT,+DGAS,ICS6 Who Can Order Customer and Service Status Active |
Part
22181-60009 – ICS-6000 DP Dual Pumps (Analytical - Gradient/Isocratic + Degas)
+
|
Part Number
22181-60009
📋
Copied
Part Description ICS-6000 DP Dual Pumps (Analytical - Gradient/Isocratic + Degas) SAP Part Description PROD,DP,STD,QUAT-ISO,+DGAS,ICS6 Who Can Order Customer and Service Status Active |
Part
22181-60011 – ICS-6000 DP Dual Pumps (Analytical - Isocratic/Isocratic + Degas)
+
|
Part Number
22181-60011
📋
Copied
Part Description ICS-6000 DP Dual Pumps (Analytical - Isocratic/Isocratic + Degas) SAP Part Description PROD,DP,STD,ISO-ISO,+DGAS,ICS6 Who Can Order Customer and Service Status Active |
Category
Tubing
+
Part
063268 – PharMed tubing, 0.159 cm (0.0625 in) ID; Note: Order 12 in of tubing for replacement of piston seal wash tubing.
+
|
Part Number
063268
📋
Copied
Part Description PharMed tubing, 0.159 cm (0.0625 in) ID; Note: Order 12 in of tubing for replacement of piston seal wash tubing. SAP Part Description TUBING,0.0625 X 0.125,PHARMED Who Can Order Customer and Service Status Active Service Manual |
Category
Viper Tubing
+
Part
088916 – Viper assembly, 0.18 mm (0.007 in) ID, 864 mm (34.0 in)
+
|
Part Number
088916
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in) ID, 864 mm (34.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID,34.0"(864MM Who Can Order Customer and Service Status Active Service Manual |
Part
088917 – Viper assembly, 0.18 mm (0.007 in) ID, 178 mm (7.0 in)
+
|
Part Number
088917
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in) ID, 178 mm (7.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID,7.0"(178MM) Who Can Order Customer and Service Status Active Service Manual |
ICS-6000 EG
+
Category
System
+
Part
058053 – Leak Detector
+
|
Part Number
058053
📋
Copied
Part Description Leak Detector SAP Part Description ASSY,LK DET,OPT Who Can Order Service Status Active |
Part
062145 – EGC Face Plate PCB
+
|
Part Number
062145
📋
Copied
Part Description EGC Face Plate PCB SAP Part Description ASSY, EGC, PCB/FACEPLATE, ICS3/5000 Who Can Order Service Status Active Service Manual |
Part
074018 – EG Backplane PCB
+
|
Part Number
074018
📋
Copied
Part Description EG Backplane PCB SAP Part Description PCB ASSY, BACKPLANE, EG, ICS-5000, NPB Who Can Order Service Status Active Service Manual |
Part
074425 – Eluent Organizier Air Regulator Assembly
+
|
Part Number
074425
📋
Copied
Part Description Eluent Organizier Air Regulator Assembly SAP Part Description ASSY, AIR, REG, EO, ICS5000 Who Can Order Customer and Service Status Active Service Manual |
Part
074439 – EG LED Display Assembly
+
Part
22181-61003R – Dual EGC Drive PCB
+
|
Part Number
22181-61003R
📋
Copied
Part Description Dual EGC Drive PCB SAP Part Description ASSY,PCB,DRIVE,DUAL,EG+ Who Can Order Service Status Active Service Manual |
Part
22181-61010R – EG Main Board (CPU) PCB
+
|
Part Number
22181-61010R
📋
Copied
Part Description EG Main Board (CPU) PCB SAP Part Description ASSY,PCB,CPU,EG Who Can Order Service Status Active Service Manual |
Part
22181-62004 – EG Cable Kit
+
|
Part Number
22181-62004
📋
Copied
Part Description EG Cable Kit SAP Part Description KIT,CBL,EG Who Can Order Service Status Active |
Part
921633 – EG Fuse Drawer
+
|
Part Number
921633
📋
Copied
Part Description EG Fuse Drawer SAP Part Description FUSEDRAWER,2POLE,AC INLET,BLK Who Can Order Service Status Active |
Part
946061 – EG Main Power Supply
+
|
Part Number
946061
📋
Copied
Part Description EG Main Power Supply SAP Part Description PWR SPY, 65W, +24V, UNIV IN Who Can Order Service Status Active Service Manual |
Part
954776 – Fuse (2.00 AMP)
+
|
Part Number
954776
📋
Copied
Part Description Fuse (2.00 AMP) SAP Part Description FUSE,2.00 AMP,250V,SLOBLO,5X20 Who Can Order Customer and Service Status Active |
Category
Eluent
+
Part
062510 – Eluent Bottle (2L)
+
|
Part Number
062510
📋
Copied
Part Description Eluent Bottle (2L) SAP Part Description ASSY, BTL, 2L, ELUENT, IC3/5 Who Can Order Customer and Service Status Active |
Part
072059 – Bottle Holder Assembly (Eluent Organizer)
+
|
Part Number
072059
📋
Copied
Part Description Bottle Holder Assembly (Eluent Organizer) SAP Part Description ASST, HLDR, BTL, EO, ICS5000 Who Can Order Customer and Service Status Active Service Manual |
Category
EG Parts
+
Part
072047 – EG Module Ship Kit
+
|
Part Number
072047
📋
Copied
Part Description EG Module Ship Kit SAP Part Description ASSY,SHIPKIT,DUAL EG,ICS5000 Who Can Order Customer and Service Status Active |
Category
Fittings
+
Part
043276 – Double Cone Ferrule Fitting (P-1)
+
|
Part Number
043276
📋
Copied
Part Description Double Cone Ferrule Fitting (P-1) SAP Part Description FTG,FER,DBL CONE,P-1 Who Can Order Customer and Service Status Active |
Part
047799 – Barbed Fitting
+
Part
063351 – Bulkhead Union
+
Part
22000-98001 – 10-32 Peek Bolt Fitting
+
|
Part Number
22000-98001
📋
Copied
Part Description 10-32 Peek Bolt Fitting SAP Part Description FTG,BOLT,10-32,1/4 HEX,PEEK,NAT,RoHS Who Can Order Customer and Service Status Active |
Category
System Module
+
Part
22181-60019 – ICS-6000 EG Eluent Generator
+
|
Part Number
22181-60019
📋
Copied
Part Description ICS-6000 EG Eluent Generator SAP Part Description PROD,EG,DUAL,ISC6 Who Can Order Customer and Service Status Active |
Category
Tubing
+
Part
063487 – CR-TC Hydration Tubing Kit
+
|
Part Number
063487
📋
Copied
Part Description CR-TC Hydration Tubing Kit SAP Part Description KIT,TUBING, CR-TC HYDRATION Who Can Order Customer and Service Status Active Service Manual |
Part
063942 – EG Gas Source Tubing
+
|
Part Number
063942
📋
Copied
Part Description EG Gas Source Tubing SAP Part Description ASSY, TUBING, GAS SOURCE Who Can Order Customer and Service Status Active |
Integrion HPIC
+
Category
System
+
Part
00006-03-00016 – Fuse, 5 A, 250 V, 5 x 20 mm IEC 60127-2 fast-blow
+
|
Part Number
