Searching in
About 29 results
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Storing_the_system_when_not_in_use
    Issue How should ion chromatographs be stored when not in use? Environment Ion Chromatography Resolution Refer to the attached document for recommendations for storing the system when not in use. Atta...Issue How should ion chromatographs be stored when not in use? Environment Ion Chromatography Resolution Refer to the attached document for recommendations for storing the system when not in use. Attachment(s) File Last Modified IC Shutdown- Storing the system when not in use - All Models.pdf January 12, 2022
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/IC_Consumables_and_Accessories/IC_Consumables_and_Accessories_Operator_Manuals/065040_-_Rev_07_-_Product_Manual_For_Disposable_Electrodes
    Description: Disposable electrodes are the latest innovation in electrochemical detection, providing a new level of reproducibility and ease of use. Environment: Disposable gold, silver, platinum, and...Description: Disposable electrodes are the latest innovation in electrochemical detection, providing a new level of reproducibility and ease of use. Environment: Disposable gold, silver, platinum, and carbon electrodes Attachment(s): File Last Modified 065040 - Rev 07 - Product Manual For Disposable Electrodes.PDF December 15, 2021
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Dionex_IC_Reagents_and_Standards
    Issue How to find IC reagents and standards Environment Ion Chromatography Resolution Ic Standards And Reagents | Thermo Fisher Scientific Attachment(s) File Last Modified ps-73062-ic-dionex-standards...Issue How to find IC reagents and standards Environment Ion Chromatography Resolution Ic Standards And Reagents | Thermo Fisher Scientific Attachment(s) File Last Modified ps-73062-ic-dionex-standards-reagents-ps73062-en.pdf December 01, 2022
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Dionex_Quick_Guide%3A_Accessory_List_for_Ion_Chromatography
    Issue I need a part number, e.g., ferrule, bolt, fitting, union, coupler, PEEK sample loop, PEEK tubing part, etc. Environment Ion Chromatography equipment Fittings, adapters, pump parts, tubing, PEEK...Issue I need a part number, e.g., ferrule, bolt, fitting, union, coupler, PEEK sample loop, PEEK tubing part, etc. Environment Ion Chromatography equipment Fittings, adapters, pump parts, tubing, PEEK sample loops, standards Resolution http://tools.thermofisher.com/conten...LPN2497-01.pdf Attachment(s) File Last Modified 86212-DS-IC-Accessories-04May2010-LPN2497-01.pdf September 13, 2022
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Over_Voltage_Error
    Connect tubing from column directly to conductivity cell tubing with 10-32 union (p/n 042627 or 074083), leave back pressure coils installed, direct flow to waste, set column flow to normal flow rate ...Connect tubing from column directly to conductivity cell tubing with 10-32 union (p/n 042627 or 074083), leave back pressure coils installed, direct flow to waste, set column flow to normal flow rate and record system pressure (P2). Connect tubing from the column to the Suppressor’s Eluent In Port, connect tubing from Cell Out to the Suppressor’s Eluent Out Port, reinstall existing Regen Out and Regen In tubing to proper Suppressor Regent Ports.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/IC_DIA_Product_Discontinuation_Q1_and_Q2_2024
    After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these pro...After careful consideration of customer usage, we have decided to discontinue the manufacture and sale of the products outlined in the appendix as of January 30, 2024. The discontinuation of these products is in keeping with our practice of rationalizing very low demand products and replacing them with new products with improved design and functionality.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Reduced_response_in_carbohydrate_applications
    Check the condition of the working electrode and polish to ensure remove any contamination or impurities present if using permanent electrode or replace if using disposable. Check age of reference ele...Check the condition of the working electrode and polish to ensure remove any contamination or impurities present if using permanent electrode or replace if using disposable. Check age of reference electrode and deviation of reference electrode from true pH value. Note: Does rise of issue relate to opening of new reagent bottle or servicing of water source? Perform a 2M NaOH flush to clean system of sample contamination (bypass ED cell and any consumables during this).
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/System_showing_zero_ion_counts
    IC System showing zero Ion counts, (0%) on a new EG cartridge. Find the latest firmware and update it from the service manager in the software apply a a concentration value on the EG and monitor the c...IC System showing zero Ion counts, (0%) on a new EG cartridge. Find the latest firmware and update it from the service manager in the software apply a a concentration value on the EG and monitor the current-voltage value in the software command, check the change in the current value when you change the concentration applied values. If this still showing zero value, EG control board need to be checked and replaced. System not recognizing the EG cartridge because of its firmware
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/EGC_not_recognized
    On the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select c...On the Instrument view, select the Command icon above the ePanel tabs or click the F8 key on the keyboard. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select cartridge number to activate, and click Enter. On the Properties tab, click the drop down arrow in the CartridgeNumber Value field, select serial number to activate, and click Enter. On the Properties tab, click on the drop down arrow in the Mode Value field and select On.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/I_am_not_seeing_my_panels%2C_getting_%E2%80%9C%24%E2%80%9D_instead_of_instrument_name.
    Issue I am not seeing my panels, getting “$” instead of instrument name. Environment Chromeleon 7 Resolution Select the epanel filter dropdown that says "last used" Update the filter from "last used" ...Issue I am not seeing my panels, getting “$” instead of instrument name. Environment Chromeleon 7 Resolution Select the epanel filter dropdown that says "last used" Update the filter from "last used" to "autogenerated" by the drop down icon. Now the dollar signs should not be visible and you should have full control of your instrument.
  • https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Nalgene_filtration_units_for_IC_water_preparation
    Filtration unit for both filtration and degassing of water used for IC eluent preparation reduces particle content as well as dissolved gas. Eluent water should be vacuum filtered through the device a...Filtration unit for both filtration and degassing of water used for IC eluent preparation reduces particle content as well as dissolved gas. Eluent water should be vacuum filtered through the device and cautiously transferred in to eluent bottle. If NaOH or NaOH/NaAcetate eluent is to be prepared, the respective amount of 50% NaOH and/or NaAcetate should be transferred into a defined volume of water in the eluent bottle.