  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/IC_DIA_Product_Discontinuation_Q1_and_Q2_2024
    After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these pro...After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these products is in keeping with our practice of rationalizing very low demand products and replacing them with new products with improved design and functionality.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/EGC_not_recognized
    On the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select c...On the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select cartridge number to activate, and click Enter. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select serial number to activate, and click Enter. On the Properties tab, click on the drop down arrow in the Mode Value field and select On.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-1X00_ICS2X00_Integrated_IC_Systems/ICS-1X00_ICS2X00_Operator_Manuals/How_to_Activate_a_New_Eluent_Generator_Cartridge
    Description: The attached document describes how to activate a new eluent generator cartridge. Environment: Chromeleon 7 ICS-2000 ICS-2100 ICS-3000 Attachment(s): File Last Modified How to Activate a ...Description: The attached document describes how to activate a new eluent generator cartridge. Environment: Chromeleon 7 ICS-2000 ICS-2100 ICS-3000 Attachment(s): File Last Modified How to Activate a New Eluent Generator Cartridge.PDF January 09, 2022
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Aquion_RFIC/Aquion_Operator_Manuals/031928_-_Rev_07_-_Preventive_Maintenance_Procedure_Dionex_Aquion_and_ICS-1000%2C_ICS-1100%2C_ICS-1500%2C_ICS-1600%2C_ICS-2000%2C_ICS-2100
    Description: This manual describes a preventive maintenance procedure for the Thermo Scientific Dionex Aquion, ICS-1000, ICS-1100, ICS-1500, ICS-1600, ICS-2000, and ICS-2100 Ion Chromatography Systems...Description: This manual describes a preventive maintenance procedure for the Thermo Scientific Dionex Aquion, ICS-1000, ICS-1100, ICS-1500, ICS-1600, ICS-2000, and ICS-2100 Ion Chromatography Systems. Environment: Aquion ICS-1000 ICS-1100 ICS-1500 ICS-1600 ICS-2000 ICS-2100 Attachment(s): File Last Modified 031928 - Rev 07 - Preventive Maintenance Procedure Dionex Aquion and ICS-1000, ICS-1100, ICS-1500, ICS-1600, ICS-2000, ICS-2100 December 30, 2021
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-1X00_ICS2X00_Integrated_IC_Systems/ICS-1X00_ICS2X00_Operator_Manuals/031857-_Rev_03_-_ICS-2000_-_Ion_Chromatography_System_Operators_Manual
    Description: The Dionex ICS-2000 Ion Chromatography System ICS-2000 performs ion analyses using suppressed or non-suppressed conductivity detection. Environment: Dionex ICS-2000 Ion Chromatography Sys...Description: The Dionex ICS-2000 Ion Chromatography System ICS-2000 performs ion analyses using suppressed or non-suppressed conductivity detection. Environment: Dionex ICS-2000 Ion Chromatography System ICS-2000 Attachment(s): File Last Modified 031857- Rev 03 - ICS-2000 - Ion Chromatography System Operators Manual.PDF December 15, 2021
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-1X00_ICS2X00_Integrated_IC_Systems/ICS-1X00_ICS2X00_Operator_Manuals/031858_-_Rev_03_-_ICS-2000_Ion_Chromatography_System_Installation_Manual
    Description: This document provides instructions for the initial installation of the ICS-2000 Ion Chromatography System. Environment: ICS-2000 Ion Chromatography System Attachment(s): File Last Modifi...Description: This document provides instructions for the initial installation of the ICS-2000 Ion Chromatography System. Environment: ICS-2000 Ion Chromatography System Attachment(s): File Last Modified 031858 - Rev 03 - ICS-2000 Ion Chromatography System.PDF December 15, 2021
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Module_Will_Not_Connect_to_Chromeleon
    Ion Chromatography Module Will Not Connect to Chromeleon, Error: Device Is Not Remote All should be plugged in to separate ports, but if you can’t due to availability make sure the detector is plugged...Ion Chromatography Module Will Not Connect to Chromeleon, Error: Device Is Not Remote All should be plugged in to separate ports, but if you can’t due to availability make sure the detector is plugged in separately. If it works on another USB port or a USB isolator, that USB port is bad on your computer. If after all these steps your instrument will still not communicate, please contact technical support and note the firmware and version for each module that will not connect.