00006-03-00016
📋
Copied
Part Description Fuse, 5 A, 250 V, 5 x 20 mm IEC 60127-2 fast-blow SAP Part Description FUSE,5A,250V,5X20mm,FAST-ACT,HI-BRK,RoHS Who Can Order Customer and Service Status Active |
Part
00108-01-00046 – Vacuum Pump Only
+
|
Part Number
00108-01-00046
📋
Copied
Part Description Vacuum Pump Only SAP Part Description PUMP,VACUUM,DEGAS,WO BLEED,RoHS Who Can Order Service Status Active Service Manual |
Part
00302-99-00071 – USB Cable Between Pump CPU to Main CPU Board
+
|
Part Number
00302-99-00071
📋
Copied
Part Description USB Cable Between Pump CPU to Main CPU Board SAP Part Description CABLE, USB A TO RT ANGLE B,0.3M LG,RoHS Who Can Order Service Status Active |
Part
043598 – Twisted pair of wires assembly
+
|
Part Number
043598
📋
Copied
Part Description Twisted pair of wires assembly SAP Part Description ASSY,WIRE,TWPR,96IN+BAG Who Can Order Customer and Service Status Active |
Part
045460 – Gas Separator Waste Tube Assembly
+
|
Part Number
045460
📋
Copied
Part Description Gas Separator Waste Tube Assembly SAP Part Description WASTE SEPARATOR,ASSY,SRS Who Can Order Customer and Service Status Active Notes Part of the Integrion RFIC and NON-RFIC ship kit. |
Part
055075 – Corrugated Drain Line
+
|
Part Number
055075
📋
Copied
Part Description Corrugated Drain Line SAP Part Description HOSE,CONVOLUTED,10MM IDX4FT PE Who Can Order Customer and Service Status Active Notes Part of the Integrion RFIC and NON-RFIC ship kit. |
Part
064552 – Static mixer mounting clip
+
|
Part Number
064552
📋
Copied
Part Description Static mixer mounting clip SAP Part Description CLIP,COMP,.69,BLK PLASTIC,M3,RoHS Who Can Order Customer and Service Status Active Notes Included in the Integrion ship kit |
Part
074505 – High-pressure inline filter
+
|
Part Number
074505
📋
Copied
Part Description High-pressure inline filter SAP Part Description PROD,FLTR,INLINE,10-32,LOW VOLUME Who Can Order Customer and Service Status Active |
Part
079649 – Pump Motor w/o Metal Tray
+
|
Part Number
079649
📋
Copied
Part Description Pump Motor w/o Metal Tray SAP Part Description ASSY,PUMP DRIVE,SVC,HPA,ICS5+ Who Can Order Service Status Active Service Manual |
Part
22153-40103 – Compartment Foam Cover
+
|
Part Number
22153-40103
📋
Copied
Part Description Compartment Foam Cover SAP Part Description TAPE,FOAM,.125x4.75x6.8,A/F,DETCMPT,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-40107 – Magnet for mobile device
+
|
Part Number
22153-40107
📋
Copied
Part Description Magnet for mobile device SAP Part Description MAGNET SHEET,DISPLAY,INTEGRION Who Can Order Customer and Service Status Active |
Part
22153-60001 – Waste Line Tubing With Grounded Wire
+
|
Part Number
22153-60001
📋
Copied
Part Description Waste Line Tubing With Grounded Wire SAP Part Description ASSY,TUBING,PTFE EX,ITGN Who Can Order Service Status Active |
Part
22153-60006 – Cooled Detector Compartment (Whole Assembly)
+
|
Part Number
22153-60006
📋
Copied
Part Description Cooled Detector Compartment (Whole Assembly) SAP Part Description ASSY, DET CMPT COOLED, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60009 – Pump Motor with Pump Head, Shut Off Valve and Metal Tray
+
|
Part Number
22153-60009
📋
Copied
Part Description Pump Motor with Pump Head, Shut Off Valve and Metal Tray SAP Part Description ASSY, PUMP MODULE, ITGN Who Can Order Service Status Active |
Part
22153-60012 – Column Assembly with Heater
+
|
Part Number
22153-60012
📋
Copied
Part Description Column Assembly with Heater SAP Part Description ASSY, COL CMPT, HEATED, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60020 – Power Supply
+
|
Part Number
22153-60020
📋
Copied
Part Description Power Supply SAP Part Description ASSY, POWER SUPPLY, W/ TEC, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60021 – Power Supply for Integrion w/o TEC
+
|
Part Number
22153-60021
📋
Copied
Part Description Power Supply for Integrion w/o TEC SAP Part Description ASSY, POWER SUPPLY, W/O TEC, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60022 – Manual Injection Port
+
|
Part Number
22153-60022
📋
Copied
Part Description Manual Injection Port SAP Part Description ASSY,MANUAL INJECT PORT,ITGN Who Can Order Service Status Active |
Part
22153-60023 – Degas Chamber and Vacuum Pump
+
|
Part Number
22153-60023
📋
Copied
Part Description Degas Chamber and Vacuum Pump SAP Part Description ASSY, DEGAS, ITGN Who Can Order Service Status Active |
Part
22153-60025 – Drain Tube Assembly, with TEC
+
|
Part Number
22153-60025
📋
Copied
Part Description Drain Tube Assembly, with TEC SAP Part Description ASSY, DRAIN TUBES, W TEC Who Can Order Service Status Active Service Manual |
Part
22153-60026 – Drain Tube Assembly, w/o TEC
+
|
Part Number
22153-60026
📋
Copied
Part Description Drain Tube Assembly, w/o TEC SAP Part Description ASSY, DRAIN TUBES, W/O TEC Who Can Order Service Status Active |
Part
22153-60030 – Single Channel Degas Chamber Assembly
+
|
Part Number
22153-60030
📋
Copied
Part Description Single Channel Degas Chamber Assembly SAP Part Description ASSY, SINGLE CHANNEL DEGAS CHAMBER, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60031 – EPM/EGC2 Electrolytic Cable Assembly
+
|
Part Number
22153-60031
📋
Copied
Part Description EPM/EGC2 Electrolytic Cable Assembly SAP Part Description ASSY,CABLE,EGC2/EPM,ITGN Who Can Order Service Status Active |
Part
22153-60046 – Leak Sensor
+
|
Part Number
22153-60046
📋
Copied
Part Description Leak Sensor SAP Part Description ASSY,DET,OPT LEAK,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60056 – CRTC/EPM Mount Assembly
+
|
Part Number
22153-60056
📋
Copied
Part Description CRTC/EPM Mount Assembly SAP Part Description ASSY,CRTC/EPM MOUNT,ITGN Who Can Order Service Status Active |
Part
22153-60061 – Whole Door Assembly
+
|
Part Number
22153-60061
📋
Copied
