Search
- Filter Results
- Location
- Classification
- Include attachments
- https://knowledge1.thermofisher.com/Gallery_Discrete_Analyzers/Discrete_Analyzers_Knowledge/Abnormal_liquid_detection_errorsIssue Abnormal liquid detection errors in Gallery and Gallery Plus analyzers that make the instrument to stop and go to the idle mode abnormally. Environment Gallery Gallery Plus Beermaster Analyzer 6...Issue Abnormal liquid detection errors in Gallery and Gallery Plus analyzers that make the instrument to stop and go to the idle mode abnormally. Environment Gallery Gallery Plus Beermaster Analyzer 6.0 Beermaster Analyzer 7.0 Resolution Downgrade the software to the earlier software version or replace the MOTOR4 PCB dispenser MOTOR4 (position 8 in Gallery and position 8 or 10 in Gallery Plus) to another MOTOR4 PCB with a processor revision D.
- https://knowledge1.thermofisher.com/Gallery_Discrete_Analyzers/Discrete_Analyzers_Knowledge/How_to_remove_a_reagent_rackIssue How do I remove a reagent rack? Environment Gallery Gallery Plus Beermaster Analyzer 6.0 Beermaster Analyzer 7.0 Resolution To remove a rack reagent: Select F3 > REAGENT Select the rack to be re...Issue How do I remove a reagent rack? Environment Gallery Gallery Plus Beermaster Analyzer 6.0 Beermaster Analyzer 7.0 Resolution To remove a rack reagent: Select F3 > REAGENT Select the rack to be removed. Click 'remove rack.' When the light is on, open the cover. Remove the rack. Close the cover.
- https://knowledge1.thermofisher.com/Gallery_Discrete_Analyzers/Discrete_Analyzers_Knowledge/How_to_reduce_the_risk_of_corrosionHow do I reduce the risk of corrosion? NOTE: Special attention should be paid for the daily maintenance of the analyzer. Empty the cuvette waste bin of used cuvettes preferably after each test run or ...How do I reduce the risk of corrosion? NOTE: Special attention should be paid for the daily maintenance of the analyzer. Empty the cuvette waste bin of used cuvettes preferably after each test run or at least at the end of the day while the analyzer is still on. Flush the cuvette waste bin with water and remove any residue. At the end of the day, take the reagents away from the analyzer. Open the analyzer's main vent to ventilate the analyzer and leave the cover open for at least 30 minutes.
- https://knowledge1.thermofisher.com/Gallery_Discrete_Analyzers/Discrete_Analyzers_Knowledge/How_to_clear_rack_informationHow do I clear rack information? To clear the information from all positions from a rack: NOTE: The rack has to be outside of the analyzer when the rack information is handled. Select F3 > REAGENT RAC...How do I clear rack information? To clear the information from all positions from a rack: NOTE: The rack has to be outside of the analyzer when the rack information is handled. Select F3 > REAGENT RACKS. Select the rack from the racks field. Select the rack position. Click 'clear position' to remove the rack position information. NOTE: The function is useful, for example, when the rack has been removed from the analyzer, but the rack information still exists in the user interface.
- https://knowledge1.thermofisher.com/Gallery_Discrete_Analyzers/Discrete_Analyzers_Knowledge/How_to_check_reagent_barcodesIssue How do I check reagent barcodes? Environment Gallery Gallery Plus Beermaster Analyzer 6.0 Beermaster Analyzer 7.0 Resolution To check the content of the reagent rack: Remove the rack from the an...Issue How do I check reagent barcodes? Environment Gallery Gallery Plus Beermaster Analyzer 6.0 Beermaster Analyzer 7.0 Resolution To check the content of the reagent rack: Remove the rack from the analyzer. Ensure the barcodes are properly aligned. Place the rack back on the analyzer. NOTE: The reagents' barcodes are read and the view is updated.