- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-6000_HPIC_System/ICS-6000_Operator_Manuals/065340_-_Rev_-_02_ED_User_CompendiumDescription: This Electrochemical Detection (ED) User's Compendium is designed to give users quick and easy access to relevant information for Electrochemical Detectors. Environment: ED (ICS-3000/4000...Description: This Electrochemical Detection (ED) User's Compendium is designed to give users quick and easy access to relevant information for Electrochemical Detectors. Environment: ED (ICS-3000/4000/5000/6000) Integrion HPIC Attachment(s): File Last Modified 065340-Rev-02_Electrochemical-Detection_User_Compendium.pdf July 22, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-5000-5000__HPIC_System/ICS-5000-5000__Operator_Manuals/065484_-_Rev_01_-_Dionex_ICS-5000__Detector_Chromatography_Module_and_Dionex_ICS-5000_Thermal_Compartment_Preventive_Maintenance_ProcedureThe procedure consists of rebuilding each high-pressure valve installed in the Thermo Scientific Dionex ICS-5000+ Detector Chromatography Module DC or the Thermo Scientific Dionex ICS-5000+ Thermal Co...The procedure consists of rebuilding each high-pressure valve installed in the Thermo Scientific Dionex ICS-5000+ Detector Chromatography Module DC or the Thermo Scientific Dionex ICS-5000+ Thermal Compartment TC. Dionex ICS-5000+ Detector Chromatography Module Attachment(s): File Last Modified 065484 - Rev 01 - Dionex ICS-5000+ Detector Chromatography Module and Dionex ICS-5000 Thermal Compartment Preventive Maintenance Procedure.PDF December 16, 2021
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Rear_seal_wash_leaking_errorChromeleon keeps reporting “Error 61: Rear Seal Wash Sensor Malfunction” but no rear seal wash sensor is actually installed. Go to Chromeleon workstation and navigate to “Instrument”. Click command bu...Chromeleon keeps reporting “Error 61: Rear Seal Wash Sensor Malfunction” but no rear seal wash sensor is actually installed. Go to Chromeleon workstation and navigate to “Instrument”. Click command button or click F8 on the keyboard to activate the instrument command window. "Interval" if running eluent other than water through the pump head, that is, manually prepared eluents. "Off" if running water only through the pump head, that is, eluent generation.
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-5000-5000__HPIC_System/ICS-5000-5000__Operator_Manuals/065447_-_Rev_01_-_Dionex_ICS-5000__Ion_Chromatography_System_Installation_InstructionsThe modular design of the Thermo Scientific Dionex ICS-5000+ Ion Chromatography System lets you quickly configure and customize components for a wide range of applications. This manual provides instru...The modular design of the Thermo Scientific Dionex ICS-5000+ Ion Chromatography System lets you quickly configure and customize components for a wide range of applications. This manual provides instructions for initial installation of the components that make up typical IC ion chromatography systems and Reagent-Free IC RFIC systems with eluent generation (RFIC-EG.
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-5000-5000__HPIC_System/ICS-5000-5000__Operator_Manuals/065446_-_Rev_01_-_Dionex_ICS-5000__Ion_Chromatography_SystemDescription: The Thermo Scientific Dionex ICS-5000+ Ion Chromatography System offers a full range of Reagent-Free IC RFIC components. RFIC-EG combines automated eluent generation and self-regenerating...Description: The Thermo Scientific Dionex ICS-5000+ Ion Chromatography System offers a full range of Reagent-Free IC RFIC components. RFIC-EG combines automated eluent generation and self-regenerating suppression to make IC easier and more powerful than ever before. Environment: Thermo Scientific Dionex ICS-5000+ Ion Chromatography System Attachment(s): File Last Modified 065446 - Rev 01 - Dionex ICS-5000+ Ion Chromatography System.PDF December 15, 2021
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/IC_DIA_Product_Discontinuation_Q1_and_Q2_2024After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these pro...After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these products is in keeping with our practice of rationalizing very low demand products and replacing them with new products with improved design and functionality.