Part Description Whole Door Assembly SAP Part Description ASSY,DOOR,W LINER,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-60064 – EGC/CRTC Electrolytic Cable Assembly
+
|
Part Number
22153-60064
📋
Copied
Part Description EGC/CRTC Electrolytic Cable Assembly SAP Part Description ASSY,CABLE,EGC1/CRTC Who Can Order Service Status Active |
Part
22153-61001R – 1 Channel Driver Board
+
|
Part Number
22153-61001R
📋
Copied
Part Description 1 Channel Driver Board SAP Part Description ASSY,PCB,ELYT DRVR,1CH,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61002R – 2 Channel Driver Board
+
|
Part Number
22153-61002R
📋
Copied
Part Description 2 Channel Driver Board SAP Part Description ASSY,PCB,ELYT DRVR,2CH,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61004R – Intereconnect PCB
+
|
Part Number
22153-61004R
📋
Copied
Part Description Intereconnect PCB SAP Part Description ASSY,PCB,DET INTERCONNECT,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61006R – Temperature Sensor PCB Assembly
+
|
Part Number
22153-61006R
📋
Copied
Part Description Temperature Sensor PCB Assembly SAP Part Description ASSY,PCB,SNSR,TEMP,ADR 010,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61008R – 3 Channel Driver Board
+
|
Part Number
22153-61008R
📋
Copied
Part Description 3 Channel Driver Board SAP Part Description ASSY,PCB,EG-SRS-CRTC,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61009R – Pump Power Supply Board
+
|
Part Number
22153-61009R
📋
Copied
Part Description Pump Power Supply Board SAP Part Description ASSY,PCB,PWR SPY,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61010R – Column Compartment CTRL Board
+
|
Part Number
22153-61010R
📋
Copied
Part Description Column Compartment CTRL Board SAP Part Description ASSY,PCB,CCB,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61011R – Integrion User Interface PCB
+
|
Part Number
22153-61011R
📋
Copied
Part Description Integrion User Interface PCB SAP Part Description ASSY,PCB,USER INTERFACE,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61013R – Detector Compartment TEC Driver Board
+
|
Part Number
22153-61013R
📋
Copied
Part Description Detector Compartment TEC Driver Board SAP Part Description ASSY,PCB,TEC DRIVER,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-61018R – Pump CPU Board
+
|
Part Number
22153-61018R
📋
Copied
Part Description Pump CPU Board SAP Part Description ASSY,PCB,CPU,PUMP,ITGN Who Can Order Service Status Active Service Manual Notes Referred to as "Pump Motor CPU Board" in Integrion HPIC System Service Manual |
Part
22153-61070R – Main CPU Board
+
|
Part Number
22153-61070R
📋
Copied
Part Description Main CPU Board SAP Part Description ASSY,PCB,CPU,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-6200 – Integrion RFIC Ship Kit
+
|
Part Number
22153-6200
📋
Copied
Part Description Integrion RFIC Ship Kit SAP Part Description ASSY, SHIPKIT, RFIC, INTEGRION Who Can Order Customer and Service Status Active |
Part
22153-62002 – Integrion NON-RFIC Ship Kit
+
|
Part Number
22153-62002
📋
Copied
Part Description Integrion NON-RFIC Ship Kit SAP Part Description KIT, SHIP, INTEGRION Who Can Order Customer and Service Status Active |
Part
22153-62003 – Integrion Ship Kit (RFIC)
+
|
Part Number
22153-62003
📋
Copied
Part Description Integrion Ship Kit (RFIC) SAP Part Description ASSY, SHIPKIT, RFIC, INTEGRION Who Can Order Service Status Active |
Part
22153-62023 – Eluent 2 Channel Add On Kit
+
|
Part Number
22153-62023
📋
Copied
Part Description Eluent 2 Channel Add On Kit SAP Part Description PROD, KIT, EL, 2 CHAN ADD ON, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-62031 – Integrion Wifi Without Tablet Kit
+
|
Part Number
22153-62031
📋
Copied
Part Description Integrion Wifi Without Tablet Kit SAP Part Description PROD, KIT, WiFi WITHOUT TABLET, ITGN, NM Who Can Order Service Status Active Service Manual |
Part
22153-62032 – Integrion Column Oven/RFID Upgrade Kit
+
|
Part Number
22153-62032
📋
Copied
Part Description Integrion Column Oven/RFID Upgrade Kit SAP Part Description PROD, KIT,COLUMN OVEN/RFID UPGRADE, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-62033 – Carbonate Mixer Mounting Bracket Kit
+
|
Part Number
22153-62033
📋
Copied
Part Description Carbonate Mixer Mounting Bracket Kit SAP Part Description Carbonate mixer bracket for Integrion Who Can Order Service Status Active Service Manual |
Part
22153-63004 – Rear Fan Assembly
+
|
Part Number
22153-63004
📋
Copied
Part Description Rear Fan Assembly SAP Part Description ASSY,CABLE,FAN,REAR ENCL,ITGN Who Can Order Service Status Active Service Manual Notes Fan is located on the left side of system |
Part
22153-63009 – TEC Front Fan Assembly
+
|
Part Number
22153-63009
📋
Copied
Part Description TEC Front Fan Assembly SAP Part Description ASSY,CABLE,FAN,TEC FRONT,ITGN Who Can Order Service Status Active Service Manual |
Part
22153-63018 – Door Sensor
+
|
Part Number
22153-63018
📋
Copied
Part Description Door Sensor SAP Part Description ASSY,CABLE,SWITCH,SNSR,DOOR,ITGN Who Can Order Service Status Active |
Part
22153-63032 – Top Door Sensor, with Long Latch Cable
+
|
Part Number
22153-63032
📋
Copied
Part Description Top Door Sensor, with Long Latch Cable SAP Part Description ASSY,CABLE,SWITCH,SNSR,DOOR,TOP,ITGN Who Can Order Service Status Active |
Part
22153-63034 – Rear Fan Assembly (No TEC)
+
|
Part Number
22153-63034
📋
Copied
Part Description Rear Fan Assembly (No TEC) SAP Part Description ASSY,CABLE,FAN,REAR,W OVEN, WO TEC,ITGN Who Can Order Service Status Active Service Manual Notes USe with systems without TEC installed |
Part
22153-98004 – Antenna A RFID PCB
+
|
Part Number
22153-98004
📋
Copied
Part Description Antenna A RFID PCB SAP Part Description ASSY,PCB, RFID ANTENNA A Who Can Order Service Status Active Service Manual |
Part
22153-98005 – Antenna B RFIC PCB
+
|
Part Number
22153-98005
📋
Copied
Part Description Antenna B RFIC PCB SAP Part Description ASSY,PCB, RFID ANTENNA B Who Can Order Service Status Active Service Manual |
