Search
- Filter Results
- Location
- Classification
- Include attachments
- https://knowledge1.thermofisher.com/Lab_Equipment/Lab_Ovens_and_Furnaces/Heating_Equipment_Knowledge/How_to_program_ovensIssue How to program the 6285 or model 282A oven Environment Fisherbrand Isotemp 282A 6285 Resolution Refer to the attached video for instructions Attachment(s) File Last Modified How to program ovens...Issue How to program the 6285 or model 282A oven Environment Fisherbrand Isotemp 282A 6285 Resolution Refer to the attached video for instructions Attachment(s) File Last Modified How to program ovens.wmv January 14, 2022
- https://knowledge1.thermofisher.com/Molecular_Spectroscopy/Fourier_Transform_(FT)_Infrared_(IR)_and_Near_Infrared_(NIR)/FT-IR_and_FT-NIR_Knowledge/Unknown_error%2C_error_number_-2146893813Issue Unknown error, Error number -2146893813 is generated during an archive event Environment RESULT Logged in as a Local User in the administrative group. Resolution Delete the folder: “C:\Users\use...Issue Unknown error, Error number -2146893813 is generated during an archive event Environment RESULT Logged in as a Local User in the administrative group. Resolution Delete the folder: “C:\Users\username\AppData\Roaming\Microsoft\Crypto\RSA”
- https://knowledge1.thermofisher.com/Chromatography/Ion_Chromatography/Ion_Chromatography_Knowledge/Dionex%E2%84%A2_Trap_Column%2F%2FSuppressor_Cleanup_KitUse the Thermo Scientific™ Dionex™ Trap Column/Suppressor Cleanup Kit (PN 059659) to deliver reagent solutions to regenerate and cleanup our trap columns and suppressors. This stand-alone pneumaticall...Use the Thermo Scientific™ Dionex™ Trap Column/Suppressor Cleanup Kit (PN 059659) to deliver reagent solutions to regenerate and cleanup our trap columns and suppressors. This stand-alone pneumatically driven reagent delivery system eliminates the need for using the analytical pump for delivery of concentrated acids, bases or other reagents that can contaminate the IC system.
- https://knowledge1.thermofisher.com/Chromatography/Liquid_Chromatography/LC_Knowledge/How_to_Replace_the_Piston_Seals_and_Support_RingReplace the piston seals of your pump on a regular basis or whenever excessive seal leakage leads to retention time shifts and increased baseline noise. Replace the seal wash seals whenever you remove...Replace the piston seals of your pump on a regular basis or whenever excessive seal leakage leads to retention time shifts and increased baseline noise. Replace the seal wash seals whenever you remove the pump head. Remove the pump head (see “How to Replace the Pump Head”) To access these procedures from your instrument, without the need for an external internet connection, consider adding the Vanquish User Interface to your system.
- https://knowledge1.thermofisher.com/Molecular_Spectroscopy/Molecular_Spectroscopy_Software/OMNIC_Family/OMNIC_Family_Knowledge/Deleting_Library_Spectra_and_Compressing_Libraries_with_OMNIC_DSWhile anyone with Access permission to the Delete function within Library Manage in Thermo Security Administrator, can mark a spectra for deletion and it will be removed from further library searches....While anyone with Access permission to the Delete function within Library Manage in Thermo Security Administrator, can mark a spectra for deletion and it will be removed from further library searches. 2) Users who will need to routinely perform this function should be given full control of the Lib subfolder within the Secure folder structure. (Full control is not needed for the entire Secure folder, just the Lib sub-folder)
- https://knowledge1.thermofisher.com/Chromatography/Liquid_Chromatography/LC_Knowledge/Connecting_the_wash_liquid_linesIf the UltiMate 3000 system includes a LPG-3400 pump or an appropriate SRD-3x00 Solvent Rack, you can degas the wash liquid online via the degasser of the pump or Solvent Rack. First, prepare and inst...If the UltiMate 3000 system includes a LPG-3400 pump or an appropriate SRD-3x00 Solvent Rack, you can degas the wash liquid online via the degasser of the pump or Solvent Rack. First, prepare and install the wash liquid line in the wash liquid reservoir, and then, connect the free end of the tube to the degasser inlet. (The procedure is identical to connecting the solvent lines.