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/EGC_not_recognizedOn the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select c...On the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select cartridge number to activate, and click Enter. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select serial number to activate, and click Enter. On the Properties tab, click on the drop down arrow in the Mode Value field and select On.
- https://knowledge1.thermofisher.com/Software_and_Downloads/Chromatography_and_Mass_Spectrometry_Software/Chromeleon/Chromeleon_7_Operator_Manuals/065448_Part_E_-_Rev_7.30a_-_Chromeleon_Operational_Qualification_and_Performance_Qualification_Software_Templates_for_ICS-5000%2C_ICS-5000_%2C_ICS-6000_Analytical_Instruments_-_User's_GuideAttachment(s): File Last Modified 065448 Part E - Rev 7.30a - Chromeleon Operational Qualification and Performance Qualification Software Templates for ICS-5000, ICS-5000+, ICS-6000 Analytical Instrum...Attachment(s): File Last Modified 065448 Part E - Rev 7.30a - Chromeleon Operational Qualification and Performance Qualification Software Templates for ICS-5000, ICS-5000+, ICS-6000 Analytical Instruments - User's Guide.PDF January 05, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/ICS-6000_HPIC_System/ICS-6000_Operator_Manuals/065578_-_Rev_01_-_Dionex_ICS-5000_Plus%2F%2FICS-6000_Capillary_HPIC_System_-_Installation_InstructionsDescription: This manual provides instructions for the initial installation of the Thermo Scientific Dionex ICS-5000+/6000 Capillary HPIC System. Environment: Thermo Fisher Dionex ICS-5000+ Capillary ...Description: This manual provides instructions for the initial installation of the Thermo Scientific Dionex ICS-5000+/6000 Capillary HPIC System. Environment: Thermo Fisher Dionex ICS-5000+ Capillary HPIC System Thermo Fisher Dionex ICS-6000 Capillary HPIC System Attachment(s): File Last Modified 065578-Rev 01 Dionex ICS-5000 Plus and ICS-6000 Capillary HPIC Installation Instructions.pdf June 24, 2022
- https://knowledge1.thermofisher.com/Software_and_Downloads/Chromatography_and_Mass_Spectrometry_Software/Chromeleon/Chromeleon_7_Operator_Manuals/065448_Part_F_-_Rev_7.30a_-_Chromeleon_Operational_Qualification_and_Performance_Qualification_Software_Templates_for_ICS-5000%2C_ICS-5000_%2C_ICS-6000_Capillary_Instruments_-_User's_GuideICS-5000 SP or DP 7.1 SR1 ICS-5000+ SP or DP 7.1 SR1 ICS-5000 EG 7.1 SR1 ICS-5000 CD 7.1 SR1 ICS-5000+ CD 7.1 SR1 ICS-5000 ED 7.1 SR1 ICS-5000+ ED 7.1 SR1 ICS-5000 CD or ED push mode only ICS-5000+ CD...ICS-5000 SP or DP 7.1 SR1 ICS-5000+ SP or DP 7.1 SR1 ICS-5000 EG 7.1 SR1 ICS-5000 CD 7.1 SR1 ICS-5000+ CD 7.1 SR1 ICS-5000 ED 7.1 SR1 ICS-5000+ ED 7.1 SR1 ICS-5000 CD or ED push mode only ICS-5000+ CD or ED push mode only ICS-6000 CD CD or ED push mode only Attachment(s): File Last Modified 065448 Part F - Rev 7.30a - Chromeleon Operational Qualification and Performance Qualification Software Templates for ICS-5000, ICS-5000+, ICS-6000 Capillary Instruments - User's Guide.PDF January 06, 2022
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Module_Will_Not_Connect_to_ChromeleonIon Chromatography Module Will Not Connect to Chromeleon, Error: Device Is Not Remote All should be plugged in to separate ports, but if you can’t due to availability make sure the detector is plugged...Ion Chromatography Module Will Not Connect to Chromeleon, Error: Device Is Not Remote All should be plugged in to separate ports, but if you can’t due to availability make sure the detector is plugged in separately. If it works on another USB port or a USB isolator, that USB port is bad on your computer. If after all these steps your instrument will still not communicate, please contact technical support and note the firmware and version for each module that will not connect.