Part
22153-98006 – Antenna C RFIC PCB
+
|
Part Number
22153-98006
📋
Copied
Part Description Antenna C RFIC PCB SAP Part Description ASSY,PCB, RFID ANTENNA C Who Can Order Service Status Active Service Manual |
Part
22153-98015 – TEC
+
|
Part Number
22153-98015
📋
Copied
Part Description TEC SAP Part Description TEC ASSY,24V,95W,DET CMPT,ITGN Who Can Order Service Status Active Service Manual |
Part
60-075094 – Tubing Clamp (1/2 PE)
+
|
Part Number
60-075094
📋
Copied
Part Description Tubing Clamp (1/2 PE) SAP Part Description CLAMP,HOSE,1/2,PE Who Can Order Service Status Active |
Part
923686 – 12-position Connector plug
+
|
Part Number
923686
📋
Copied
Part Description 12-position Connector plug SAP Part Description CONN,1X12POS,PLUG,MINI-COMB Who Can Order Customer and Service Status Active |
Category
Pump
+
Part
045721 – Outlet check valve assembly (for primary pump head)
+
|
Part Number
045721
📋
Copied
Part Description Outlet check valve assembly (for primary pump head) SAP Part Description ASSY,CK VLV,OT,SB,2B,GP/GS,PK Who Can Order Customer and Service Status Active Service Manual |
Part
045722 – Inlet check valve assembly (for primary pump head)
+
|
Part Number
045722
📋
Copied
Part Description Inlet check valve assembly (for primary pump head) SAP Part Description ASSY,CK VLV,IN,SB,2B,GP/GS,PK Who Can Order Customer and Service Status Active Service Manual |
Part
045994 – Pump Check Valve Cartridge
+
|
Part Number
045994
📋
Copied
Part Description Pump Check Valve Cartridge SAP Part Description ASSY,CRTG,2-SB BALL,GP40 Who Can Order Service Status Active |
Part
062087 – Purge Valve Body Part
+
|
Part Number
062087
📋
Copied
Part Description Purge Valve Body Part SAP Part Description BODY,VLV,PURGE,PMP,ICS-3000 Who Can Order Service Status Active Service Manual |
Part
062092 – Seal Retainer
+
|
Part Number
062092
📋
Copied
Part Description Seal Retainer SAP Part Description KEEPER,SEAL WASH,PMP Who Can Order Customer and Service Status Active Service Manual |
Part
063382 – Seal wash seal/Priming valve seal
+
|
Part Number
063382
📋
Copied
Part Description Seal wash seal/Priming valve seal SAP Part Description SEAL,W/O ENERGIZER,PURGE,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
074370 – Backup ring
+
|
Part Number
074370
📋
Copied
Part Description Backup ring SAP Part Description RING,BACKUP,SEAL,PUMP,HPA Who Can Order Customer and Service Status Active Service Manual |
Part
075047 – Primary pump head
+
|
Part Number
075047
📋
Copied
Part Description Primary pump head SAP Part Description HEAD,PRIMARY,PUMP,HPA Who Can Order Customer and Service Status Active |
Part
075767 – Seal wash body
+
|
Part Number
075767
📋
Copied
Part Description Seal wash body SAP Part Description ASSY,SEAL WASH, HPA Who Can Order Customer and Service Status Active Service Manual |
Part
075768 – Main seal
+
|
Part Number
075768
📋
Copied
Part Description Main seal SAP Part Description SEAL,.125 PISTON,PUMP,HPA,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
079857 – Piston
+
|
Part Number
079857
📋
Copied
Part Description Piston SAP Part Description PISTON,PMP,.1250,ICS3/5,SAPHIR Who Can Order Customer and Service Status Active Service Manual |
Part
083477 – Primary Pump Head Assembly
+
|
Part Number
083477
📋
Copied
Part Description Primary Pump Head Assembly SAP Part Description HEAD ASSY,PRIMARY,PMP,ICS5+ Who Can Order Service Status Active Service Manual |
Part
22153-60042 – Seal Wash Kit
+
|
Part Number
22153-60042
📋
Copied
Part Description Seal Wash Kit SAP Part Description ASSY, SEAL WASH, ITGN Who Can Order Service Status Active Service Manual |
Part
AAA-062056 – Priming Valve Knob
+
|
Part Number
AAA-062056
📋
Copied
Part Description Priming Valve Knob SAP Part Description ASSY,VLV,PURGE,ICS3/5000 Who Can Order Service Status Active |
Category
Eluent
+
Part
22153-62010 – Eluent Vacuum Degas Kit
+
|
Part Number
22153-62010
📋
Copied
Part Description Eluent Vacuum Degas Kit SAP Part Description PROD, KIT, DEGAS, INTEGRION Who Can Order Customer and Service Status Active Service Manual Notes Includes vacuum pump and deasser chamber |
Part
044105 – High-Pressure Inline Filter
+
|
Part Number
044105
📋
Copied
Part Description High-Pressure Inline Filter SAP Part Description PROD,FLTR,INLINE,10-32,HI PRES Who Can Order Customer and Service Status Active Service Manual |
Part
045987 – End-Line Filter
+
|
Part Number
045987
📋
Copied
Part Description End-Line Filter SAP Part Description FLTR,END-LINE,ELU,1/4-28 UHMW PE Who Can Order Customer and Service Status Active Service Manual Notes Part of the Integrion RFIC and NON-RFIC ship kit. |
Part
062510 – 2-liter Eluent Reservoir
+
|
Part Number
062510
📋
Copied
Part Description 2-liter Eluent Reservoir SAP Part Description ASSY,BTL,2L,ELUENT Who Can Order Customer and Service Status Active Service Manual |
Part
063292 – 4-liter Eluent Reservoir
+
|
Part Number
063292
📋
Copied
Part Description 4-liter Eluent Reservoir SAP Part Description ASSY,BTL,4L,2PORT,HDPE Who Can Order Customer and Service Status Active Service Manual |
Part
075522 – RFIC Eluent Degasser
+
|
Part Number
075522
📋
Copied
Part Description RFIC Eluent Degasser SAP Part Description ASSY,DEGASSER,ANALYT,HP Who Can Order Customer and Service Status Active Service Manual |
Part
078520 – Integrion Regulator Kit
+
|
Part Number
078520
📋
Copied
Part Description Integrion Regulator Kit SAP Part Description PROD,REGULATOR,GAS,ICS4 Who Can Order Customer and Service Status Active Service Manual Notes Used to pressurize eluent reservoirs |
Category
PM Parts
+
Part
074698 – High-pressure valve rebuild kit, 4-port
+
|
Part Number
074698
📋
Copied
Part Description High-pressure valve rebuild kit, 4-port SAP Part Description KIT,REBUILD,400NL, INT LOOP,RHEO,PK Who Can Order Customer and Service Status Active Service Manual |
Part
075973 – High-pressure valve rebuild kit, 6-port
