- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/AXP_pump_will_not_turn_onAXP pump will not turn on Verify the power plug is plugged in the back. Go to instruments tab in the Chromeleon console and choose the AXP/pump tab. Find Chromeleon icon in bottom right of computer sc...AXP pump will not turn on Verify the power plug is plugged in the back. Go to instruments tab in the Chromeleon console and choose the AXP/pump tab. Find Chromeleon icon in bottom right of computer screen, arrow near the time. Double click on AXP pump icon. Attachment(s) File Last Modified AXP pump - step 06.png January 12, 2022 AXP pump - step 05.png January 12, 2022 AXP pump - step 04.png January 12, 2022 AXP pump - step 03.png January 12, 2022 AXP pump - step 02.png January 12, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/AXP_Systems/AXP_Operator_Manuals/903029_-_Rev_C_-_Pressure_Transducer_Calibration_ProcedureDescription: This procedure describes the method for re-calibrating pressure-monitoring electronics of Next Generation Pump and Pump Kits. Standalone Next Generation pumps have a two-character class i...Description: This procedure describes the method for re-calibrating pressure-monitoring electronics of Next Generation Pump and Pump Kits. Standalone Next Generation pumps have a two-character class identifier prefix i.e. M1-, MX-, LS-, LD-, LU-, PR-, & CP-Class. They can also be identified by their serial number V prefix e.g. V0123456. AXP Pump Next Generation Pump and Pump Kits Attachment(s): File Last Modified 903029 - Rev C - Pressure Transducer Calibration Procedure.pdf January 07, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/AXP_Systems/AXP_Operator_Manuals/031897_-_Rev_05_-_Dionex_AXP%2F%2FAXP-MS_ManualDescription: Operator Manual Environment: AXP-MS Attachment(s): File Last Modified 031897 - Rev 05 - Dionex AXP AXP-MS Manual.pdf March 14, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/AXP_Systems/AXP_Operator_Manuals/903065_-_Rev_B_-_Next_Generation_Motor_Drive_Board_-_Product_GuideDescription: This document describes in detail the Motor Drive Board that is supplied with Next Generation Pumps and Pump Kits. The Motor Drive Board provides motor drive and pump control for a wide a...Description: This document describes in detail the Motor Drive Board that is supplied with Next Generation Pumps and Pump Kits. The Motor Drive Board provides motor drive and pump control for a wide assortment of standalone pumps and pump kits from Scientific Systems, Inc. Environment: AXP Pump Attachment(s): File Last Modified 903065 - Rev B - Next Generation Motor Drive Board - Product Guide.pdf January 07, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/AXP_Systems/AXP_Operator_Manuals/903062_-_Rev_A_-_External_Control_for_Next_Generation_SSI_PumpsDescription: This document describes in detail the External Control Board that is frequently supplied with Next Generation Pumps and Pump Kits. The External Control Board provides external pump contro...Description: This document describes in detail the External Control Board that is frequently supplied with Next Generation Pumps and Pump Kits. The External Control Board provides external pump control (run, stop, and voltage), output monitoring (fault, relay) and fan power for a wide assortment of pumps from Scientific Systems, Inc. AXP Pump SSI Pumps External Control Board Attachment(s): File Last Modified 903061 - Rev C - Next Generation Control Board - Product Guide.pdf January 07, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/AXP_Systems/AXP_Operator_Manuals/903061_-_Rev_C_-_Next_Generation_Control_Board_-_Product_GuideDescription: This document describes in detail the Control Board that is supplied with Next Generation Pumps and Pump Kits. The Control Board provides user-interface capabilities for the Motor Drive B...Description: This document describes in detail the Control Board that is supplied with Next Generation Pumps and Pump Kits. The Control Board provides user-interface capabilities for the Motor Drive Board, SSI pumps and pump kits, including communications and front-panel display. Environment: AXP Pump Next Generation Control Board Attachment(s): File Last Modified 903061 - Rev C - Next Generation Control Board - Product Guide.pdf January 07, 2022