- https://knowledge1.thermofisher.com/Molecular_Spectroscopy/Ultraviolet-Visible_and_Visible_(UV-Vis_and_Vis)_Spectrophotometry/Ultraviolet-Visible_and_Visible_(UV-Vis_and_Vis)_Spectrophotometry_Knowledge/System_failing_the_lamp_test_on_startup.Issue Lamp Failing on startup Environment Spectronic 200e Resolution Lamp failed message most likely means the lamp has failed and needs to be replaced the replacement part number is below. Part numbe...Issue Lamp Failing on startup Environment Spectronic 200e Resolution Lamp failed message most likely means the lamp has failed and needs to be replaced the replacement part number is below. Part number 335423-000 Spare lamps for SPEC200E and GENESYS 20, pkg of 2
- https://knowledge1.thermofisher.com/Lab_Equipment/Centrifuges/Centrifuge_Knowledge/Check_Castor_BrakesWhat is the meaning of the "check castor brakes" error? “Check castor brakes” is NOT an error but rather a safety message to ensure that the centrifuge’s wheels are properly locked in place before sta...What is the meaning of the "check castor brakes" error? “Check castor brakes” is NOT an error but rather a safety message to ensure that the centrifuge’s wheels are properly locked in place before starting a run (see attached image). This message appears only when the centrifuge has just been turned on or the last run is more than two hours ago. So, check the castor brakes before pressing start again to continue with the run.
- https://knowledge1.thermofisher.com/Chromatography/Liquid_Chromatography/LC_Knowledge/Power-UpThe Status LED on the front panel changes to red and a message appears on the autosampler display. If the autosampler is operated from Chromeleon, the message is logged also in the Chromeleon Audit Tr...The Status LED on the front panel changes to red and a message appears on the autosampler display. If the autosampler is operated from Chromeleon, the message is logged also in the Chromeleon Audit Trail. For routine on/off control, use the standby button on the front of the autosampler. Press and hold the button for one second to allow the autosampler to change the mode.
- https://knowledge1.thermofisher.com/Molecular_Spectroscopy/Fourier_Transform_(FT)_Infrared_(IR)_and_Near_Infrared_(NIR)/FT-IR_and_FT-NIR_Knowledge/Part_Number_for_Smart_iTR_Pressure_Tip_for_3-Bounce_Crystal_PlatesIssue The 3-bounce crystal plates for the Smart iTR accessory use a different pressure tip that has a larger Teflon end. Environment Smart iTR accessory Resolution The part number for the replacement ...Issue The 3-bounce crystal plates for the Smart iTR accessory use a different pressure tip that has a larger Teflon end. Environment Smart iTR accessory Resolution The part number for the replacement tip is PKE025-3094
- https://knowledge1.thermofisher.com/Chromatography/Gas_Chromatography/Gas_Chromatography_Knowledge/Low_or_no_peaks_using_TRIPLUS_300HS.Check leaks at the GC side of the TRIPLUS 300HS sample pathway using GC inlet leak test procedures with the TRIPLUS 300HS connected to the inlet. Check leaks at the TRIPLUS 300HS sample side using an ...Check leaks at the GC side of the TRIPLUS 300HS sample pathway using GC inlet leak test procedures with the TRIPLUS 300HS connected to the inlet. Check leaks at the TRIPLUS 300HS sample side using an empty vial following TRIPLUS 300HS leak test procedures. Check blockage of the needle: the vial pressure should drop when the vial is removed from the sampling needle (vial sampling lifter up vs.