+
|
Part Number
075973
📋
Copied
Part Description High-pressure valve rebuild kit, 6-port SAP Part Description KIT,REBUILD, VLV, 6-PORT,6K Who Can Order Customer and Service Status Active Service Manual |
Part
079054 – High-pressure valve rebuild kit, 10-port
+
|
Part Number
079054
📋
Copied
Part Description High-pressure valve rebuild kit, 10-port SAP Part Description KIT,REBUILD,VLV,10-PORT,6K Who Can Order Customer and Service Status Active Service Manual |
Category
Tools
+
Part
014605 – Open-End Wrench (1/4 x 5/16-in)
+
|
Part Number
014605
📋
Copied
Part Description Open-End Wrench (1/4 x 5/16-in) SAP Part Description TOOL,WRENCH,1/4X5/16 OPEN BOTH ENDS,RoHS Who Can Order Service Status Active |
Part
016388 – 1 mL Syringe
+
|
Part Number
016388
📋
Copied
Part Description 1 mL Syringe SAP Part Description SYRINGE,1CC,DISPOSABLE Who Can Order Customer and Service Status Active |
Part
062336 – Wrench (1/2-in)
+
|
Part Number
062336
📋
Copied
Part Description Wrench (1/2-in) SAP Part Description TOOL,WRENCH,1/2in,OPEN/BOX END Who Can Order Service Status Active |
Part
062338 – Hex Key 3-mm
+
|
Part Number
062338
📋
Copied
Part Description Hex Key 3-mm SAP Part Description TOOL,HEX KEY,3.0MM Who Can Order Service Status Active |
Part
079803 – 10mL Syringe
+
|
Part Number
079803
📋
Copied
Part Description 10mL Syringe SAP Part Description SYRINGE,10CC,NON-STERILE,SLPTP Who Can Order Customer and Service Status Active Service Manual Notes Part of the Integrion RFIC and NON-RFIC ship kit. |
Part
22000-60001 – Universal IC Qualification Test Box II
+
|
Part Number
22000-60001
📋
Copied
Part Description Universal IC Qualification Test Box II SAP Part Description ASSY,IC UNIV QUAL TEST BOX II Who Can Order Service Status Active |
Part
60-078499 – Seal wash seal insertion tool
+
|
Part Number
60-078499
📋
Copied
Part Description Seal wash seal insertion tool SAP Part Description TOOL,INSERTION,SEAL,SEALWASH,ICS4/5 Who Can Order Customer and Service Status Active Service Manual |
Category
Detector
+
Part
014067 – O-ring for pH-Ag/AgCl reference electrode
+
|
Part Number
014067
📋
Copied
Part Description O-ring for pH-Ag/AgCl reference electrode SAP Part Description 1-RING,-012,0.364X.070 EPR Who Can Order Customer and Service Status Active |
Part
030839 – O-ring for end of PdH reference electrode
+
|
Part Number
030839
📋
Copied
Part Description O-ring for end of PdH reference electrode SAP Part Description O-RING,0.362IDx0.568ODx0.103THK,EPR,RoHS Who Can Order Customer and Service Status Active |
Part
036313 – Polishing kit for conventional working electrodes
+
|
Part Number
036313
📋
Copied
Part Description Polishing kit for conventional working electrodes SAP Part Description ASSY,KIT,POLISHING Who Can Order Customer and Service Status Active Notes Includes polishing pads, a bottle or fine polishing compoint, and a bottle of coarse polishing compound |
Part
036318 – Fine polishing compound
+
|
Part Number
036318
📋
Copied
Part Description Fine polishing compound SAP Part Description ASSY,POLISHING CMPD,FINE Who Can Order Customer and Service Status Active |
Part
036319 – Coarse polishing compound
+
|
Part Number
036319
📋
Copied
Part Description Coarse polishing compound SAP Part Description Polishing,Assy, Compound, Coarse Who Can Order Customer and Service Status Active |
Part
036321 – Polishing pads
+
|
Part Number
036321
📋
Copied
Part Description Polishing pads SAP Part Description PAD,POLISHING 8 DIA. Who Can Order Customer and Service Status Active |
Part
045972 – ED cell gasket for conventional working electrodes
+
|
Part Number
045972
📋
Copied
Part Description ED cell gasket for conventional working electrodes SAP Part Description GASKET,CELL,1.0MIL,ED40 Who Can Order Customer and Service Status Active |
Part
060082 – Gold AAA-Direct disposable working electrodes (6 electrodes and 2 gaskets)
+
|
Part Number
060082
📋
Copied
Part Description Gold AAA-Direct disposable working electrodes (6 electrodes and 2 gaskets) SAP Part Description PROD,DE,AU,AAA,PK 6,2GSKT,TSTD Who Can Order Customer and Service Status Active |
Part
060139 – Gold carbohydrate disposable working electrodes (polyester substrate) (6 electrodes and 2 gaskets)
+
|
Part Number
060139
📋
Copied
Part Description Gold carbohydrate disposable working electrodes (polyester substrate) (6 electrodes and 2 gaskets) SAP Part Description PROD,DE,Au ON POLYESTER,PK 6,2GSKT,TSTD Who Can Order Customer and Service Status Active |
Part
061879 – pH-Ag/AgCl reference electrode
+
|
Part Number
061879
📋
Copied
Part Description pH-Ag/AgCl reference electrode SAP Part Description ELECTRODE ASSY,REF,AGCL Who Can Order Customer and Service Status Active Notes Similar in appearance to the AS-AP pH electrode and these electrodes are not interchangeable |
Part
062158 – ED cell polypropylene support block (for use with disposable electrodes)
+
|
Part Number
062158
📋
Copied
Part Description ED cell polypropylene support block (for use with disposable electrodes) SAP Part Description ASSY,BLOCK, BLK PEEK, DE,ED3 Who Can Order Customer and Service Status Active |
Part
063003 – Silver disposable working electrodes (6 electrodes and 2 gaskets
+
|
Part Number
063003
📋
Copied
Part Description Silver disposable working electrodes (6 electrodes and 2 gaskets SAP Part Description PROD,DE,AG,PK 6,2GSKT,TSTD Who Can Order Customer and Service Status Active |
Part
064440 – Platinum disposable working electrodes (6 electrodes and 2 gaskets)
+
|
Part Number
064440
📋
Copied
Part Description Platinum disposable working electrodes (6 electrodes and 2 gaskets) SAP Part Description PROD,DE,PT,PK 6,2GSKT,TSTD Who Can Order Customer and Service Status Active |
Part
066480 – Gold carbohydrate disposable working electrodes (PTFE substrate) (6 electrodes and 2 gaskets)
+
|
Part Number
066480
📋
Copied
Part Description Gold carbohydrate disposable working electrodes (PTFE substrate) (6 electrodes and 2 gaskets) SAP Part Description PROD,DE,AU ON PTFE,PK6,6GSK Who Can Order Customer and Service Status Active |
Part
069336 – Carbon disposable working electrodes (6 electrodes and 2 gaskets)
+
|
Part Number
069336
📋
Copied
Part Description Carbon disposable working electrodes (6 electrodes and 2 gaskets) SAP Part Description PROD,DE,CARBON,PEEK,PK6,6GSKT,TSTD Who Can Order Customer and Service Status Active |
Part
072044 – Electrochemical Detector "ED" cell
+
|
Part Number
072044
📋
Copied
Part Description Electrochemical Detector "ED" cell SAP Part Description Electrochemical Detector Cell Who Can Order Customer and Service Status Active Notes Includes PEEK Yoke Block |
Part
072117 – Gasket for disposable working electrodes, PTFE, 0.001 in (2 gaskets)
+
|
Part Number
072117
📋
Copied
Part Description Gasket for disposable working electrodes, PTFE, 0.001 in (2 gaskets) SAP Part Description PROD,GSKT,W.E.,1-MIL,PTFE,CAP Who Can Order Customer and Service Status Active |
Part
22153-62034 – Dionex Integrion Conductivity Detector (with shipping container)
+
|
Part Number
22153-62034
📋
Copied
Part Description Dionex Integrion Conductivity Detector (with shipping container) SAP Part Description PROD, KIT, CD, INTEGRION, ITGN Who Can Order Customer and Service Status Active Service Manual |
Part
22153-62035 – Dionex Integrion Electrochemical Detector (without cell; with shipping container)
+
|
Part Number
22153-62035
📋
Copied
Part Description Dionex Integrion Electrochemical Detector (without cell; with shipping container) SAP Part Description PROD, KIT, ED, INTEGRION, ITGN Who Can Order Customer and Service Status Active Service Manual |
Category
Fittings
+
Part
024305 – Luer Adapter
+
|
Part Number
024305
📋
Copied
Part Description Luer Adapter SAP Part Description FTG,ADAPTR,1/4-28,FEM LUER Who Can Order Customer and Service Status Active Notes Part of the Integrion RFIC and NON-RFIC ship kit. |
Part
039056 – 1/4-28 coupler
+
|
Part Number
039056
📋
Copied
Part Description 1/4-28 coupler SAP Part Description FTG,UNION,1/4-28 ENDS,.06,P-1 Who Can Order Customer and Service Status Active Notes Used to connect the waste line |
Part
042627 – 10-32 coupler
+
|
Part Number
042627
📋
Copied
Part Description 10-32 coupler SAP Part Description FTG,CPLR,10-32FX10-32F,.02" Who Can Order Customer and Service Status Active Notes Used to connect static mixer to column compartment in Non-RFIC systems and CR-TC eluent outlet to RFIC eluent degasser inlet in RFIC systems |
Part
042772 – 10-32 Fitting plug
+
|
Part Number
042772
📋
Copied
Part Description 10-32 Fitting plug SAP Part Description FTG,PLUG,10-32 BLK,P1 Who Can Order Customer and Service Status Active |
Part
042806 – 1/4-28 to 10-32 coupler
+
|
Part Number
042806
📋
Copied
Part Description 1/4-28 to 10-32 coupler SAP Part Description FTG,CPLR,1/4-28FX10-32,.02" Who Can Order Customer and Service Status Active Notes Used to connect backpressure coil to suppressor regin inlet in CD systems and cell outlet to CR-TC regen inlet in ED systems |
Part
043276 – 10-32 double-cone ferrule
+
|
Part Number
043276
📋
Copied
Part Description 10-32 double-cone ferrule SAP Part Description FTG,FER,DBL CONE,P-1 Who Can Order Customer and Service Status Active Notes Used to connect 0.25 mm (0.010 in) IC black PEEK tubing |
Part
048949 – 1/8 in ferrule
+
|
Part Number
048949
📋
Copied
Part Description 1/8 in ferrule SAP Part Description FTG,FER,FLNGLS,1/8 TFZL,RoHS Who Can Order Customer and Service Status Active Notes Used to connect 1.58 mm (0.062 in) ID PTFE tubing and regen ports in CD systems |
Part
052230 – 1/16 in flangeless fitting nut
+
|
Part Number
052230
📋
Copied
Part Description 1/16 in flangeless fitting nut SAP Part Description FTG,NUT,FLNGLS,1/4-28X1/16,PK,RoHS Who Can Order Customer and Service Status Active Notes Used to connect degas out to shutoff valve in |
Part
062511 – Two-piece ferrule
+
|
Part Number
062511
📋
Copied
Part Description Two-piece ferrule SAP Part Description FTG,FER,TFZ,+PK LK RNG,2PC,RoHS Who Can Order Customer and Service Status Active Notes Used to connect degas out to shutoff valve in |
Part
063505 – 1/4 in NPT to 1/8 in adapter
+
|
Part Number
063505
📋
Copied
Part Description 1/4 in NPT to 1/8 in adapter SAP Part Description FTG,1/8 TUBE X 1/4 MNPT,PRS Who Can Order Customer and Service Status Active Notes Provided in the gas regulator kit |
Part
22000-98001 – 10-32 fitting bolt
+
|
Part Number
22000-98001
📋
Copied
Part Description 10-32 fitting bolt SAP Part Description FTG,BOLT,10-32,1/4 HEX,PEEK,NAT,RoHS Who Can Order Customer and Service Status Active Service Manual Notes Used to connect 0.25 mm (0.010 in) IC black PEEK tubing |
Category
PM Kit
+
Part
040695 – O-ring
+
|
Part Number
040695
📋
Copied
Part Description O-ring SAP Part Description O-RING,-015,.551X.070,EM163-80,RoHS Who Can Order Customer and Service Status Active Service Manual |
Part
062823 – "Next Due Date" PM Label
+
|
Part Number
062823
📋
Copied
Part Description "Next Due Date" PM Label SAP Part Description LABEL,PM KIT,NEXT DUE DATE Who Can Order Service Status Active |
Part
22153-62041 – Integrion HPIC System Preventive Maintenance Kit
+
|
Part Number
22153-62041
📋
Copied
Part Description Integrion HPIC System Preventive Maintenance Kit SAP Part Description ASSY,KIT,PM,INTEGRION Who Can Order Customer and Service Status Active Service Manual |
Category
Standards
+
Part
085324 – High Concentration Carbohydrate Analysis Kit
+
|
Part Number
085324
📋
Copied
Part Description High Concentration Carbohydrate Analysis Kit SAP Part Description ASSY,KIT,BIOFUELS,ED3 Who Can Order Customer and Service Status Active Notes Includes one 62 mil PTFE gasket and modified spacer block |
Category
System Module
+
Part
22153-60305 – Integrion RFIC System, Detector Compartment
+
|
Part Number
22153-60305
📋
Copied
Part Description Integrion RFIC System, Detector Compartment SAP Part Description PROD,INTEGRION, RFIC, DEGAS, OVEN, TEC Who Can Order Customer and Service Status Active |
Part
22153-60305 – Integrion RFIC System, Detector Compartment
+
|
Part Number
22153-60305
📋
Copied
Part Description Integrion RFIC System, Detector Compartment SAP Part Description PROD,INTEGRION, RFIC, DEGAS, OVEN, TEC Who Can Order Customer and Service Status Active |
Part
22153-60306 – Integrion RFIC System, Non-wireless
+
|
Part Number
22153-60306
📋
Copied
Part Description Integrion RFIC System, Non-wireless SAP Part Description PROD,INTEGRION, RFIC, DEGAS, OVEN, NW Who Can Order Customer and Service Status Active |
Part
22153-60306 – Integrion RFIC System, Non-wireless
+
|
Part Number
22153-60306
📋
Copied
Part Description Integrion RFIC System, Non-wireless SAP Part Description PROD,INTEGRION, RFIC, DEGAS, OVEN, NW Who Can Order Customer and Service Status Active |
Category
Tubing
+
Part
014157 – 1.58 mm (0.062 in) ID PTFE tubing
+
|
Part Number
014157
📋
Copied
Part Description 1.58 mm (0.062 in) ID PTFE tubing SAP Part Description TUBING,.062X.125 FEP, RoHS Who Can Order Customer and Service Status Active Notes Used to connect eluent reservoir to shutoff valve or degas inlet, (CD systems) supressor regen ports, (RFIC systems) CR-TC regen ports, (ED systems) cell outlet to CR-TC regen inlet. |
Part
042690 – 0.25 mm (0.010 in) ID black PEEK tubing
+
|
Part Number
042690
📋
Copied
Part Description 0.25 mm (0.010 in) ID black PEEK tubing SAP Part Description TUBING,0.010IDx0.062OD,PK,BLK,RoHS Who Can Order Customer and Service Status Active Notes Used to connect primary and secondary pump heads and injection valve port "P" in systems without a heated column compartment |
Part
042857 – Sample loop, 25 uL
+
|
Part Number
042857
📋
Copied
Part Description Sample loop, 25 uL SAP Part Description ASSY,SAMPLE LOOP,25UL,PK Who Can Order Customer and Service Status Active Service Manual |
Part
042949 – Sample loop, 10 uL
+
|
Part Number
042949
📋
Copied
Part Description Sample loop, 10 uL SAP Part Description ASSY,SAMPLE LOOP,10UL,PK Who Can Order Customer and Service Status Active Service Manual |
Part
045877 – Backpressure coil for 4 mm suppressor
+
|
Part Number
045877
📋
Copied
Part Description Backpressure coil for 4 mm suppressor SAP Part Description ASSY,BKPRESS,4MM,SRS Who Can Order Customer and Service Status Active Notes Used to connect the backpressure coil to suppressor regen inlet for CD systems |
Part
052297 – Orange, 3mm (1/8 in) OD airline tubing
+
|
Part Number
052297
📋
Copied
Part Description Orange, 3mm (1/8 in) OD airline tubing SAP Part Description TUBING,AIRLINE,10FT PU,ORN Who Can Order Customer and Service Status Active Notes Provided in the gas regulator kit |
Part
053765 – Yellow backpressure coil (0.5mL/min, 7 mPa, 1000 psi)
+
|
Part Number
053765
📋
Copied
Part Description Yellow backpressure coil (0.5mL/min, 7 mPa, 1000 psi) SAP Part Description ASSY,COIL,.5ML/MIN,1000PSI,EG4 Who Can Order Customer and Service Status Active Notes Included in the Integrion ship kit |
Part
054410 – 1.02 mm (0.040 in) ID tan PEEK tubing
+
|
Part Number
054410
📋
Copied
Part Description 1.02 mm (0.040 in) ID tan PEEK tubing SAP Part Description TUBING,.040X.062 PK,NTL Who Can Order Customer and Service Status Active Notes Used to connect the shutoff valve outlet to the primary pump inlet check valve and degas to shytoff valve for RFIC-EG systems |
Part
063267 – Pharmed Tubing (0.125 X 0.250)
+
|
Part Number
063267
📋
Copied
Part Description Pharmed Tubing (0.125 X 0.250) SAP Part Description TUBING,0.125IDx0.250OD,PHARMED,RoHS Who Can Order Service Status Active |
Part
063598 – Prime/waste tubing assembly
+
|
Part Number
063598
📋
Copied
Part Description Prime/waste tubing assembly SAP Part Description ASSY,DRAIN,HEAD,PMP,ICS3/5 Who Can Order Customer and Service Status Active Notes Used to connect the seecondary pump head to waste |
Part
063942 – Gas source tubing assembly
+
|
Part Number
063942
📋
Copied
Part Description Gas source tubing assembly SAP Part Description ASSY,TUBING, GAS SOURCE Who Can Order Customer and Service Status Active Notes Provided in the gas regulator kit |
Part
088796 – Viper Tubing Kit for Integrion C/CT
+
|
Part Number
088796
📋
Copied
Part Description Viper Tubing Kit for Integrion C/CT SAP Part Description KIT,VIPER,C/CT INTEGRION Who Can Order Customer and Service Status Active Service Manual |
Part
088797 – Viper Tubing Kit for Integrion with ED
+
|
Part Number
088797
📋
Copied
Part Description Viper Tubing Kit for Integrion with ED SAP Part Description KIT,VIPER,E/ET/ETwTEC,INTEGRON Who Can Order Customer and Service Status Active Service Manual |
Part
088798 – Viper Tubing Kit for Integrion with RFIC
+
|
Part Number
088798
📋
Copied
Part Description Viper Tubing Kit for Integrion with RFIC SAP Part Description KIT,VIPER,XT INTEGRION Who Can Order Customer and Service Status Active Service Manual |
Part
088805 – IC PEEK Viper™ assembly, 0.18 mm (0.007 in), 102 mm (4.0 in)
+
|
Part Number
088805
📋
Copied
Part Description IC PEEK Viper™ assembly, 0.18 mm (0.007 in), 102 mm (4.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 4.0"[102MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the guard column outlet to the separator column |
Part
088806 – Viper assembly, 0.18 mm (0.007 in) ID, 140 mm (5.5 in)
+
|
Part Number
088806
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in) ID, 140 mm (5.5 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 5.5"[140MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the injection valve port "C" to the guard column |
Part
088807 – Viper assembly, 0.18 mm (0.007 in), 165 mm (6.5 in)
+
|
Part Number
088807
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 165 mm (6.5 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 6.5"[165MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the EGC eluent outlet to the CR-TC eluent inlet in RFIC systems |
Part
088808 – Viper assembly, 0.18 mm (0.007 in), 178 mm (7.0 in)
+
|
Part Number
088808
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 178 mm (7.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 7.0"[178MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the separator column to suppressor eluent inlet in CD systems |
Part
088809 – Viper assembly, 0.18 mm (0.007 in), 178 mm (7.0 in)
+
|
Part Number
088809
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 178 mm (7.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 7.0"[178MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect separator column to cell inlet in RFIC systems |
Part
088810 – Viper assembly, 0.18 mm (0.007 in), 229 mm (9.0 in)
+
|
Part Number
088810
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 229 mm (9.0 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 9.0"[229MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect suppressor eluent outlet to CD cell inlet in CD systems |
Part
088811 – Viper assembly, 0.18 mm (0.007 in), 241 mm (9.5 in)
+
|
Part Number
088811
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 241 mm (9.5 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 9.5"[241MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the CR-TC eluent outlet to RFIC eluent degasser inlet |
Part
088813 – Viper assembly, 0.18 mm (0.007 in), 114 mm (4.5 in)
+
|
Part Number
088813
📋
Copied
Part Description Viper assembly, 0.18 mm (0.007 in), 114 mm (4.5 in) SAP Part Description VIPER ASSY,PEEK,.007 ID,4.5 LG DUAL END Who Can Order Customer and Service Status Active Service Manual Notes Used to connect the EGC eluent outlet to the CRD eluent inlet in RFIC systems |
Part
088836 – Viper assembly, 0.18mm (0.007 in), 114 mm (4.5 in)
+
|
Part Number
088836
📋
Copied
Part Description Viper assembly, 0.18mm (0.007 in), 114 mm (4.5 in) SAP Part Description PROD,VIPER ASSY,.007 ID. 5.0"[127MM Who Can Order Customer and Service Status Active Service Manual Notes Used to connect CRD out to Cell in |
Part
22153-40110 – Pre-bent, 0.25 mm (0.010 in) ID black PEEK tubing
+
|
Part Number
22153-40110
📋
Copied
Part Description Pre-bent, 0.25 mm (0.010 in) ID black PEEK tubing SAP Part Description TUBING,BENT,MIXER TO EGC Who Can Order Customer and Service Status Active Service Manual Notes Used to connect static mixter to EGC inlet for RFIC-EG systems |
Part
22153-40111 – Pre-bent, 0.25 mm (0.010 in) ID black PEEK tubing
+
|
Part Number
22153-40111
📋
Copied
Part Description Pre-bent, 0.25 mm (0.010 in) ID black PEEK tubing SAP Part Description TUBING,BENT,MIXER TO HTR Who Can Order Customer and Service Status Active Notes Used to connect static mixer to column compartment in Non-RFIC systems |
Category
Valves
+
Part
061971 – Three-way low-pressure valve
+
|
Part Number
061971
📋
Copied
Part Description Three-way low-pressure valve SAP Part Description ASSY,VALVE,3WAY,LP Who Can Order Customer and Service Status Active Service Manual |
Part
074699 – High-pressure injection valve pod, 4-port
+
|
Part Number
074699
📋
Copied
Part Description High-pressure injection valve pod, 4-port SAP Part Description VLV POD ASSY,400NL, INT LOOP,RHEO,PK Who Can Order Customer and Service Status Active Service Manual |
Part
075971 – High-pressure injection or switching valve pod, 6-port
+
|
Part Number
075971
📋
Copied
Part Description High-pressure injection or switching valve pod, 6-port SAP Part Description VLV POD ASSY,6 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual |
Part
075972 – High-pressure injection or switching valve pod, 10-port
+
|
Part Number
075972
📋
Copied
Part Description High-pressure injection or switching valve pod, 10-port SAP Part Description VLV POD ASSY,10 PORT,RHEO,PK,6K Who Can Order Customer and Service Status Active Service Manual |
Part
079848 – Two-way low-pressure valve
+
|
Part Number
079848
📋
Copied
Part Description Two-way low-pressure valve SAP Part Description ASSY,VALVE,2WAY,LP Who Can Order Customer and Service Status Active Service Manual |
Part
22153-60014 – High-pressure injection or switching valve, 6-port
+
|
Part Number
22153-60014
📋
Copied
Part Description High-pressure injection or switching valve, 6-port SAP Part Description ASSY, VLV, 6-PORT, ITGN Who Can Order Customer and Service Status Active Service Manual |
Part
22153-60015 – High-pressure injection or switching valve, 10-port
+
|
Part Number
22153-60015
📋
Copied
Part Description High-pressure injection or switching valve, 10-port SAP Part Description ASSY, VLV, 10-PORT, ITGN Who Can Order Customer and Service Status Active Service Manual |
Part
22153-62025 – 10-Port Valve Upgrade Kit
+
|
Part Number
22153-62025
📋
Copied
Part Description 10-Port Valve Upgrade Kit SAP Part Description PROD, KIT, 10-PORT VLV, ITGN Who Can Order Service Status Active Service Manual |
Part
22153-62027 – 6-Port Valve Upgrade Kit
+
|
Part Number
22153-62027
📋
Copied
Part Description 6-Port Valve Upgrade Kit SAP Part Description PROD, KIT, 6-PORT VLV, ITGN Who Can Order Service Status Active Service Manual |
Part
60-075353 – 2 Way PEEK Valve (1/4-28)
+
|
Part Number
60-075353
📋
Copied
Part Description 2 Way PEEK Valve (1/4-28) SAP Part Description VALVE,2W,TAKASAGO,12V,PK,1/4-28,RoHS Who Can Order Service Status Active Service Manual |
Sample Loop
+
Category
PEEK Loop
+
Part
042857 – Sample Loop, 25 µL
+
Part
042949 – Sample Loop, 10 µL
+
Part
042951 – Sample Loop, 100 µL
+
















































.png?revision=1)
















.jpg?revision=1)












.png?revision=1)




.jpg?revision=1)















.jpg?revision=1)
.jpg?revision=1)









_ID%252C_blue.jpg?revision=1)














.jpg?revision=1)

.jpg?revision=1)


%252C_tan.jpg?revision=1)



_ID%252C_blue.jpg?revision=1)